• Title/Summary/Keyword: greenhouse test

Search Result 434, Processing Time 0.034 seconds

Structural Analysis Modeling of Disaster Resilient Greenhouse Structures (내재해형 온실구조의 해석을 위한 구조모델)

  • Jung, Ji-Eun;Kim, Dae-Jin;Kim, Hong-Jin;Shin, Seung-Hoon;Kim, Jin-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.1
    • /
    • pp.7-15
    • /
    • 2017
  • This paper presents the results of the parametric study to investigate the effects of several analysis modeling parameters such as support conditions, member connectivities and cable member stiffness on the main mode shapes and natural frequencies of a representative disaster resilient greenhouse structure. In addition, an ambient vibration test was performed on the representative greenhouse structure and its main mode shapes and natural frequencies were obtained. By comparing the experimental and analysis results, a proper analysis modeling method of the representative greenhouse structure was proposed.

A Study on Greenhouse Gas Emission Characteristics of Passenger Car and Van with LPG Fuel According to Displacement and Vehicle Weight (배기량과 차량중량에 따른 LPG 연료를 사용하는 승용 및 승합형 자동차 온실가스 배출 특성에 관한 연구)

  • KIM, HYUNG JUN;LEE, JONG TAE;LIM, YUN SUNG;YUN, CHANG WAN;KEEL, JI HOON;HONG, YOU DEUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.497-502
    • /
    • 2018
  • In Korea, passenger car and van using LPG fuel including taxi constantly increased due to the high cost of fuel. Recently, the emission standard has continuously tightened in the world. In this investigation was conducted the greenhouse gas emission characteristics of LPG vehicles according to the displacement and weight. Exhaust emission characteristics of 13 test LPG vehicles from about 1.0 L to 3.0 L displacements were measured and analyzed by using chassis dynamometer and emission analyzer. It is revealed that the greenhouse gas emission was showed the increasing tendency as the displacement and curb weight increased. Also, greenhouse gas emission of SC03 driving cycle has highest value and that of HWFET driving cycle shows the lowest value.

Application Methodology of Greenhouse Gases Emission Table for Various Types of Roads and Vehicles (도로기하구조 조건에 따른 차량별 온실가스 배출량 산정사례 적용연구 - 맑은 날씨를 기준으로 -)

  • Lee, Jonghak;Choi, Jaisung;Noh, Kwansub;Hu, Hyejung
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.23-31
    • /
    • 2016
  • PURPOSES : This study aimed to offer a greenhouse gases table to assist a road designer in calculating the greenhouse gases for a road environment when making a decision about an alternative road. METHODS : This study developed an operation mode table of greenhouse gases using the MOVES program. Similar factors for Korean vehicles and fuels are reflected in the MOVES program, which was made in the USA. Finally, a paired t-test was conducted to calculate the site data and MOVES data. Through these studies, a methodology was suggested for calculating carbon emissions based on various types of roads alignments. RESULTS : The site results for a passenger truck on the road were statistically significant when the vehicle speed was above 65 km/h. However, a future study will consider factors for various road alignments and vehicles. CONCLUSIONS : This study will contribute to the theoretical basis for reducing carbon emissions from roads by helping road designers make decisions about road alternatives in terms of the road environment.

Analysis on the Effect of the Crown Heating System and Warm Nutrient Supply on Energy Usage in Greenhouse, Strawberry Growth and Production (관부 난방시스템과 온수 양액 공급이 온실 에너지 사용량, 딸기 생육 및 생산성에 미치는 영향 분석)

  • Lee, Taeseok;Kim, Jingu;Park, Seokho;Lee, Jaehan;Moon, Jongpil
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.271-277
    • /
    • 2021
  • In this study, experiments of local heating on crown and supplying warm nutrient for energy saving and improving growth of 'Seolhyang' strawberry were conducted. The temperature of inside and crown in greenhouses which were control (space heating 8℃) and test (space heating 5℃+crown heating) was measured. In the control greenhouse, the average of temperature and humidity in December was 7.1℃, 87.2%, respectively. In the test greenhouse, the average of temperature and humidity in December was 5.7℃, 88.7%. The temperature of crown and inside the bed were 7.9℃, 10.8℃ in control, 9.3℃, 12.7℃ in test. During the test period, the total 16,847×103 kcal of energy was consumed in control greenhouse including space heating. In test greenhouse including space heating, crown heating and warm water supplying, total 9,475.7×103 kcal of energy was consumed. So, energy consumption in test was 43.8% less than in the control. The total yields of strawberry during test period were 412.7g/plant for test greenhouse and 393.3g/plant for control greenhouse respectively.

