• 제목/요약/키워드: gray scale image

검색결과 256건 처리시간 0.029초

뇌 자기공명영상에서 Heavily T2 FLAIR와 DWI 기법의 영상비교 (Image Comparison of Heavily T2 FLAIR and DWI Method in Brain Magnetic Resonance Image)

  • 구은회
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.397-403
    • /
    • 2023
  • The purpose of this study is to obtain brain MRI images through Heavenly T2 FLAIR and DWI techniques to find out strengths and weaknesses of each image. Data were analyzed on 13 normal people and 17 brain tumor patients. Philips Ingenia 3.0TCX was used as the equipment used for the inspection, and 32 Channel Head Coil was used to acquire data. Using Image J and Infinity PACS Data, 3mm2 of gray matter, white matter, cerebellum, basal ganglia, and tumor areas were set and measured. Quantitative analysis measured SNR and CNR as an analysis method, and qualitative analysis evaluated overall image quality, lesion conspicuity, image distortion, susceptibility artifact and ghost artifact on a 5-point scale. The statistical significance of data analysis was that Wilcox-on Signed Rank Test and Paired t-test were executed, and the statistical program used was SPSS ver.22.0 and the p value was less than 0.05. In quantitative analysis, the SNR of gray matter, white matter, cerebellum, basal ganglia, and tumor of Heavily T2 FLAIR is 41.45±0.13, 40.52±0.45, 41.44±0.51, 40.96±0.09, 35.28±0.46 and the CNR is 15.24±0.13, 16.75±0.23, 16.28±0.41, 15.83±0.17, 16.63±0.51. In DWI, SNR is 32.58±0.22, 36.75±0.17, 30.21±0.19, 35.83±0.11, 43.29±0.08, and CNR is 13.14±0.63, 14.21±0.31, 12.95±0.32, 11.73±0.09, 17.56±0.52. In normal tissues, Heavenly T2 FLAIR obtained high results, but in disease evaluation, high results were obtained at DWI, b=1000 (p<0.05). In addition, in the qualitative analysis, overall image quality, lesion conspicuity, image distortion, susceptibility artifact and ghost artifact aspects of the Heavily T2 FLAIR were evaluated, and 3.75±0.28, 2.29±0.24, 3.86±0.23, 4.08±0.21, 3.79±0.22 values were found, respectively, and 2.53±0.39, 4.13±0.29, 1.90±0.20, 1.81±0.21, 1.52±0.45 in DWI. As a result of qualitative analysis, overall image quality, image distortion, susceptibility artifact and ghost artifact were rated higher than DWI. However, DWI was evaluated higher in lesion conspicuity (p<0.05). In normal tissues, the level of Heavenly T2 FLAIR was higher, but the DWI technique was higher in the evaluation of the disease (tumor). The two results were necessary techniques depending on the normal site and the location of the disease. In conclusion, statistically significant results were obtained from the two techniques. In quantitative and qualitative analysis, the two techniques had advantages and disadvantages, and in normal and disease evaluation, the two techniques produced useful results. These results are believed to be educational data for clinical basic evaluation and MRI in the future.

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.

항공 영상 융합의 성능 향상을 위한 적응 가이디드 필터 (An Adaptive Guided Filter for Performance Improvement of Aviation Image Fusion)

  • 김선영;강창호;박찬국
    • 한국항공우주학회지
    • /
    • 제44권5호
    • /
    • pp.407-415
    • /
    • 2016
  • 본 논문에서는 최적의 항공 영상 융합을 위하여 적응 가이디드 필터 기반 알고리즘을 제안하였다. 제안한 적응 가이디드 필터는 가이디드 필터 설계 요소 중에서 정규화 파라미터 값을 입력된 영상 특성에 따라서 조절하고 PSNR (peak signal to noise ratio)을 미리 정해둔 값으로 유지한다. 제안한 방법은 입력 영상의 특성에 관계없이 미리 정한 PSNR을 유지하는 범위 내에서 잡음을 제거하므로 최적의 영상 융합 성능의 결과를 가져올 수 있다. 필터 성능은 시뮬레이션을 통해 검증하였고, 기존에 많이 사용되고 있는 영상융합 품질 파라미터를 이용하여 분석하였다.

