• Title/Summary/Keyword: grass concrete

Search Result 37, Processing Time 0.037 seconds

An Experimental Study of Surface Materials for Planting of Building Surface by the Radiant Heat Balance Analysis in the Summer (하절기 실험을 통한 건물녹화용 피복재료의 복사수지 해석)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.71-80
    • /
    • 2010
  • This study carried out to understand the thermal characteristics of various surface material which compose the city through the observation in the summer. To examine passive cooling effect of planting of building, it is arranged four different materials that is natural grass, grass block, concrete slab and artificial grass. The results of this study are as follows; (1) Natural grass and grass block show the lower surface temperature because of the structures of leaf can do more thermal dissipation effectively. (2) There is little surface temperature between artificial grass and concrete. But there is little high surface temperature difference between natural grass and concrete because of latent heat effect. (3) The concrete can play a role of the tropical nights phenomenon as high heat capacity of concrete compare with other materials. (4) It is nearly same color in artificial grass and natural grass but there is large difference between natural grass and artificial grass at albedo. There is different albedo in near infrared ray range. (5) A short wave radiation gives more effect at the globe temperature than long wave radiation. (6) The artificial turf protected the slab surface temperature increase in spite of thin and low albedo materials.

Hydraulic Model Test and Numerical Analysis of Grass Concrete in River Environment (자연형 호안공법의 그라스콘의 수리모형실험 및 수치해석 연구)

  • Jang, Suk-Hwan;Park, Sung-Bum;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1244-1248
    • /
    • 2007
  • This study aims at investigating the in situ applying grass concrete system in river environments which widely used nowadays and reviewing the effect and flow resistance for grass concrete structure through the physical experiments by hydraulic model test and developing application method in river bed which has rigid flood resistance. Grass concrete structure has been independently tested under high velocity flow under the super critical condition, as well as sud critical flow measuring velocity and water surface elevation along the cross section. This results shows grass concrete system is also suited to use in aggressive river environments such as repairing a flood damaged embankment that had placed at risk the adjacent drainage channel with vegetation.

  • PDF

Hydraulic Application of Grass Concrete In River Environment (하천환경에서의 그라스콘크리트의 적용성 연구)

  • Jang, Suk-Hwan;Nam, Yong-Hyuk;Kim, Seo-Young;Park, Seong-Beom;Park, Ung-Seo;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.472-477
    • /
    • 2006
  • This study aims at investigating the failure cases of the pre-cast block system in river environments which widely used nowadays and reviewing the effect and flow resistance for grass concrete structure through the physical experiments by hydraulic model test and developing application method in river slope or levee which has rigid flood resistance. Grass concrete structure has been independently tested under high velocity flow under the super critical condition, it survived the 8 m/sec maximum flow velocity. This results shows grass concrete system is also suited to use in aggressive river environments such as repairing a flood damaged embankment that had placed at risk the adjacent drainage channel with vegetation.

  • PDF

Growth of Grass and Control of temperature of Planting Concrete for Roof Using Recycled Aggregate (재생골재를 이용한 옥상식재용 콘크리트의 잔디생육과 열환경조정효과)

  • 이상태;김정진;황정하;김진선;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.237-242
    • /
    • 2001
  • The objective of this study is to investigate growth of grass planted with planting concrete using recycled aggregste. Planting concrete blocks are constructed on the roof of existing building. Temperature variation according to planting concrete method are also investigate. According to test results, it shows that grass grows very well under planting concrete method. When planting concrete method is applied, it brings about temperature reducing effects about 1~$2^{\circ}C$ at inner part of the buildings at cooling required period compared to that with existing roof, and at heating required period temperature insulating effects about 2~$4^{\circ}C$.

