• Title/Summary/Keyword: green home system

Search Result 94, Processing Time 0.037 seconds

A Development of Urban Farm Management System based on USN (USN 기반의 도시 농업 관리 시스템 개발)

  • Ryu, Dae-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1917-1922
    • /
    • 2013
  • The objective of this study is developing urban farm management system based on USN for remote monitoring and control. This system makes it easy to manage urban farm and make the database of collected information for to build the best environment for growing crops. For this, we build a green house and installed several types of sensors and camera through which the remote sensing information collected. In addition, building a web page for user convenience and information in real time to enable control. We confirmed experimentally all functions related to stability for a long period of time through field tests such as collection and transfer of information, environmental control in green house. It will be convenient for farmers to grow crops by providing the time and space constraints and a lot of flexibility. In addition, factory, office, home like environment, including facilities for it will be possible to extend.

A Study on Comparison and Analysis of Revision Building Rating System for Environment-friendly Residential Building (국내 친환경 공동주택의 활성화를 위한 개정 건물 성능 평가제도 비교 연구)

  • Park, Kyung Soon;Kim, Chul;Kwon, Moon Hee
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.19-28
    • /
    • 2010
  • As design tools, building performance certification systems can be applied to provide adequate guidelines on design process to create environment-friendly buildings. Domestic certification systems of residential building took effect by doing supply to designers and contractors from affiliated organization of governments in the early 2000s. As a result, Building Energy Rating System, Apartment Performance Rating System, Green Homes and other means to promote green designs have been operated. International trends of applying certification systems were started in the early 1990s as forms of LEED in USGBC, BREEAM in BRE, GBTool Canada. These systems aim to evaluate building performance in line with the Climatic Change Convention and realize sustainable building design. In 2009, residential buildings accounted for the largest portion of the internal real estate market with 67.9 percent according to the National Statistical Office data. And for 18 years since 1991, apartments among constructed residential buildings have ranked top taking up 77.7% as of 2009. Apartment performance evaluations accordingly are to promote to constitution of improving tenant quality of life, the residential environment and saving energy and resources in the internal building market. The purpose of this study is to compare and analyze valuation bases of each sector in evaluation systems of residential buildings at home and abroad to upgrade current systems through reflecting the characteristics of residential buildings. Implementation of this study basically include comparison of valuation bases and partial analysis on properties of rating systems to suggest requisites for improvement in building performance certification.

A Study on the Life Style and Importance for Environment-Friendly Housing of College Students (대학생의 생활양식과 친환경주거 중요도에 관한 연구)

  • Oh, You-Kyung;Kwark, Kyung-Sook
    • Korean Journal of Human Ecology
    • /
    • v.20 no.1
    • /
    • pp.243-255
    • /
    • 2011
  • The purpose of this study was to learn the lifestyles of college students based on the green building certification system. The importance for environmentally friendly housing patterns will be changed and predicted to provide the basis for future residential development. The subjects of this research were 706 college students living in Jeonbuk province. The results of this research were as follows. College students' lifestyles were measured by self-confidence, family orientation, leisure orientation, economic orientation, and a digital directivity by factor analysis. In eco-friendly residential ratings, as the results of analysis according to the land use, the transportation, the energy resources, the environment load, the ecosystems, the interior environment, and the soundproofing of the interior environment came out to be higher than other factors. While coming out to be higher in the lower group in a digital directivity, the life style of the college students mostly came to be higher in the average of importance for environment-friendly housing. This result means that the college students want environment-friendly housing while attaching importance to the convenience of daily life, especially a digital directivity of housing. Thus, when we plan residences in the future, we will have to reflect the environment-friendly housing on the basis of the results of this research, and improve the environment which is contributing to help form college students' characters well.

Development of the Active RFID based Smart Occupancy Detection System (능동형 RFID 기반 지능형 재실감지시스템의 개발)

  • Choi, Yeon-Suk;Park, Byoung-Tae
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.117-123
    • /
    • 2012
  • For an effective energy management in intelligent buildings it is necessary to gather information about position/absence of people and the level of population. In this paper the smart occupancy detection system using the active RFID is developed to satisfy such a demand based on the results of previous research. First of all the design considerations and functions of the system are introduced. In sequence the functions of the system is presented, and then the performance of the developed system is tested and verified through various field tests. The developed core technology can be also applied to other fields such as security, healthcare, smart home, etc.