Iterative Fourier Transform Algorithm Based on the Segmentation of Target Image for a High-Speed Binary Spatial Light Modulator

  • Im, Yeonsu;Kim, Hwi;Hahn, Joonku
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.149-153
    • /
    • 2015
  • A digital micro-mirror device (DMD) has the potential to modulate an incident wave with high speed, and the application for holographic display has been studied by many researchers. However, the quality of reconstructed image isn't good in comparison with that from a gray-scale amplitude-only hologram since it is a binary amplitude-only spatial light modulator (SLM). In this paper, we suggest a method generating a set of binary holograms to improve the quality of the reconstructed image. Here, we are concerned with the case for which the object plane is positioned at the Fourier domain of the plane of the SLM. In this case, any point in the Fourier plane is related to all points in the hologram. So there is a chance to generate a set of binary holograms illuminated by incident wave with constant optical power. Moreover, we find an interesting fact that the quality of reconstructed image is improved when the spatial frequency bandwidth of the binary hologram is limited. Therefore, we propose an iterative segmentation algorithm generating a set of binary holograms that are designed to be illuminated by the wave with constant optical power. The feasibility of our method is experimentally confirmed with a DMD.

컬러 불변 특징과 광역 특징을 갖는 확장 SURF(Speeded Up Robust Features) 알고리즘 (Extended SURF Algorithm with Color Invariant Feature and Global Feature)

  • 윤현섭;한영준;한헌수
    • 대한전자공학회논문지SP
    • /
    • 제46권6호
    • /
    • pp.58-67
    • /
    • 2009
  • 대응점 정합은 컴퓨터 비전에서 중요한 작업 중에 하나지만 스케일, 조명, 시점이 변한 환경에서 대응점을 찾는 과정은 매우 어렵다. 대응점 정합 알고리즘인 SURF(Speeded Up Robust Features) 기법은 SIFT(Scale Invariant Feature Transform) 기법에 비해 정합 속도가 매우 빠르고 비슷한 정합 성능을 보여 널리 사용되고 있다. 하지만 SURF 기법은 흑백 영상과 지역 공간정보를 사용하기 때문에 유사한 패턴이 존재하는 영상에서 대응점의 정합 성능이 매우 떨어진다. 이런 문제점을 해결하기 위해 본 논문에서는 강인한 컬러 특징 정보와 광역적 특징 정보를 이용하는 확장 SURF 알고리즘을 제안한다. 제안하는 알고리즘은 비슷한 패턴이 존재하더라도 색상정보과 광역 공간 정보를 추가로 사용되기 때문에 대응점 매칭 성능을 크게 향상시킨다. 본 논문에서는 제안하는 방법의 우수성을 조명과 시점이 변화하고 유사한 패턴들을 갖는 영상들에 적용하여 기존의 방법들과 비교 실험함으로서 입증하였다.

효율적인 엔트로피부호화를 위한 명암도 등급 이미지의 전처리 기법 (A Preprocessing Technique of Gray Scale Image for Efficient Entropy Coding)

  • 김선자;한득수;박정만;유강수;이종하;곽훈성
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2005년도 춘계학술발표대회
    • /
    • pp.805-808
    • /
    • 2005
  • 엔트로피부호화(entropy coding)는 텍스트와 같은 일반적인 데이터들을 효율적으로 압축하는 반면에, 이미지 데이터들에 대해서는 그 성능이 다소 저하된다. 본 논문에서는 이러한 단점을 개선시키기 위한 효율적인 전처리기법(preprocessing technique)을 소개한다. 제안한 전처리기법은 입력된 명암도 등급 이미지를 무손실 압축하기 이전에, 이미지 내에서 인접한 명암도 값들의 발생빈도(occurrence frequency)를 조사한다. 다음으로 각 픽셀 쌍들의 명암도 값들을 발생빈도에 기반한 순서화된 값(ordered number)들로 대체시킨 후, 최종적으로 엔트로피부호화에 의한 압축을 수행한다. 이와 같은 단계들을 거치면서 이미지 데이터의 통계적인 특성(statistical feature)이 보다 강화되기 때문에, 엔트로피부호화에서의 무손실 압축 성능을 효율적으로 개선시킬 수 있다. 실험을 통하여 256 명암도 등급 이미지들을 산술부호화와 허프만부호화를 사용하여 압축한 결과, 제안한 전처리기법이 압축 후 비트율(bit rate)을 최대 37.49%까지 감소시켰음을 확인하였다.

