• Title/Summary/Keyword: graft ratio

Search Result 221, Processing Time 0.023 seconds

The Study on the Gragting Rate MAA onto Silk Fiber by Redox System (Redox계에 의한 MAA Gragt 속도에 관한 연구)

  • 배도규;김종호
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.1
    • /
    • pp.62-66
    • /
    • 1997
  • The MAA graftings in silk fiber were done by redox system for the purpose of investingating the effect of ferrous sulfate additive on the grafting rate and graft ratio in various conditions. The graft ratio was higher in redox graft system than in peroxide graft system and the graft ratio in redox graft system was also higher depending on decrease of ferrous sulfate additive. The saturation graft ratio obtained by empirical equation, log X=K/t, was increasing depending on the increase of ferrous sulfate additive. Initial grafting rate was increased but the latter grafting rate was decreased in redox graft system. The effects of liquor ratio(L.R.) on the graft ratio in redox graft system, were higher in high L.R. than in low L.R..

  • PDF

The Effect of Graft using Acrylic Acid on the Detergency for the Nylon 6 Fabric -Improvement of Hemoglobin Removing Rate on Grafted Nylon- (나일론 6 직물의 아크릴산 그라프트 중합과 그라프트 나일론의 세척성 -그라프트 나일론 직물의 헤모글라빈 오구 세척성 향상-)

  • 오수민;김인영;송화순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.1064-1072
    • /
    • 1999
  • Nylon fabric was grafted for the purpose of the development of detergency against the hemoglobin as a protein soil. By free-radical producing chemical initiator systems the graft using acrylic acid(AA) as a hydrophilic vinyl monomer was performed to change surface energies in the presence of ammonium persulfate(APS) as an initiator and then acrylic acid grafted Nylon was treated with NaOH solution. The surface morphology for Nylon-g-NaAA with changing graft rate were studied by scanning electron microscopy (SEM) The properties of the Nylon such as diameter tenacity elongation contact angle and the hemoglobin removal were also investigated. The diameter of grafted Nylon fiber increased as the graft ratio increased. The tenacity of grafted Nylon also increased with increasing graft ratio up to 15% The elongation however decreased gradually according to graft, The contact angle decreased after graft and alkaline treatment. The amount of hemoglobin on the grafted Nylon increased in proportion to the graft ratio. Hemoglobin was easily removed from grafted Nylon while it was difficult to be removed from ungrafted Nylon. The detergency of hemoglobin for grafted Nylon decreased when the graft ratio exceeded 15% The removal of hemoglobin increased markedly with increasing hemoglobin content and revolution speed. Therefore the removal of hemoglobin was improved due to graft and alkaline treatment.

  • PDF

Ultraviolet Photografting Reaction of Acrylamide onto Styrene-Butadiene Rubber (Styrene-Butadiene 고무의 아크릴아미드 UV 광그라프팅 반응)

  • Lee, K.I.;Ryu, S.H.
    • Elastomers and Composites
    • /
    • v.33 no.5
    • /
    • pp.363-369
    • /
    • 1998
  • Photografting reaction onto styrene-butadiene rubber (SBR) as a function of monomer concentration, irradiation time and carbon black content has been studied using ultraviolet (UV). Acrylamide and benzophenone are used as monomer and photoinitiator, respectively. FT-IR ATR and static contact angle analysis using distilled water are used to measure the graft ratio of acrylamide onto SBR surface. Graft ratio of acrylamide increases with acrylamide concentration and irradiation time and contact angle tends to decrease with increasing graft ratio. It is observed that graft ratio increases with carbon black content.

  • PDF

TECHNETIUM-99m BONE SCAN FOR EVALUATING AUTOLOGOUS ILIAC BONE GRAFT AND FREEZE-DRIED BONE ALLOGRAFT IN DOG'S MANDIBLE (Technetium-99m 골주사를 이용한 하악골의 자가골 및 동종골 이식의 평가에 대한 실험적 연구)