Stem Rot of Gondre Caused by Rhizoctonia solani AG-2-2(IV)

  • Wan-Gyu Kim;Gyo-Bin Lee;Hong-Sik Shim;Weon-Dae Cho
    • The Korean Journal of Mycology
    • /
    • v.51 no.2
    • /
    • pp.141-146
    • /
    • 2023
  • Stem rot symptoms were observed in Gondre (Cirsium setidens) plants growing in a vinyl greenhouse in Taebaek, Korea during a disease survey in June 2022. The plants presented with dark brown to black rot on the stems at or above the soil line. Severely diseased plants displayed wilt and blight. Disease incidence among these plants ranged from 1 to 5%. Three isolates of Rhizoctonia sp. were obtained from the stem lesions of diseased plants. All isolates were identified as Rhizoctonia solani AG-2-2(IV) based on the morphological and cultural characteristics, results of the anastomosis test, and phylogenetic analysis. The pathogenicity of the isolates to Gondre plants was confirmed using an artificial inoculation test. The lesions induced by the inoculation test were similar to those observed in the investigated vinyl greenhouse. Here, we report a case of R. solani AG-2-2(IV) causing stem rot in Gondre.

A Study on the exhaust gas characteristics of the vehicle gasoline according to the ambient temperature (대기온도에 따른 휘발유 자동차의 배출가스 특성에 관한 연구)

  • Lim, Jae-Hyuk;Kim, Ki-Ho;Kim, Sung-Woo;Lee, Min-Ho;Oh, Sang-Gi
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.47-53
    • /
    • 2015
  • Korea is the geographic location during the summer, the temperature rising to $35^{\circ}C$ and winter temperature is $-15^{\circ}C$ to reduce the air temperature changes, such as relatively large compared to other countries. This increase or decrease of the harmful exhaust gas discharged from automobile substantially inconvenience a significant impact on the active side of the car engine temperature and exhaust gas reducing device receives a large impact on the atmospheric temperature is regulation to be different. However, domestic vehicle emissions test temperature of $20{\sim}30^{\circ}C$ is it does not reflect this situation the actual test temperature to accurately measure the exhaust gas volume of the vehicle is difficult. In this study, domestic automobile exhaust gas test conditions of a test temperature $20{\sim}30^{\circ}C$ various temperatures, including (35, 25, 0, -7, -15, $-25^{\circ}C$) under the two vehicles (2.0L MPI, 2.4 L GDI) as was discussed with respect to the exhaust gas characteristics of the vehicle according to the ambient temperature gas. As a result, domestic emissions test temperature of $25^{\circ}C$ than average conditions were temperature decreases greenhouse gas emissions and increase overall increased by up to 15 times higher. Air temperature and the engine exhaust gas inconvenience a direct effect on the activation temperature required in the reduction unit is determined to be an increase of emissions and greenhouse gases, and also an increase in the variety of lubricants based lubricating and viscosity reduction, such as the engine oil due to the low temperature of these result It is considered that shows the.

Uplift Capacity of Shallow Foundation for Greenhouse (온실용 얕은기초의 인발저항력 검토)

  • Yun, Sung Wook;Choi, Man Kwon;Lee, Si Young;Kang, Dong Hyeon;Moon, Sung Dong;Yu, Chan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.187-195
    • /
    • 2015
  • In this study, a field test of uplift load was carried out using 15 greenhouse foundations fabricated in full scale on a sand soil to examine the uplift capacity of plastic film greenhouse and glasshouse foundations for disasterproof standard. As a result, the maximum uplift capacity of the target greenhouse foundations was shown to be in the range from 11.6kN to 82.4kN according to the differences between the forms and sizes of the foundation. As a result of the examination of the applicability using the field uplift load test result of the theoretical equation proposed for maximum uplift capacity calculation of greenhouse foundations, we found that in general, the conventional theoretical equation for the calculation provided numerical values close to the field test results. However, the soil considered in this study was a sand; thus, in the future, verifying the conventional theoretical equation for the uplift capacity calculation of a cohesive soil would be necessary.