  • PDF

진단 초음파 영상 처리를 위한 적응 Pseudomedian 필터 (An Adaptive Pseudomedian Filter for the Ultrasound Medical Image Processing)

  • 어진우;허은석
    • 전기전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.271-280
    • /
    • 2003
  • 본 논문에서는 진단 초음파 영상에서의 스펙클 잡음의 영향을 줄여 대상물체를 효율적으로 분리하는 방법을 제안하였다. 스페클 잡음을 제거하기 위하여 전처리 과정에서 gray scale opening 연산을 실행 후 윈도우내에서 임의의 픽셀에서의 분산을 계산하여 균일 영역과 경계 영역을 구분하고, 구분된 각 영역에 대해 윈도우 크기가 다른 pseudomedian 필터를 사용하였다. (본 논문에서 적응 pseudomedian 필터라 부름.) 영역 구분 없이 같은 크기의 윈도우를 사용한 경우보다 필터링 시간이 단축되며, 스페클 잡음을 충분히 제거할 수 있었다. 필터의 성능을 평가하기 위하여, 제안한 필터를 기존의 영상처리 필터의 결과에 대한 PSNR과 비교하여 우수하다는 것을 입증하였다.

  • PDF

스포츠 영상 내에서 자동적인 가상 광고 삽입을 위한 다층퍼셉트론 기반의 저정보 영역 검출 (Low-Informative Region Detection based on Multi-Layer Perceptron for Automatical Insertion of Virtual Advertisement in Sports Image)

  • 정재영;김종하
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권1호
    • /
    • pp.71-77
    • /
    • 2017
  • 가상광고는 컴퓨터 그래픽을 이용하여 스포츠영상과 같은 미디어제작영상에 제품의 이미지, 로고, 선전문구 등을 삽입하는 광고기법이다. 최근 영상처리 기술과 컴퓨터 성능의 상승으로 인해 스포츠영상에 가상광고를 삽입하기 위한 기술적인 요소가 충족되어 영상 내에 가상광고의 삽입이 활발하게 진행되고 있다. 또한 자동적인 가상광고 삽입을 위한 영상 처리 기술이 가상광고 영역에서 중요한 연구 분야로 자리 잡고 있다. 이에 본 논문에서는 스포츠 영상 내에서 자동적으로 가상광고를 삽입하기 위해 영상처리 기법과 기계학습을 활용하여 저정보 영역을 추출하는 방법을 제안한다. 제안 방법은 영상의 밝기 정도를 히스토그램을 통해 분석하고 기계학습 방법을 활용하여 저정보 영역을 추출한다.

Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1) (Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species)

  • 송정일;김한슬
    • 보존과학회지
    • /
    • 제37권3호
    • /
    • pp.220-231
    • /
    • 2021
  • 문화재 방사선 비파괴 투과 조사 방식은 이미지플레이트(Image Plate, IP)를 사용하는 디지털 방사선영상시스템(Computed Radiography, CR)이 도입되면서 필름방식의 아날로그 이미지에서 점차 디지털 이미지로 교체되고 있다. 방사선 비파괴 투과 조사의 이미지 품질은 촬영 조건(관전압, 관전류, 노출시간), 영상 획득 매체, 촬영 거리, 유물의 두께 등이 영향을 미친다. 이 논문에서는 목재 문화재에 주로 사용되는 수종(소나무, 밤나무, 은행나무, 상수리나무)에 X선 선원의 투과 특성을 GE사(社)의 CR 영상 시스템을 통해 획득된 이미지의 그레이 스케일(Gray Scale)을 분석한 후 신호 대 잡음비(signal to noise ratio) 및 대조도를 평가하고, 이중-선 상질계(Duplex-wire image quality indicator), 구형파 차트(line-pair gauges), 선형 식별계(Image Quality Indicator)를 이용하여 이미지를 분석하였다.

점 행렬을 이용한 새로운 부분 영상 검색 기법 (A Novel Sub-image Retrieval Approach using Dot-Matrix)

  • 김준호;강경민;이도훈
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.1330-1336
    • /
    • 2012
  • 영상 검색 방법은 텍스트 기반, 내용 기반, 영역 기반 영상 검색, 부분 영상 검색 방법 등 다양한 연구가 이루어지고 있다. 그 중에 부분 영상 검색은 질의 영상을 포함하는 대상 영상을 찾는 문제이다. 본 논문에서는 생물정보학에서 사용하는 점 행렬 방법을 이용한 새로운 부분 영상 검색 방법을 제안한다. 점 행렬은 두 DNA 서열 간에 유사도를 시각화하는 방법으로써 영상 검색에 적용하여 두 영상 간에 유사도를 비교하는 문제로 재정의한다. 이 알고리즘을 적용하기 위해서 이차원 배열 정보인 영상을 일차원 명암도 영상으로 변환한다. 두 일차원 명암도 영상을 정렬하여 생성된 점 행렬을 이용하여 부분 영상 후보 영역을 생성한다. 실험에는 10 개의 대상 영상과 대상 영상의 부분을 복사한 영상, 축소한 영상, 확대한 영상으로 5종류의 질의 영상을 사용하였다.