• Title/Summary/Keyword: gradient stack

Search Result 21, Processing Time 0.021 seconds

Optimization of Operational and Constitutional Geometric Parameters for Thermoaoustic Energy Output

  • Oh, Seung Jin;Shin, Sang Woong;Chen, Kuan;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.28-38
    • /
    • 2014
  • The effects of geometric parameters (stack position, stack length, resonator tube length) and varying input power over acoustic energy output were investigated. The acoustic laser kit (Garret 2000) was used for the construction of TA lasers. A series of sound pressure level measurements in different orientations did not differ significantly confirming that the sound wave generated could be assumed as a spherical wave. An increase in acoustic pressure was recorded with respective increase in input power, stack and resonator tube lengths owing to their relative influence over heat transfer rate and critical temperature gradient across the stack.

Operation of A Small MCFC Stack Using New Designed Circular Separator (새로운 원반형 구조의 분리판을 사용한 소형 용융탄산염 스택의 운전)

  • Han, Jonghee;Roh, Gil-Tae;Yoon, Sung Pill;Nam, Suk Woo;LIm, Tae Hoon;Hong, Seong Ahn
    • Journal of Hydrogen and New Energy
    • /
    • v.14 no.3
    • /
    • pp.229-235
    • /
    • 2003
  • A 50W class MCFC stack was operated in order to test a new design of the circular shaped separator. in the new design, the anode gas was supplied into the stack and was exhausted out of the stack after the anode reaction. The exhausted gas was reacted with the cathode gas supplied with excess oxygen in the vessel in which the stack was placed. Then the reacted gas flowed into the cathode side of the stack and was exhausted through the outlet located in the center of the stack. The average voltage of the single cells in the stack was 0.835V under the current density of $150mA/cm^2$, initially, and the degradation rate of the stack voltage was 1.7%/1,000h. High stack voltage with good stability of the present stack was due to the small temperature gradient in the stack. The small temperature gradient as well as the easiness of temperature control was the result of the new configuration of the separator which utilized the heat of the combustion reaction between anode outlet gas and the cathode inlet gas for heating the stack.

Iterative Least-Squares Method for Velocity Stack Inversion - Part B: CGG Method (속도중합역산을 위한 반복적 최소자승법 - Part B: CGG 방법)

  • Ji Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.170-176
    • /
    • 2005
  • Recently the velocity stack inversion is having many attentions as an useful way to perform various seismic data processing. In order to be used in various seismic data processing, the inversion method used should have properties such as robustness to noise and parsimony of the velocity stack result. The IRLS (Iteratively Reweighted Least-Squares) method that minimizes ${L_1}-norm$ is the one used mostly. This paper introduce another method, CGG (Conjugate Guided Gradient) method, which can be used to achieve the same goal as the IRLS method does. The CGG method is a modified CG (Conjugate Gradient) method that minimizes ${L_1}-norm$. This paper explains the CGG method and compares the result of it with the one of IRSL methods. Testing on synthetic and real data demonstrates that CGG method can be used as an inversion method f3r minimizing various residual/model norms like IRLS methods.

Operation Characteristics and Analysis of Temperature Gradients in a 5-kW Molten Carbonate Fuel Cell Stack (5 kW 용융탄산염 연료전지 스택내 운전특성 및 온도 변화 해석)

  • Lim, Hee-Chun;Koh, Joon-Ho;Ryu, Jeong In
    • Journal of Hydrogen and New Energy
    • /
    • v.10 no.2
    • /
    • pp.107-118
    • /
    • 1999
  • A 5-kW MCFC stack with $3,000cm^2$ electrode area was tested to investigate cell performance and operation characteristics. The stack performance was evaluated based on electrical output and I-V change. The stack showed high cell performance (7.6 kW) than the design performance and operated for more than 5,760 hours, but a significant temperature gradient inside the stack was observed. A 3-dimensional mathematical model for molten carbonate fuel cell (MCFC) was developed for the purpose of simulation of stack performance during the operation. The model was solved using PHOENICS, a computational fluid dynamics (CFD) code. The simulation result demonstrated a close prediction of the temperature gradient and stack performance.

  • PDF

Evaluation of Reverse Electrodialysis based on the Number of Cell Pairs and Stack Size Using Patterned Ion Exchange Membrane (패턴형 이온교환막을 이용한 스택의 셀 수 및 크기에 따른 역전기투석 성능 평가)

