• 제목/요약/키워드: granular filtration

검색결과 57건 처리시간 0.018초

여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가 (Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor)

  • 김태윤;이준배;이동우;신현석;김현철;권순철
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.

A Development Study on High Quality Drinking Water Production by the Biological Activated Carbon/immersed Membrane Filtration System

  • Inoue, Shiro;Iwai, Tosinori;Isse, Masaaki;Terui, Taturo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 국제 Workshop:상수원의 현황과 분리막 상수처리(Water Resource and Menbrane Water Treatment)
    • /
    • pp.155-162
    • /
    • 2001
  • Advanced drinking water production systems, which not only good quality product water, but also provide easy management and mainenance of facilities, and operate on a smaller site area, have been expected to be developed for some time. We are going ahead with a program to deveop an advanced drinking water production system, using immersed membrane filtration combined with biological activated carbon, to meet the need described above. The demonstration plant tests been conducted with surface water from the Yodo-river since Dec. 1998 to measure treatment performance, reliability, and controllability of the system. The quality of product water has consistently remained at a very high level for about 2 years under controlled conditions. Results showed that the re-circulation granular biological activated carbon could suppress the increase of membrane pressure difference and promote a reduction of dissolved organic matter. (This work has been conducted along the ACT21 Programs.)

  • PDF

정수처리과정(淨水處理過程)에서의 잔류불소(殘留弗素)이온 거동(擧動)에 관한 연구(硏究) (A Study on the Behavior of Residual Fluoride in Water Treatment Process)

  • 이택순;문병현;서규태;진홍식
    • 상하수도학회지
    • /
    • 제14권2호
    • /
    • pp.164-173
    • /
    • 2000
  • Fluoridation of drinking water to a level of about 0.8mg/l (below 1.5mg/l) for reducing the incidence of tooth decay is recommended. However, concerns about potential problems of unknown effects and overdosing hinders the fluoridation. This study describes the work performed to obtain information on the behavior of fluoride under various conditions in the process of water fluoridation. Effects of water treatment chemicals, water treatment unit, and water distribution on water fluoridation were investigated at both lab and an actual water treatment plant. Residual fluoride concentration was not affected by lime and chlorine dosage up to 20mg/l. Flocculation with PAC slightly decreased the residual fluoride concentration as PAC dosage increased. Average fluoride concentration of 0.87mg/l at an intake basin was decreased to 0.83mg/l by sedimentation, 0.81mg/l by dual media(sand+anthracite) filtration, and 0.79mg/l by granular activated carbon filtration in the water treatment plant.

  • PDF

여과초기에서의 탈착된 입자의 거동 (Role of Detached Particles During Initial Filtration Phase)

  • 김자겸
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성 (A study on the headloss of filter media for treatment of Road Runoff)

  • 최원석;송창수;김석구
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

정수처리를 위한 여과지의 역세척에 관한 연구 (A Study on Backwashing of Granular Fiters Used in Water Treatment)

  • 이정택;안종호;최근호
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

강우유출수에 의한 비점오염 저감을 위한 하향류식 입상여과 효율 평가 (Evaluation of Downflow Granular Media Filtration for Stormwater Treatment)

  • 임찬수;김도군;고석오
    • 대한환경공학회지
    • /
    • 제34권10호
    • /
    • pp.684-693
    • /
    • 2012
  • 도로와 차량의 증가에 의해 강우시 도로 유출수가 주변 수계의 오염을 크게 악화시키고 있다. 강우 유출수에 의한 비점오염 저감시설로 여과시설이 가장 널리 사용되고 있으나, 이들은 역세척이 불가능하므로 여재의 폐색과 오염물의 재유출 등을 고려하여야 한다. 본 연구에서는 강우유출수 SS 처리를 위한 하향류식 여과 특성을 검토하였다. 여재로 여과사, 왕사-활성탄, 발포 폴리프로필렌(EPP)을 검토한 결과, 간극이 큰 입상여재인 왕사-활성탄이 단위면적당 SS 처리량 $8.498kg/m^2$ 이상, 평균 SS 제거율 95% 이상이며, 손실수두가 적어 가장 우수한 특성을 나타냈다. EPP 역시 수두손실은 거의 없었으나, 간극의 크기와 간극률이 매우 크기 때문에 SS 제거율이 불안정하고 낮았다. 또한, 비점오염 여과시설에 가장 많이 사용되는 여과사는 $1.395kg/m^2$의 SS 처리량과 평균 95% 정도의 SS 제거율을 나타냈다. 여과사의 경우, 선속도는 SS 처리량에는 큰 영향이 없으나, 선속도가 낮을수록 운전시간이 증가하고 SS가 보다 깊은 여재층에서 제거되었다. 또한, 유입 SS 크기가 작을 때에는 여재의 수명이 크게 증가하고 심층여과 현상을 나타냈으나, 장기운전 시에는 포획된 SS 유출에 의해 SS 제거율이 감소하였다. SS 크기가 클 때에는 표면여과에 의해 SS가 제거되며 손실수두 증가가 빨라지는 것으로 나타났다. 비점오염 저감시설은 수리학적 부하의 변동이 크고 다양한 특성의 SS가 유입되므로, 하향류식 여과시설 설치 시, 선속도, SS 크기, 여재 특성과 현장 조건을 충분히 고려하여 설치하여야 할 것으로 판단된다.