  • PDF

Development of Concrete Method for Roof Planting (건물옥상 식재용 콘크리트공법의 개발)

  • 이상태;김진선;황정하;한천구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.5
    • /
    • pp.48-57
    • /
    • 2000
  • This paper is dealing with the fundamental properties of planting concrete, replacing the existing cover concrete on the roof of a building. This study is to find out the physical characteristics of the planting concrete and rearing characteristics of the grass throughout the modeling experimental materials. As the results of the experiment, the physical properties of planting concrete show the following results; when the paste to aggregate ratio is 0.2~ 0.4, voids volume : 30~17%, unit weight: 1,710~2,010kg/m3, compressive strength : 45~145kgf/$\textrm{cm}^2$, its pH is more than 11, but is reduced to the proper degree for planting after being neutralized. Kentucky bluegrass covered with planting concrete is grown well. The planting concrete used with blast furnace slag cement shows a better properties at the height, the width and the covering rate by 1.1cm, 0.5mm and 7%, respectively, than those used with ordinary portland cement. Also, the less the paste to aggregate ratio is, the better the plant grows. The orders of the effects of temperature control are as follows; the system of planting concrete with grass>the system of planting concrete without grass>the system of mixed soil>the existed roof system. In case, the planting concrete is placed to the roofs of buildings instead of normal concrete slab, and a number of favorable effect can be expected such as the improvement os environmental factors, the reduction of construction cost, the saving of energy and the reduction of environment load. The future research on the change of a variety of the aggregate conditions and the application of the practical structures should be made, and also the research of the endurance also be performed.

  • PDF

A Quantitative Study on the Effect of Temperature Control by a Shade Tree and the Lawn Area (식물의 온도 완화효과에 관한 기초적 연구)

  • 안계복;김기선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study is to investigate the effect of temperature control by a shade tree and the lawn area. In this investigation, we find out that artificial-lawn, concerte, and exposed soil are more higher temperature than covered with plant materials. The results of the measurement may to summerized as follows; 1) Low-temperature effects of zoysia japonica is more controlled by condition of growth than leaf length of grass. Surface temperature make 0.7$^{\circ}C$ difference between long grass (15cm), and short grass (5cm), but make 5$^{\circ}C$ difference between good growth grass (230/10$\textrm{cm}^2$) and bad growth grass (80/10$\textrm{cm}^2$). 2) The surface temperature of the lawn area is 40.5$^{\circ}C$ lower on a maxinum than that of the artificial lawn (July 28, 1985). During the day of summer, shade area under the shade tree is 0.9$^{\circ}C$ lower then lawn area surface temperature, 6.9$^{\circ}C$ lower than bad growth lawn, 10.3$^{\circ}C$ lower than exposed soil, and 18$^{\circ}C$ lower than concrete surface temperature. 3) Natural irrigation effect on the surface temperature fluctuation. But this effect is changed by compositions of ground materials and time-lapse. 4) Sunny day is more effective than cloud day. 5) In summer season, surface temperature make a difference compare to temperature of 0.5-1.5m height from ground : Surface temperature is 3.4$^{\circ}C$ lower at the lawn area (11 a.m.), 4.2$^{\circ}C$ lower at the shade area the shade tree, 12.7$^{\circ}C$ higher at the concrete area (3p.m.), 38.8$^{\circ}C$ higher at the artificial lawn (2p.m.) 6) According to compositions of ground materials and season have specific vertical temperature distribution curve. 7) In summer season, temperature distribution of 0.5-1.5m hight at the shade tree is 4.8-5.7$^{\circ}C$ lower than concrete area (noon-3p.m.)

  • PDF

Study on Improvement of Thermal Environment by Green Roof Systems on RC Building - utilization of solar insulating block and the grass - (옥상녹화에 따른 콘크리트 건축물의 열환경 개선효과 -일사차폐블록과 잔디를 대상으로-)

  • Park, Chanpil;Furukawa, Nobuhisa
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Caused on the excessive heat accumulation of concrete material, the indoor thermal environment of reinforced concrete building is so bad in Okinawa. As the interruption of solar radiation could be one of the methods to improve it, the purpose of this study is to find out the effect of adopting solar radiation interrupting materials -Solar insulating block, Grass, and both of them- for the improvement of thermal environment. As the result, it was found that grass on the solar insulating block which has an air layer obviously improved the indoor thermal environment of RC building which was applied to. And it was found that the systems have an effectuality on heat island phenomenon simultaneously. It could be proposed as a good system which improve the indoor thermal environment of the existent houses.