Understanding and Use of Nutrition Labeling based on One Serving Size Among Female Consumers in Seoul Area (서울지역 여성소비자의 1회 제공량 기준 영양표시의 이용실태)

  • Shin, Doo-Jee;Jung, Kyoung-Wan;Lee, Gui-Chu;Kwon, Kwang-Il;Kim, Jee-Young;Kim, John-Wook;Moon, Gui-Im;Park, Hye-Kyung;Cho, Yoon-Mi;Kim, Yoo-Kyung
    • Journal of the Korean Society of Food Culture
    • /
    • v.25 no.6
    • /
    • pp.725-733
    • /
    • 2010
  • This study examined the understanding and use of information on nutrition labels based on one serving size among female consumers above the age of 20 in Seoul area. According to the survey, 69.9% of respondents were aware of the current system of nutrition labeling based on one serving size, and 51.8% of the respondents expressed their dissatisfaction with the system because the nutrition labels were difficult to understand or appeared unreliable. The nutrition label literacy of the consumers varied with respect to different packaging units. The respondents were likely to be less accurate in calculating the expected caloric intake when only portions of a multi-serving package were used. Initially 69.0% of respondents reported that they had read the nutrition label before purchasing a product but 91.9% of respondents said that they would check the label after learning how to read the label properly. It is very important to make consumers aware that the labels are very reliable sources of nutrition information. A public education campaign on the use of nutrition labels should focus on developing the consumers' ability and skills in using the label information when choosing foods.

A Study on Korean Green Tea(II) -Analysis of free Amino Acid and Mineral- (한국산(韓國産) 녹다(緣茶)에 대(對)한 연구(硏究) (제 II 보) -Free amino Acid와 무기성분(無機成分)에 대(對)하여-)

  • Jung, Jai-Kie;Yu, Choon-Hie;Chung, Tai-Young;La, Sang-Moo
    • Journal of Nutrition and Health
    • /
    • v.6 no.3
    • /
    • pp.17-20
    • /
    • 1973
  • Quantitative analysis was achieved by gas-liquid chromatographic method (GLC) with a single column system of OV-17 for 16 of free amino acids in Korean green tea and the contents of mineral in it was determined by atomic absorption flame emission. The results are summarized as follows: 1) Korean green tea contained Mn 1% or over out of the total ash content and $0.05{\sim}0.20%$ in the water extraction, as the major mineral. 2) Ba, Cr, Ni, Pb and V were analyzed also by small quantities relatively and Co, Tin and Ywere not detected in the water extraction. 3) GLC indicated the presence of 16 components in free ammo acids. 4) The quantities of free amino acids in Korean green tea were determined $2.96{\sim}6.61%$ Alanine, $1.01{\sim}l.89mg%$ Glycine, $2.07{\sim}7.81mg%$ Valine, $1.27{\sim}8.76mg%$ Leucine and Isoleucine, $94.31{\sim}316.27mg%$ Threonine, $9.10{\sim}39.91mg%$ Serine, $2.18{\sim}36.76mg%$ Hydroxyproline, $2.72{\sim}5.90mg%$ Proline, $39.64{\sim}70.02mg%$ Aspartic Acid, $25.93{\sim}101.28mg%$ Glutamic Acid and Lysine, $8.32{\sim}18.30mg%$ Phenylalanine and Tyrosine in trace amount. 5) The total free amino acid contents in Korean green tea ranged from 207.24mg% to 516.06mg% and Moo-Deoung tea contained outstandingly high, 516 mg% or over.

  • PDF

Development of a Moving Monitor System for Growing Crops and Environmental Information in Green House (시설하우스 이동형 환경 및 생장 모니터링 시스템 개발)

  • Kim, Ho-Joon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.3
    • /
    • pp.285-290
    • /
    • 2016
  • In rural area, our farmers confront decreasing benefits owing to imported crops and increased cost. Recently, the government encourage the 6th Industry that merges farming, rural resources, and information and communication technology. Therefor the government makes an investment in supplying 'smart greenhouse' in which a farmer monitor growing crops and environment information to control growing condition. The objective of this study is developing an Moving Monitor and Control System for crops in green House. This system includes a movable sensing unit, a controlling unit, and a server PC unit. The movable sensing unit contains high resolution IP camera, temperature and humidity sensor and WiFi repeater. It rolls on a rail hanging beneath the ceiling of a green house. The controlling unit contains embedded PC, PLC module, WiFi router, and BLDC motor to drive the movable sensing unit. And the server PC unit contains a integrated farm management software and home pages and databases in which the images of crops and environment informations. The movable sensing unit moves widely in a green house and gathers lots of information. The server saves these informations and provides them to customers with the direct commercing web page. This system will help farmers to control house environment and sales their crops in online market. Eventually It will be helpful for farmers to increase their benefits.

