• 제목/요약/키워드: grafting method

검색결과 377건 처리시간 0.026초

Physicochemical characterization of porcine bone-derived grafting material and comparison with bovine xenografts for dental applications

  • Lee, Jung Heon;Yi, Gyu Sung;Lee, Jin Woong;Kim, Deug Joong
    • Journal of Periodontal and Implant Science
    • /
    • 제47권6호
    • /
    • pp.388-401
    • /
    • 2017
  • Purpose: The physicochemical properties of a xenograft are very important because they strongly influence the bone regeneration capabilities of the graft material. Even though porcine xenografts have many advantages, only a few porcine xenografts are commercially available, and most of their physicochemical characteristics have yet to be reported. Thus, in this work we aimed to investigate the physicochemical characteristics of a porcine bone grafting material and compare them with those of 2 commercially available bovine xenografts to assess the potential of xenogenic porcine bone graft materials for dental applications. Methods: We used various characterization techniques, such as scanning electron microscopy, the Brunauer-Emmett-Teller adsorption method, atomic force microscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and others, to compare the physicochemical properties of xenografts of different origins. Results: The porcine bone grafting material had relatively high porosity (78.4%) and a large average specific surface area (SSA; $69.9m^2/g$), with high surface roughness (10-point average roughness, $4.47{\mu}m$) and sub-100-nm hydroxyapatite crystals on the surface. Moreover, this material presented a significant fraction of sub-100-nm pores, with negligible amounts of residual organic substances. Apart from some minor differences, the overall characteristics of the porcine bone grafting material were very similar to those of one of the bovine bone grafting material. However, many of these morphostructural properties were significantly different from the other bovine bone grafting material, which exhibited relatively smooth surface morphology with a porosity of 62.0% and an average SSA of $0.5m^2/g$. Conclusions: Considering that both bovine bone grafting materials have been successfully used in oral surgery applications in the last few decades, this work shows that the porcinederived grafting material possesses most of the key physiochemical characteristics required for its application as a highly efficient xenograft material for bone replacement.

거골의 골연골 병변에 대한 자가 골연골 이식술의 결과 (The Result of Autologous Osteochondral Grafting for the Osteochondral Lesion of the Talus)

  • 안영준;한성호;양보규;이승림;유재호;정선욱;빈성우;주민홍;김성완
    • 대한족부족관절학회지
    • /
    • 제10권1호
    • /
    • pp.48-55
    • /
    • 2006
  • Purpose: The purpose of this study is to assess the results of the autologous osteochondral grafting for the osteochondral lesion of the talus. Materials and Methods: This study included 21 patient who had been treated with the open autologous osteochondral grafting between December, 1999 and December 2003. We treated the patients with autologous osteochondral grafting method who had the lesion of stage II or medial lesion of stage III without improvement for at least 6 months, the medial lesion of stage IV, the lateral lesion of stage III, IV by Berndt and Harty's classification or who had not improved with previous operation. The average duration of follow up was 26 (12-56) months. 6 patients had been treated with the previous operation that 3 patients with drilling, 3 patients excision, curettage and drilling. Results: The average AOFAS Ankle/Hindfoot score was 92.7 points and no patient had a limitation of the daily activities due to pain or abnormal function. Postoperative radiography showed good joint congruency and postoperative MRI good incorporation of the graft. The average Lysholm knee score was 96 points and only two patients had mild knee pain during severe exertion. Conclusion: The autologous osteochondral grafting is the useful operative method when the lesion is advanced stage or when previous operative treatment has failed.

  • PDF

방사선을 이용한 바나듐 레독스 흐름전지용 이온 투과선택성 분리막의 제조 및 특성 평가 (Preparation and Characterization of Ionic Permselective Membrane by Radiation Grafting for Vanadium Redox Flow Battery)

  • 손준용;송주명;신준화
    • 방사선산업학회지
    • /
    • 제7권1호
    • /
    • pp.61-67
    • /
    • 2013
  • In this study, we developed ionic permselective membrane as a core material of redox flow battery using radiation grafting method. Two ionic permselective membranes, ETFE-g-PSSA and ETFE-g-PVBSA were prepared by radiation grafting with styrene and VBC followed by sulfonation, respectively. We confirmed that the prepared membranes were successfully prepared via FT-IR. The prepared ionic permselcetive membranes were characterized and the performance of the membranes were evaluated as ionic permselective membranes for vanadium redox flow battery.