여재구성에 따른 탁질입자 제거특성 및 효율 비교 (Pilot-Scale Evaluation of Granular Filters Using Particle Distribution Analysis)

  • 안종호;윤재흥
    • 대한환경공학회지
    • /
    • 제22권5호
    • /
    • pp.919-926
    • /
    • 2000
  • 정수장 여과지 모형실험장치를 이용하여 수중입자입도분석에 의한 모래 및 이중여재 여과지에 대한 여과특성 및 효율 평가를 탁도분석과 비교하여 실시하였다. 수중입자입도분석은 여과지의 효율 평가를 위한 훌륭한 평가방법으로 탁도분석에 비해 민감도가 뛰어나 여과유출수의 탁질누출 현상을 뚜렷이 관찰할 수 있었다. 모래여과지의 경우는 여과지속시간 내내 비교적 양호한 수질을 보여, 허용수두하에서는 초기탁질누출보다는 여과말기의 수위상승에 대한 주위가 필요하다. 반면에 이중여재 여과지의 경우는 내부여과에 의한 탁질의 침투가 이루어지므로 최적운영을 위해서는 적절한 여재구성과 각 여과지별로 연속적인 수질모니터링에 의한 탁질누출제어가 요구된다. 또한 보다 안정적이고 효율적인 수질의 확보를 위해서는 여과보조제의 사용도 고려되어야 할 것이다.

  • PDF

부직포 및 황 충진 MBR을 이용한 포기조내 동시 질산화/탈질에 관한 연구 (Simultaneous Nitrification and Denitrification using Submerged MBR packed with Granular Sulfur and Non-woven Fabric)

  • 문진영;황용우;박지형
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.439-446
    • /
    • 2009
  • This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.

이단이층 복합여과시스템의 소규모 파일롯 플랜트 적용성 평가 (Applicability Evaluation of Two-stages and Dual Media Filtration System by the Small-scale Pilot Plant)

  • 우달식;송시범;황병기
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.857-864
    • /
    • 2009
  • 본 연구에서는 겨울철 수온강하, 여름철 우천시 표류수 중의 고탁도 물질 및 봄, 가을철의 조류성장 시기 등을 고려하여 기존의 급속모래여과시스템을 이단 이층 복합여과시스템으로 개량하는 기술을 개발하는 것을 목표로 하였다. 본 기술은 기존 여과지의 개량 또는 신설 여과지 설계시 또 다른 부지의 확장 없이 기존 모래여과지를 대체하는 기술로서 하부집수장치 상부에 모래 + 활성탄 층을 두고 활성탄 층 상부에 일정한 간격의 역세 팽창층을 두고 전 처리의 개념으로 중간집수장치 위에 모래층을 두는 이단 이층 복합여과시스템을 말한다. 본 연구에서는 이단이층 복합여과시스템을 경기도 S 정수장에 소규모 파일롯 플랜트를 설치하였으며, 탁도는 INTU 이하로 안정하게 유지되었고, TOC, THMFP, HAAFP는 약 90%정도 제거되어 S정수장에 비해 약 2배 정도 높았으며, 이는 본 시스템의 하단에 충전된 활성탄층에서의 흡착 및 생물분해 효과에 기인된 것으로 판단된다.