  • Dong-Gun Lee;Hanki Kim;Namjo Jeong;Young Sun Mok;Jiyeon Choi
    • New & Renewable Energy
    • /
    • v.19 no.2
    • /
    • pp.31-39
    • /
    • 2023
  • Salinity gradient energy can be generated from a mixture of water streams with different salt concentrations by using reverse electrodialysis (RED). In this study, we evaluated the effect of stack size and number of cell pairs on the energy efficiency and specific energy of the RED process. Additionally, we studied the prementioned parameters to maximize the power density of RED. The performance of the RED stack which used a patterned ion exchange membrane, was evaluated as a function of stack size and feed flow rate. Moreover, it was noted that an increase in stack size increased the ion movement through the ion exchange membrane. Furthermore, an increase in feed flow rate led to a reduction in the concentration variation, resulting in an increase in OCV and power density. The energy efficiency and specific energy for 100 cells in the 10 × 10 cm2 stack were the highest at 12% and 0.05 kWh/m3, respectively, while the power density from 0.33 cm/s to 5 × 5 cm2 stack was the highest at 0.53 W/m2. The study showed that the RED performance can be improved by altering the size of the stack and the number of cell pairs, thereby positively affecting energy efficiency and specific energy.

Analysis and Experiment of Heat Conduction and Heat Pumping in a Thermo-Acoustic Refrigerator Stack (열음향 냉동기 스택에서의 열전도와 열펌핑의 해석 및 실험)

  • Ku, B.K.;Song, T.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.473-487
    • /
    • 1995
  • A loud speaker-driven zero-c.o.p. thermoacoustic refrigerator where an automotive catalytic converter is utilized as a stack has been fabricated and investigated experimentally. Without any heat exchangers at both ends of stack(and thus with zero c. o. p.), temperatures on the stack are measured and various heat transfer rates are calculated from the measured temperatures. Temperatures on the stack have been also calculated numerically using a finite difference method. The measured temperatures are in fair agreement with the calculated temperatures for lower frequency than 300Hz, however, the former deviates from the latter considerably for higher frequency. Two types of c. o. p. have been defined as appropriate to the experiment. While the nominal c. o. p. is zero(the condition in which the pumped heat flow rate in the pore exactly cancels the axial heat conduction down the stack), the true c. o. p. is found to be about 0.14 for 300Hz from the experiments.

  • PDF

A Comparative Study on the Characteristics of Thermoacoustic Waves by the Stack Channel Number (스택의 채널 수에 다른 열음향파의 특성 비교 연구)

  • Park, Sung-Seek;Cheon, Won-Gi;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.8-14
    • /
    • 2013
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level(SPL), onset time and the temperature gradient across the stack, with the Cell Per Square Inch(CPSI) of stack changed. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. As a result, when the supply electric power was 25W, maximum SPLs of 104.1 dB, 109.4 dB and 112.8 dB were detected for the stacks of 200, 300 and 400 CPSI and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

A Comparative Study on the Characteristics of Thermoacoustic Laser for Applying Solar Energy (태양열 적용을 위한 열음향 레이저의 특성 비교 연구)

  • Park, Sung-Seek;An, Eoung-Jin;Oh, Seung-Jin;Chun, Won-Gee;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.105-112
    • /
    • 2012
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level (SPL), frequency, onset time and the temperature gradient across the stack. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. For a resonance tube of 100 mm, no acoustic waves were generated with a power input of 25W. By increasing its length to 200 mm, however, maximum SPLs of 96.4 dB, 106.3 dB and 112.8 dB were detected for the tubes of 10mm,20mm and 30mm in IDs and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

A Comparative Study on the Characteristics of Thermoacoustic Laser for Using Solar Energy (태양에너지 이용을 위한 열음향 레이저의 특성 비교 연구)

  • Park, Sung-Seek;An, Eoung-Jin;Oh, Seung-Jin;Chun, Won-Gee;Kim, Nam-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.516-521
    • /
    • 2012
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level (SPL), frequency, onset time and the temperature gradient across the stack. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. For a resonance tube of 100mm, no acoustic waves were generated with a power input of 25W. By increasing its length to 200mm, however, maximum SPLs of 96.4 dB, 106.3 dB and 112.8 dB were detected for the tubes of 10mm, 20mm and 30mm in IDs and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

  • PDF

A Study for Characteristics of Stack Plume Dispersion under Various (다양한 대기풍속 및 대기온도 구배 조건에서의 공장 배출 가스의 확산 특성에 관한 연구)

  • Park, Il-Seouk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.773-780
    • /
    • 2010
  • The dispersion of plume which is emitted from a chimney is governed by a lot of factors: wind, local terrain, turbulence intensity of atmosphere, and temperature, etc. In this study, we numerically investigate the plume dispersions for various altitudinal temperature gradients and wind speeds. The normal atmosphere has the temperature decrease of $0.6^{\circ}C/100m$, however, actually the real atmosphere has the various altitudinal temperature profiles according to the meteorological factors. A previous study focused on this atmospheric temperature gradient which induces a large scale vertical flow motion in the atmosphere thus makes a peculiar plume dispersion characteristics. In this paper, the effects of the atmospheric temperature gradient as well as the wind speed are investigated concurrently. The results for the developing processes in the atmosphere and the affluent's concentrations at the ambient and ground level are compared under the various altitudinal temperature gradients and wind speeds.