Grafting 방법을 이용한 직접메탄올연료전지 애노드 촉매의 성능향상에 관한 연구 (An investigation on anode electrocatalysts using grafting method for improvement of DMFC performances)

  • 박정배;한국일;김하석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.413-416
    • /
    • 2006
  • PtRu catalyst is most widely used as anode catalyst for a direct methanol fuel cell(DMFC). To promote the efficiency of the catalysts, it Is important to increase the triple phase boundary. In this study, we have tried to increase the triple phase boundaries in preparing electrocatalysts of the fuel cells, based on the process of grafting a proton-conducting agent onto the catalyst This grafted proton-conducting agent can act as an ionomer like Nafion, currently widely used ionomer. First, we have prepared the 80wt% PtRu/Ketjen Black electrocatalyst by an improved colloidal method. And, we have grafted methylsulfonate groups $(-CH_2SO_3H)$ into the catalyst as proton-conducting agents. As results of cyclic voltammety and single cell test of the membrane electrode assembly (MEA), we can conclude that the activity of the grafted electrocatalysts is superior to that of conventional ones, in performance of DMFCs. For our further study, we will investigate the optimum ratio of catalyst/grafted proton conduct Ing agent with maximum performance of a DMFC.

  • PDF

불소수지 필름에 2-Hydroxyethyl methacrylate와 스틸렌의 방사선 그라프트 공중합 (Radiation-Induced Graft Copolymerization of 2-hydroxyethyl-methacrylate and Styrene onto Polytetrafluoroethylene)

  • 노영창;;;진준하
    • 공업화학
    • /
    • 제3권3호
    • /
    • pp.491-498
    • /
    • 1992
  • 2-hydroxyethyl methacrylate(HEMA)나 스틸렌을 단독 혹은 혼합하여 ${\gamma}-ray$를 사용한 동시조사법으로 불소수지 필름에 공중합시켰다. 단량체 농도, 조사속도, 조사량, 용매형태 및 HEMA와 스틸렌의 혼합조성비가 방사선 그라프트율에 미치는 영향을 검토하였다. HEMA 단독으로 불소수지 필름에 그라프트시킨 경우의 그라프트율은 자주 적었으나 HEMA와 styrene 혼합물의 그라프트 공중합은 좋은 수율을 나타내었다. 그라프트 용액에 황산을 첨가하면 그라프트율 상승효과가 나타났다.

  • PDF

Physical stability of arginine-glycine-aspartic acid peptide coated on anodized implants after installation

  • Huh, Jung-Bo;Lee, Jeong-Yeol;Jeon, Young-Chan;Shin, Sang-Wan;Ahn, Jin-Soo;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.84-91
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation. MATERIALS AND METHODS. Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical grafting method (C). Solid Rigid Polyurethane Foam (SRPF) was classified as either hard bone (H) or soft bone (S) according to its density. Two pieces of artificial bone were fixed in a customized jig, and coated implants were installed at the center of the boundary between two pieces of artificial bone. The test groups were classified as: P-H, P-S, C-H, or C-S. After each installation, implants were removed from the SRPF, and the residual amounts and rates of RGD peptide in implants were measured by fluorescence spectrometry. The Kruskal-Wallis test was used for the statistical analysis (${\alpha}$=0.05). RESULTS. Peptide-coating was identified by fluorescence microscopy and XPS. Total coating amount was higher for physical adsorption than chemical grafting. The residual rate of peptide was significantly larger in the P-S group than in the other three groups (P<.05). CONCLUSION. The result of this study suggests that coating doses depend on coating method. Residual amounts of RGD peptide were greater for the physical adsorption method than the chemical grafting method.

방사선 동시조사법에 의해 제조된 FEP-g-PSSA 막의 그래프트 분포에 관한 연구 (A Study on the Graft Distribution of the FEP-g-PSSA Membranes Prepared by a Simultaneous Irradiation Method)

  • 고범석;신준화;손준용;노영창;장필현
    • 폴리머
    • /
    • 제33권3호
    • /
    • pp.268-271
    • /
    • 2009
  • 본 연구에서는 방사선 동시조사법에 의해 제조된 FEP-g-PSSA 막 단면을 SEM-EDX 기기로 분석하여 스티렌 술폰산 고분자(PSSA)의 막 내부로의 분포 경향을 연구하였다. 본 실험에서는 그래프트율, FEP 필름 두께, 선량률, 그래프팅 용매 등 여러 조사조건이 그래프트 고분자의 분포에 미치는 영향을 중점적으로 연구하였다. 실험 결과 균일하게 그래프트된 FEP-g-PSSA 막을 얻기 위해서는 필름 두께가 증가할수록 높은 그래프트율이 요구되어지고, 같은 조사 선량에서는 낮은 조사 선량률로 그래프트하는 것이 효과적임을 보여준다.