  • Jin, Sung-Bark;Kim, Soo-Kyung
    • The Journal of the Korean dental association
    • /
    • v.22 no.1 s.176
    • /
    • pp.37-48
    • /
    • 1984
  • Clinical assessment of bone-graft healing in the maxillofacial region is generally limited to clinical evaluation, radiographs, and biopsy. Sequential interpretation of osseous repair, more sensitive than with conventional radiography is possible with a non-invasive, non-destructive radionuclide method. Technetium-99m radionuclide bone scan was used in the evaluation of the progress of osteogenic activity in autologous iliac bone graft and freeze-dried bone allograft of dog's mandible. Bone scan was performed at 1wk, 2wk, 4wk, 6wk, and 8wk after grafting. In autologous graft the activity ratio for the graft bone remained greater than that of the host since 2자 after grafting; however, in lyophilized allograft the activity ratio for graft bone was greater than that of the host at 6자 after grafting.

  • PDF

Removal of Hemoglobin from Acrylic Acid Grafted Nylon Fabric The Removal and the State of Adhesion of Hemoglobin on Grafted Nylon Fabric- (아크릴산 그라프트 중합한 나일론 직물의 헤모글로빈 오구 세척성 -그라프트 나일론 직물에 대한 헤모글로빈 부착상태와 세척성-)

  • 오수민;김인영;송화순
    • Textile Coloration and Finishing
    • /
    • v.11 no.3
    • /
    • pp.41-48
    • /
    • 1999
  • The removal of hemoglobin from acrylic acid grafted Nylon fabrics has been investigated. In order to change detergency of Nylon 6 fabric, acrylic acid(AA) were graft copolymerized on Nylon fabric using ammonium persulfate(APS) as a initiator, and then acrylic acid grafted Nylon was treated with NaOH solution. The graft ratio increased linearly with increasing acrylic acid concentration. The graft ratio was the highest when the concentration of APS was 0.05%, and it decreased as the concentration of APS increased. The surface of Nylon fabric became rough due to graft. Moisture regain was increased by graft and alkaline treatment, contact angle was also improved compared with the ungrafted. The hemoglobin was easily solubilized and removed from grafted Nylon fabric, while it was difficult to remove hemoglobin from ungrafted Nylon fabric. The effects of graft on removal of hemoglobin was related with increase of moisture regain and transformation of COOH to COONa by alkaline treatment.

  • PDF

Preparation of Alginate/Poly(N-isopropylacrylamide) Hydrogels Using Gamma-ray Irradiation Grafting

  • Lee, Young-Moo;Lee, Sang-Bong;Seo, Sung-Mi;Lim, Youn-Mook;Cho, Seong-Kwan;Nho, Young-Chang
    • Macromolecular Research
    • /
    • v.12 no.3
    • /
    • pp.269-275
    • /
    • 2004
  • To graft N-isopropylacrylamide (NIPAAm) onto alginate, varying dosages of ${\gamma}$-rays were irradiated onto alginate films in deionized water and methanol media, which are non-solvents of alginate. We investigated the hydrogels graft ratio, mechanical strength, swelling kinetics and ratio, and behavior with respect to drug release. The graft yield of NIPAAm increased upon increasing the irradiation dose. The use of the aqueous solution increased the graft yield relative to that obtained in methanol. The mechanical strength of the grafted hydrogels increased after grafting with NIPAAm. In a study of the swelling kinetics, we found that all hydrogels reached an equilibrium swollen state within 3 h. The equilibrium swelling ratio of the hydrogels decreased upon increasing the irradiation dose. The swelling ratio of the hydrogels decreased dramatically between 30 and 35$^{\circ}C$ because phase separation of NIPAAm occurred at 32$^{\circ}C$. The swelling process, with respect to the temperature change, was repeatable. An NIPAAm-grafted alginate containing a drug sustained its release rate until 3 h after an initial high drug release caused by a burst effect.