Shear Performance of Hybrid Post and Beam Wall System Infilled with Structural Insulation Panel (SIP)

  • Shim, Kug-Bo;Hwang, Kweon-Hwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.405-413
    • /
    • 2010
  • A hybrid post and beam shear wall system with structural insulation panel (SIP) infill was developed as a part of a green home 'Han-green' project through post and beam construction for contemporary life style. This project is on-going at the Korea Forest Research Institute to develop a new building system which improves Korean traditional wet-type building system and stimulates industrialized wood construction practice with pre-cut system. Compared to the traditional wet-type infill wall components, the hybrid wall system has benefits, such as, higher structural capacity, better thermal insulation performance, and shorter construction term due to the dry-type construction. To build up the hybrid wall system, in previous, SIP infill wall components can be manufactured at factory, and then inserted and nailed with helically threaded nails into the post and beam members at site. Shear performance of the hybrid wall system was evaluated through horizontal shear tests. The SIP hybrid wall system showed higher maximum shear strength, initial stiffness, ductility, yield strength, specified strength, and the specified allowable strength than those of post and beam with light-frame wall system. In addition to this, the hybrid wall system can provide speedy construction and structural and functional advantages including energy efficiency in the building system.

A Study for Space-based Energy Management System to Minimizing Power Consumption in the Big Data Environments (소비전력 최소화를 위한 빅데이터 환경에서의 공간기반 에너지 관리 시스템에 관한 연구)

  • Lee, Yong-Soo;Heo, Jun;Choi, Yong-Hoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.229-235
    • /
    • 2013
  • This paper proposed the method to reduce and manage the amount of using power by using the Self-Learning of inference engine that evolves through learning increasingly smart ways for each spaces with in the Space-Based Energy Management System (SEMS, Space-based Energy Management System) that is defined as smallest unit space with constant size and similar characteristics by using the collectible Big Data from the various information networks and the informations of various sensors from the existing Energy Management System(EMS), mostly including such as the Energy Management Systems for the Factory (FEMS, Factory Energy Management System), the Energy Management Systems for Buildings (BEMS, Building Energy Management System), and Energy Management Systems for Residential (HEMS, Home Energy Management System), that is monitoring and controlling the power of systems through various sensors and administrators by measuring the temperature and illumination.

An Evaluation of Indoor Thermal Environment for Zero-Carbon Green Home according to the Operation Conditions in Summer (제로카본 그린홈의 여름철 운영조건에 따른 실내 열환경 평가)

  • Yu, Jung yeon;Cho, Dong woo;Kim, Kee Han
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.25-36
    • /
    • 2020
  • The Korean government has a plan to mandate zero-energy buildings in 2020 for public and 2025 for private buildings. In order to design a zero-energy building, insulation and airtightness, which are the most basic elements of passive house technology, are required, and the government has been accomplished this through step-by-step strengthening of related standards. In passive house with high thermal insulation and airtightness performance, the heat introduced into the building through solar radiation can be stored for a long time to keep the inside warm during winter. On the other hand, during summer, heat introduced into the building cannot be easily released to outside, so it is necessary to actively block solar radiation and high temperature outdoor air to prevent an increase of indoor temperature. Therefore, this study aims to derive an appropriate operation condition of passive house to maintain the indoor temperature at an suitable level according to the ventilation methods and solar shading conditions. As a result, under the conditions that the outdoor temperature was 28℃ or less, the ventilation using a heat recovery ventilation system at daytime and natural ventilation at nighttime were selected for the most appropriate operation method. In addition, in the case of solar shading, it was found that blocking solar radiation at daytime using the blind and open the blind at nighttime to ensure natural ventilation were selected for the most appropriate solar shading condition.