Polycyclotriphosphazene Derivative Grafted and NanometerY2O3 Doped SPEEK Composite Membrane for DMFC

  • Li, Xia;Guo, Qiang;Zhang, Tianjiao;Qian, Junzhi;Tan, Xiaolin
    • 대한화학회지
    • /
    • 제57권5호
    • /
    • pp.625-633
    • /
    • 2013
  • A type of polycyclotriphosphazene derivative (PCTPD), hexasulfanilic acid polycyclotriphosphazene (HSACP) and HSACP grafting SPEEK, sulfonated poly[2-(petachloropolycyclotriphosphazene-oxy)] etheretherketone (SPPSACPEEK) were synthesized, which were characterized by FTIR and $^{31}P$ NMR. Then three types of composite membranes such as HSACP grafting SPEEK, HSACP blending SPEEK, and nano $Y_2O_3$ doping and HSACP grafting SPEEK, respectively, were continuously prepared by solution-casting method. Comparing to SPEEK membranes with different amount of HSACP grafted or blended, grafting 15 wt% HSACP and doping 10 wt% nano $Y_2O_3$ SPEEK membrane conducted outstanding overall behavior of proton conductivity reaching $3.18 {\times}10^{-2}$ S/cm at $90^{\circ}C$ which was merely junior to SPEEK with 15 wt% HSACP grafted, methanol permeability coefficient getting $9.46{\times}10^{-8}cm^2{\cdot}s^{-1}$, swelling degree of 20.9% and solid residue of 98.98% which was superior to all specimen.

폴리프로필렌에 UV 흡수제를 갖는 말레이미드의 용융그래프팅 (Thermal Melt Grafting of Maleimides Having UV-absorber onto Polypropylene)

  • 김택현;나혜선
    • 폴리머
    • /
    • 제38권1호
    • /
    • pp.49-53
    • /
    • 2014
  • 새로운 단량체형의 자외선흡수제를 triethylamine에서 2,4-dihydroxybenzophenone과 N-4-chlorocarbonyl-phenylmaleimide의 반응을 통하여 합성하였다. 이 자외선흡수제를 폴리프로필렌에 용융반응에 의해 그래프팅하였다. Maleimide의 그래프팅 수율은 IR 분광 데이터를 이용하여 결정하였다. 용융반응의 최적조건을 구하기 위하여 반응온도 및 시간, 단량체의 농도의 변화에 대하여 그래프팅 수율을 구하였다. Weatherometer에서 IR 스펙트럼의 카보닐 지수를 이용하여 그래프트된 폴리프로필렌의 광산화 정도를 조사하였으며, 우수한 광산화 억제작용을 보였다.

Polymer brush: a promising grafting approach to scaffolds for tissue engineering

  • Kim, Woonjung;Jung, Jongjin
    • BMB Reports
    • /
    • 제49권12호
    • /
    • pp.655-661
    • /
    • 2016
  • Polymer brush is a soft material unit tethered covalently on the surface of scaffolds. It can induce functional and structural modification of a substrate's properties. Such surface coating approach has attracted special attentions in the fields of stem cell biology, tissue engineering, and regenerative medicine due to facile fabrication, usability of various polymers, extracellular matrix (ECM)-like structural features, and in vivo stability. Here, we summarized polymer brush-based grafting approaches comparing self-assembled monolayer (SAM)-based coating method, in addition to physico-chemical characterization techniques for surfaces such as wettability, stiffness/elasticity, roughness, and chemical composition that can affect cell adhesion, differentiation, and proliferation. We also reviewed recent advancements in cell biological applications of polymer brushes by focusing on stem cell differentiation and 3D supports/implants for tissue formation. Understanding cell behaviors on polymer brushes in the scale of nanometer length can contribute to systematic understandings of cellular responses at the interface of polymers and scaffolds and their simultaneous effects on cell behaviors for promising platform designs.