• Title/Summary/Keyword: greenhouse structures

Search Result 92, Processing Time 0.022 seconds

The Development of Structural System of Long-span Greenhouse Using the Pre-Engineering Building System (선설계기법을 이용한 장경간 유리온실 구조시스템 개발)

  • Oh, Myoung-Ho;Kim, Yong-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Rural facilities need to be changed to be industrialized and long span structures due to accelerating aging of the rural population. In this study, the optimized structure was developed by applying Pre-Engineered Building System using the tapered member to make that the Korea standard green house has a long span. When considering design load, reasonable values were adapted by reviewing existing design codes. As a result, applying pre-engineered building system was efficient in structural system that has span longer than 16 m. And it was concluded that the increase with the longitudinal span from 4 m to 12 m was more efficient in aspect of steel amount.

A Field Survey on the Structure and Maintenance Status of Pipe Framed Greenhouses (파이프 골조 온실의 구조 및 유지관리실태 조사분석)

  • 남상운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.106-114
    • /
    • 2000
  • An investigation was conducted to get the basic data for establishing maintenance strategy of pipe framed greenhouses. The contents of the investigation consisted of actual state of structures, maintenance status, meteorological disaster, and corrosion characteristics of pipe framework in greenhouses. the number of greenhouses investigated was 108 in total. Most multi-span greenhouses had narrower width and lower height than the standared 1-2W greenhouse, and most of single-span greenhouses were tunnel type. In multi-span greenhouses, the size and interval of frameworks such as rafter, purline, column , and cross beam were mostly suitable, but frameworks of single-span greenhouses were mostly insufficient. After about 7 years in grounds, 8 years in joints, 10 years in bending parts. and 13 years in columns. pipe surface was mostly rusted. Most weak parts in corrosion were pipes in contact with the ground, joints, roll-up shaft pipes, and pipes close to the gutter. Almost all of the greenhouse farmers didn't pay any attention to maintenance affair in a regular interval for pipe framed grenhouses. Many greenhouses have experienced the meteorologicla diaster such as uplift of foundation, partial or complete failure by the hyphoon and/or high winds.

  • PDF

Spatial Distribution and Regional Characteristics of Meteorological Damages to Agricultural Farms in Korea (우리나라 농업기상재해의 공간 분포 및 지역 특성 분석)

  • Song, Inhong;Song, Jung Hun;Kim, Sang Min;Jang, Min Won;Kang, Moon-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.45-52
    • /
    • 2012
  • Along with global warming, ever intensifying weather events have increased damages to agricultural farms and facilities. The objective of this study was to investigate the spatial distribution and regional characteristics of agricultural damages by extreme weather events. Agricultural disaster statistics provided by the National Emergency Management Agency were summed over for a 13-year period from 1998 to 2010 and used for the spatial analysis. Two indices of damage area ration and property damage per unit area were introduced to quantify regional agricultural damages. As the results, farm inundation accounted for the largest area primarily damaged by typhoons with heavy rainfalls. Most property damages to farm lands originated from farm erosion in the alpine regions by localized guerrilla rains. The two major causes of damages to greenhouse and livestock facilities were typhoon with strong wind and winter blizzards. Gangwon was the province of the largest property loss mostly from farm land erosion losses, followed by Gyeongnam, Jeonnam, and Chungnam where losses to greenhouse and livestock facilities were relatively greater. Property loss per unit area was also the greatest for the Gangwon province (4.91 M\/ha), followed by Gyongnam and Chungnam of 2.20 and 1.50 M\/ha, respectively. Unit loss for greenhouse and livestock facilities was 13.3 M\/ha, approximately 13 times greater than that for farm land (1.06 M\/ha). The study findings indicated the importance of reducing highland farm erosion and reinforcing farming facilities structures for agricultural disaster management.

A Study on Sectoral Burden Sharing for Greenhouse Gas Emissions Mitigation (온실가스 감축을 위한 부문별 책임할당방안 연구)

  • Lee, Sang-Youp;Choi, Kyong-Sik
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.171-198
    • /
    • 2009
  • The issue of burden sharing between sectors has become a pertinent national issue with respect tothe establishment of national greenhouse gas (GHG) reduction targets, and the means to achieve these targets. This study explores methods for equitable sectoral allocation to reduce GHGs based on an allocation index taking into account relevant attributes in line with national GHG emissions trends and structures. This paper considered potential for GHG reduction, rate of increase of emissions, and ability to pay as suitable criteria for analysis of each sector. As a result of the analysis, it was found that equitable allocation methods have significantly different burden sharing compared to allocation that considers only potential for GHG reduction. Accordingly, further empirical study on various simulations based on national economic impact will be essential for better policy solutions. This study will contribute to applying national allocation plans in a logical, consistent and transparent manner.

  • PDF

Light-weight Optimum Design of Laminate Structures of a GFRP Fishing Vessel (GFRP 낚시어선의 선체구조 적층판 분석과 경량화 설계)

  • Jang, Jae-Won;Han, Zhiqiang;Oh, Daekyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.495-503
    • /
    • 2019
  • Approximately 90,000 ships are registered in South Korea, and about 80,000 of these ships are used in domestic shipping. Among these, 84% are small ships, such as a fishing vessels that weigh less than 20 tons and are made mostly of an FRP (Fiber Reinforced Plastics). When this fact is taken into account, the greenhouse gas emissions that are released per ton of a composite vessel are sizeable. In this study, the laminated structures of an FRP fishing vessel, many of which currently are being built in Korea, were analyzed by ISO (International Organization for Standardization) and international design rules, and the structures of the hulls are lightweight with optimum glass fiber mass content as determined by the laminate weight minimization algorithm. As a result, it was confirmed that the laminations of the vessels in accordance with the Korean rule could have 6.4% to approximately 11% more design margin compared to the requirements of ISO and other international rules. And the case study of the application of the laminate weight minimization algorithm showed the possibility of reducing the weight of the hull bottom plating by as much as about 19.32% and by as much as about 18.06% in the overall structure.