Graft Copolymerization of Acrylic Monomer Containing Aromatic Carboxylic Acid Group onto EPDM and Their Mechanical Properties (EPDM에 방향족 카르복시산을 함유하는 아크릴 단량체의 그라프트 공중합과 기계적 특성)

  • Park, Hyun-Ju;Park, Jong-Hyuk;Bae, Jong-Woo;Kim, Gu-Ni;Oh, Sang-Taek
    • Elastomers and Composites
    • /
    • v.47 no.3
    • /
    • pp.216-222
    • /
    • 2012
  • In this study, p-acryloyloxybenzoic acid(ABA) was synthesized with p-hydroxybenzoic acid(HBA) and acryloyl chloride(AC). The synthesized ABA monomer was grafted onto ethylene-propylene-diene rubber(EPDM) in toluene using benzoyl peroxide(BPO) as an initiator. The structures of ABA and EPDM-g-ABA were characterized by FT-IR, $^1H$-NMR, and $^{13}C$-NMR spectrometer. The graft ratio of EPDM-g-ABA increased with increasing the concentration of the initiator and the monomer. Mechanical properties such as tensile strength and compression set of the EPDM-g-ABA were improved with increasing the graft ratio. The $T_g$ and initial decomposition temperature were also increased with increasing the graft ratio.

A Study on the Physical Properties and Handle of Polyester Fabrics Grafted with Methacrylic Acid (MA 그라프트 폴리에스테르직물의 물성 및 태변화에 관한 연구)

  • Baik, Chun-Eui;Cho, Seung-Sik;Song, Wha-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • The purpose of this study is the investigation of the physical properties, handle variation of polyester fabrics grafted methacrylic acid. The results are as follow 1. In the case of moisture recovery, MA-g-PET results in an improvement of approximately 4% when the graft ratio reaches 25%, whilst Na-MA-g-PET results in an improvement of approximately 9% when the graft ratio reaches 20%. 2. The static electricity of Na-MA-g-PET, is rarely generated when the graft ratio exceeds 10% . 3. The T.H.V. indicate that the values had deteriorated in the case of MA-g-PET, whilst the N a-Ma-a.PET values demonstrated superiority. 4. The value resulting from the MA-g-PET and Na-MA-g-PET treatment methods are calculated as being 0.0130, whilst the value pursuant to graft ratio is 0.0000.

  • PDF

Amphiphilic graft copolymers: Effect of graft chain length and content on colloid gel

  • Nitta, Kyohei;Kimoto, Atsushi;Watanabe, Junji;Ikeda, Yoshiyuki
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.97-109
    • /
    • 2015
  • A series of amphiphilic graft copolymers were synthesized by varying the number of graft chains and graft chain lengths. The polarity of the hydrophobic graft chain on the copolymers was varied their solution properties. The glass transition temperature of the copolymers was in the low-temperature region, because of the amorphous nature of poly (trimethylene carbonate) (PTMC). The surface morphology of the lyophilized colloid gel had a bundle structure, which was derived from the combination of poly(N-hydroxyethylacrylamide)( poly(HEAA)) and PTMC. The solution properties were evaluated using dynamic light scattering and fluorescence measurements. The particle size of the graft copolymers was about 30-300 nm. The graft copolymers with a higher number of repeating units attributed to the TMC (trimethylene carbonate) component and with a lower macromonomer ratio showed high thermal stability. The critical association concentration was estimated to be between $2.2{\times}10^{-3}$ and $8.9{\times}10^{-2}mg/mL$, using the pyrene-based fluorescence probe technique. These results showed that the hydrophobic chain of the graft copolymer having a long PTMC segment had a low polarity, dependent on the number of repeating units of TMC and the macromonomer composition ratio. These results demonstrated that a higher number of repeating units of TMC, with a lower macromonomer composition, was preferable for molecular encapsulation.

Changes in Acid Graft Ratio and Al-CPP Lamination Peel Strength by Polyolefin Reaction Conditions (폴리올레핀의 반응 조건별 산변성도 변화 및 Al-CPP 라미네이션 박리강도 변화)

  • Jong Hyun Park;Hong Jun Chae
    • Journal of Adhesion and Interface
    • /
    • v.25 no.1
    • /
    • pp.152-156
    • /
    • 2024
  • We conducted research on a two-component epoxy adhesive material based on acid graft polyolefin using maleic anhydride to address the lack of formability due to epoxy adhesives' hard segments. To understand the graft efficiency according to reaction conditions, we conducted studies based on polyolefin molecular weight, initiator half-life, and initiator concentration for each process. The maleic anhydride grafted polyolefin produced was used as an adhesive material for aluminum and CPP film lamination after mixing with epoxy hardener. The graft efficiency in the solution process was approximately 30% superior to that in the melt process, and an increase in graft ratio confirmed an increase in peel strength.