Analysis for Behavior of Green Geosynthetic Reinforced Soil Walls by Laboratory Model Tests (실내모형실험에 의한 녹화보강토벽의 거동분석)

  • Cho, Yong-Sung;Kim, You-Seong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2003
  • The existing geotextile reinforced soil wall methods have a demerit in terms of esthetic view because concrete panel or block are used as wall facing of the methods. If grass planting walls could be used in reinforced soil slope or wall methods, efficiency of the methods would be increased with maximization of advantage of the methods. In this study, some possible methods in which grass planting wall is used as wall facing are devised. A series of laboratory model tests were performed to investigate the behavior of newly devised methods in order to compare with the results of each others. As a major result, it was found that this kinds of grass wall facing methods could be accepted as a new construction method even in the sense of stability.

  • PDF

The Effects of Components of Grazing System on Welfare of Fattening Pigs

  • Tozawa, Akitsu;Tanaka, Shigefumi;Sato, Shusuke
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.428-435
    • /
    • 2016
  • The objective of this study was to clarify the most effective component of grazing for improving welfare of fattening pigs. This study compared welfare indicators of 20 fattening pigs aged 100 to 124 days (the prior period) and 138 to 164 days (the latter period) in an indoor housing system (IS), an outdoor pasturing system (OP), a concrete floor paddock system (CF), a concrete floor paddock system with fresh grass (FG), or a soil floor paddock system (SF). The last three treatments include important components of a grazing system: extra space, grass feed, and soil floor. Behavior, wounds on the body, and performances, measured as average daily gain (ADG) and feed conversion ratio, were observed. CF pigs behaved similarly to IS pigs. FG pigs showed higher levels of foraging, chewing and activity. SF pigs engaged in higher levels of foraging, exploring, activity, and rooting, and showed a similar amount of playing behavior as OP pigs. ADG was the same in all treatments at the prior period, and increased in the order FG, IS, CF, SF, and OP at the latter. The behaviors and performance of SF pigs resembled those of OP which seemed to indicate a consistently higher standard of welfare than the other treatments. In conclusion, the existence of a soil floor is the most important component of a pasture for improving the welfare of pigs.

The Effect of Pervious Pavement on Reducing the Surface Runoff (투수성 포장재의 우수 표면유출 저감 효과)

  • Lee, Chun-Seok;Ryu, Nam-Hyung;Han, Seung-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.6
    • /
    • pp.26-37
    • /
    • 2008
  • The purpose of the study was to evaluate the effect of pervious pavements on reducing the surface runoff caused by rainfall. The surface runoff from twelve steel experimental beds with different pavement had been recorded every minute from May to September 2008, by the measuring system of tipping buckets(0.1mm/count) and data aquisition systems(National Instrument's Labview and DAQ boards & Autonics PR12-4). The dimension of the experimental bed was $1.5m(W){\times}2.0m(L){\times}0.6m(D)$ and eleven different kinds of vegetational(grass, grass+cubic stone, grass+hole brick), modular(brick, cubic stone, small cubic stone, wood block, interlocking block, clay brick, granular clay brick) and granular(naked soil, gravel) paving materials and concrete were applied for the comparison. Six rain events with depth over 30mm were selected and compared. The maximum depth of the rainfall selected was 137.5mm for 28 hours, and the minimum 30mm for 5 hours. The maximum rainfall per hour was 23mm/hr and the minimum 11.4mm/hr. The major findings were as follows; 1. All pervious pavement applied reduced over 75% of the surface runoff compared with concrete pavement. The grassy and porous pavements were relatively efficient in reducing surface runoff. 2. The grass was the more efficient as intercepting average 69.5mm of initial surface runoff, and maximum 77.8mm at the condition of 13.5mm/hr rainfall. The next was gravel intercepting maximum 65.5mm at the condition of 13.5mm/hr and the 40.9mm at 19.1mm/hr, average 55.7mm. 3. The modular pavements common in urban area were not good in intercepting the runoff except the 'clay granular brick' compared with others. The 'clay granular brick' showed relatively efficient intercepting average 14.1mm, which was the bigger amount than the 'grass+hole brick'. 4. The 'naked soil' were more effective than the 'concrete', 'brick', and 'interlocking block' in reducing the surface runoff, but less efficient than other materials. The capacity of the 'naked soil' to intercept the initial rainfall was similar to the 'brick'. As summary, the more grassy and porous pavement shows more effective in reducing surface runoffs.