Field Survey on the Maintenance Status of Greenhouses in Korea (온실의 유지관리 실태조사 분석)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Hyeon Tae;Lee, Si Young;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.148-157
    • /
    • 2014
  • The purpose of this study was to investigate greenhouse maintenance by farms by looking into greenhouses across the nation for greenhouse specification, disaster-resistance greenhouse construction, types and degree of damage due to natural disasters, pre-inspection in case of typhoon or heavy snow forecast, and fire-fighting facilities to prevent a fire. The findings were summarized as follows: as for greenhouse specification, the highest proportion of them were 90 m or longer both in single- and multi-span greenhouses in terms of length; 8 m or wider and 7.0~7.9 m in single- and multi-span greenhouses, respectively, in terms of width; 1.5~1.9 m and 2.0~2.9 m in single-and multi-span greenhouses, respectively, in terms of height; and 3.0~3.9 m and 6 m in single- and multi-span greenhouses, respectively, in terms of diameter. As for disaster-resistance greenhouses, farmers were reluctant to install such greenhouses. The low distribution of disaster-resistance greenhouses was attributed to the greenhouses built dependent on the old practice, the greenhouses already completed, and relatively high construction costs. As for damage by natural disasters, greenhouses were subject to more damage by typhoons than heavy snow. They mainly inspected the ceiling and side windows, entrances, and fixation bands for covering materials in case of typhoon forecast and the heating devices in case of heavy snow forecast. As for repair methods for greenhouse pipe corrosion, they preferred partial replacement to painting and did not use stiffeners for structures to prevent a natural disaster in most cases. As for the maintenance of greenhouse covering materials, most farmers inspected their sealing property but did not clean the coverings for light transmission. The destruction of structural materials can be prevented by eliminating greenhouse covering materials during a typhoon, but they were not able to do so because of the covering material replacement costs and the crops they were growing. The study also examined whether greenhouse farms had fire-fighting facilities to prevent a fire and found that they lacked the perception of greenhouse fire prevention to a great degree.

Calculated external pressure coefficients on livestock buildings and comparison with Eurocode 1

  • Kateris, D.L.;Fragos, V.P.;Kotsopoulos, T.A.;Martzopoulou, A.G.;Moshou, D.
    • Wind and Structures
    • /
    • v.15 no.6
    • /
    • pp.481-494
    • /
    • 2012
  • The greenhouse type metal structures are increasingly used in modern construction of livestock farms because they are less laborious to construct and they provide a more favorable microclimate for the growth of animals compared to conventional livestock structures. A key stress factor for metal structures is the wind. The external pressure coefficient ($c_{pe}$) is used for the calculation of the wind effect on the structures. A high pressure coefficient value leads to an increase of the construction weight and subsequently to an increase in the construction cost. The EC1 in conjunction with EN 13031-1:2001, which is specialized for greenhouses, gives values for this coefficient. This value must satisfy two requirements: the safety of the structure and a reduced construction cost. In this paper, the Navier - Stokes and continuity equations are solved numerically with the finite element method (Galerkin Method) in order to simulate the two dimensional, incompressible, viscous air flow over the vaulted roofs of single span and twin-span with eaves livestock greenhouses' structures, with a height of 4.5 meters and with length of span of 9.6 and 14 m. The simulation was carried out in a wind tunnel. The numerical results of pressure coefficients, as well as, the distribution of them are presented and compared with data from Eurocodes for wind actions (EC1, EN 13031-1:2001). The results of the numerical experiment were close to the values given by the Eurocodes mainly on the leeward area of the roof while on the windward area a further segmentation is suggested.

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

Analysis of Safety Wind Speed and Snow Depth for Single-Span Plastic Greenhouse according to Growing Crops (재배작물별 단동비닐하우스의 안전풍속 및 적설심 분석)

  • Lee, Jong-Won
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.4
    • /
    • pp.280-285
    • /
    • 2013
  • This study supplies basic data to develop a greenhouse model for reducing the damage to single-span greenhouses caused by strong winds and heavy snow. Single-span plastic greenhouses are predominantly used for growing crops in Korea. Thus, the safety wind speeds for single-span greenhouses were calculated and compared with the actual wind speeds and snow depths over a period of 8 years in different regions to analyze the structural safety of single-span greenhouses. The unit wind load and unit snow load were applied to different designs of single-span greenhouse according to the cultivated crop to achieve a structural analysis. As a result, the maximum section force for the wind and snow load was greatest for leaf and root vegetables, where the safety wind speeds for single-span greenhouses according to the cultivated crop were 17.7 m/s(leaf vegetables), 20.2 m/s (fruit vegetables), and 22.3 m/s (root vegetables). Thus, the single-span greenhouses were not found to be safe for the wind load in most regions, except for Hongcheon, Icheon and Sungju. Plus, the safety snow depths for single-span greenhouses according to the crop were 8.8 cm (leaf vegetables), 9.4 cm (fruit vegetables), and 11.8cm (root vegetables). Thus, when comparing the safety snow depths with the actual snow depths, the single-span greenhouses were not found to be safe. Therefore, to improve the safety of single-span greenhouses, the structures need reinforcement by reducing the interval between rafters or increasing the size of the pipes. However, additional research is needed.