Establishment of Pathogenicity Test Method for Macrophomina phaseolina Causing Soybean Charcoal Rot (콩균핵마름병균에 대한 병원성 검정법 확립)

  • So Hyeon An;Heung Tae Kim
    • Research in Plant Disease
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • The establishment of a laboratory assay and a greenhouse assay was conducted for evaluating the pathogenicity of Macrophomina phaseolina causing soybean charcoal rot established. In the laboratory assay, microsclerotia and hyphae were used as inoculum. In the laboratory assays using microsclerotia as an inoculum, disease incidences of M. phaseolina NSW17-108 and HSM17-034 were higher at 35℃ than 25℃. Of the two isolates NSW17-108 and HSM17-034, the disease incidence of HSM17-034 isolated from diseased sesame is higher than that of NSW17-108 isolated from diseased soybean. When the mycelia of M. phaseolina were used as an inoculum, the disease incidence of NSW17-108 and HSM17-034 at 35℃ exceeded 80% even after only 5 days of inoculation. Even at 25℃, furthermore, that of HSM17-034 exceeded 80% 5 days later. In the pathogenicity assays at a greenhouse, toothpicks where microsclerotia were produced or microsclerotia harvested from potato dextrose agar medium were used as an inoculum. In all greenhouse assays, M. phaseolina NSW17-108 and HSM17-034 showed 40-60% of disease incidences 35-65 days after inoculation with the pathogen, depending on the inoculation method. Between the two isolates, the pathogenicity of HSM17-034 was stronger than that of NSW17-108, and this result was consistent with laboratory assay results. Since the laboratory and greenhouse test methods tested in this study have different advantages and disadvantages depending on each test method, it is thought that the test method that can meet the purpose of the study should be selected and used.

Development of Potassium Impregnated Carbon Absorbents for Indoor CO2 Adsorption (K계열 함침 탄소계 흡착제의 실내 저농도 이산화탄소 흡착성능 강화)

  • Jeong, Se-Eun;Wang, Shuang;Lee, Yu-Ri;Won, Yooseob;Kim, Jae-Young;Jang, Jae Jun;Kim, Hana;Jo, Sung-ho;Park, Young Cheol;Nam, Hyungseok
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.606-612
    • /
    • 2022
  • Relatively high indoor CO2 concentration (>1,000 ppm) has a negative impact on human health. In this work, indoor CO2 adsorbent was developed by impregnating KOH or K2CO3 on commercial activated carbon, named as KOH/AC and K2CO3/AC. Commercial activated carbon (AC) showed relatively high BET surface area (929 m2/g) whereas KOH/AC and K2CO3/AC presented lower BET surface area of 13.6 m2/g and 289 m2/g. Two experimental methods of TGA (2,000 ppmCO2, weight basis) and chamber test (initial concentration: 2,000 ppmCO2, CO2 IR analyzer) were used to investigate the adsorption capacity. KOH/AC and K2CO3/AC exhibited similar adsorption capacities (145~150 mgCO2/g), higher than K2CO3/Al+Si supports adsorbent (84.1 mgCO2/gsample). Similarly, chamber test also showed similar trend. Both KOH/AC and K2CO3/AC represented higher adsorption capacities (KOH/AC: 93.5 mgCO2/g K2CO3/AC: 94.5 mgCO2/gsample) K2CO3/Al+Si supports. This is due to the KOH or K2CO3 impregnation increased alkaline active sites (chemical adsorption), which is beneficial for CO2 adsorption. In addition, the regeneration test results showed both K-based adsorbents pose a good regeneration and reusability. Finally, the current study suggested that both KOH/AC and K2CO3/AC have a great potential to be used as CO2 adsorbent for indoor CO2 adsorption.

Study on Heating Performance of Hybrid Heat Pump System Using Geothermal Source and Solar Heat for Protected Horticulture (시설원예용 지열 및 태양열 이용 하이브리드 히트펌프 시스템의 난방성능에 관한 연구)

  • Jeon, Jong Gil;Lee, Dong Geon;Paek, Yee;Kim, Hyung Gweon
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.49-56
    • /
    • 2015
  • In this study a hybrid heating system based on geothermal source and solar heat was developed in order to save energy for greenhouse heating and its field performance was evaluated. Developed system are composed of following parts: water tank, heat exchanger, heat pump, fan coil unit and heat storage unit. The working performance test was carried out in a greenhouse cultivating oriental orchids being managed by $23^{\circ}C$. Field performance test results showed that average heating coefficient of performance ($COP_h$) was 3.4 for the period from mid-January to mid-March 2013. Heating coefficient of performance ($COP_h$) of developed hybrid heat pump system was more sensitive to water tank temperature than outside air temperature. This study showed that developed hybrid heat pump system has a potential to save the heating costs up to 91% compared to conventional agricultural oil heaters.