• Title/Summary/Keyword: gradient flow

Search Result 1,171, Processing Time 0.024 seconds

A NEW PRESSURE GRADIENT RECONSTRUCTION METHOD FOR A SEMI-IMPLICIT TWO-PHASE FLOW SCHEME ON UNSTRUCTURED MESHES (비정렬 격자 기반의 물-기체 2상 유동해석기법에서의 압력기울기 재구성 방법)

  • Lee, H.D.;Jeong, J.J.;Cho, H.K.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.15 no.2
    • /
    • pp.86-94
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been developed for the analysis of transient two-phase flows in nuclear reactor components. A two-fluid three-field model was used for steam-water two-phase flows. To obtain numerical solutions, the finite volume method was applied over unstructured cell-centered meshes. In steam-water two-phase flows, a phase change, i.e., evaporation or condensation, results in a great change in the flow field because of substantial density difference between liquid and vapor phases. Thus, two-phase flows are very sensitive to the local pressure distribution that determines the phase change. This in turn puts emphasis on the accurate evaluation of local pressure gradient. This paper presents a new reconstruction method to evaluate the pressure gradient at cell centers on unstructured meshes. The results of the new scheme for a simple test function, a gravity-driven cavity, and a wall boiling two-phase flow are compared with those of the previous schemes in the CUPID code.

Flow Analysis of Mounting Gradient of Protective Glass Around Motorcycle (이륜차 보호유리의 장착 기울기에 따른 이륜차 주위에서의 유동 해석)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.596-601
    • /
    • 2014
  • In this study, driving efficiency and the safety of motorcycle drivers due to the mounting gradient of motorcycle protective glass are investigated through flow analysis. Mounting gradients of motorcycle protective glass in models 1, 2, and 3 are $60^{\circ}$, $70^{\circ}$, and $80^{\circ}$, respectively. Wind velocity of 100 km/h is applied to the protective glass installed at the front of each model. The flow resistance values of models 2 and 3 are 1.2 and 1.5 times, respectively, that of model 1. The driving efficiency of model 1 is the highest among the three models. Pressure to the driver's face in models 2 and 3 is 1.2 times higher than in model 1. Because the pressure to the driver's face in model 1, with mounting gradient of $60^{\circ}$, is the lowest among the three models, model 1 is the safest. This result can be applied to improve the safety of motorcycle drivers.

FINITE SPEED OF PROPAGATION IN DEGENERATE EINSTEIN BROWNIAN MOTION MODEL

  • HEVAGE, ISANKA GARLI;IBRAGIMOV, AKIF
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.26 no.2
    • /
    • pp.108-120
    • /
    • 2022
  • We considered qualitative behaviour of the generalization of Einstein's model of Brownian motion when the key parameter of the time interval of free jump degenerates. Fluids will be characterised by number of particles per unit volume (density of fluid) at point of observation. Degeneration of the phenomenon manifests in two scenarios: a) flow of the fluid, which is highly dispersing like a non-dense gas and b) flow of fluid far away from the source of flow, when the velocity of the flow is incomparably smaller than the gradient of the density. First, we will show that both types of flows can be modeled using the Einstein paradigm. We will investigate the question: What features will particle flow exhibit if the time interval of the free jump is inverse proportional to the density and its gradient ? We will show that in this scenario, the flow exhibits localization property, namely: if at some moment of time t0 in the region, the gradient of the density or density itself is equal to zero, then for some T during time interval [t0, t0 + T] there is no flow in the region. This directly links to Barenblatt's finite speed of propagation property for the degenerate equation. The method of the proof is very different from Barenblatt's method and based on the application of Ladyzhenskaya - De Giorgi iterative scheme and Vespri - Tedeev technique. From PDE point of view it assumed that solution exists in appropriate Sobolev type of space.

An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-2) (지하수류가 밀폐형 천공 지중 열교환기 성능에 미치는 영향(2))

  • Hahn, Jeongsang;Kiem, Youngseek;Lee, Juhyun;Lee, Byoungho;Hahn, Chan
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.114-127
    • /
    • 2016
  • An increase of groundwater flux in BHE system creates that ground temperature (locT) becomes lower in summer and higher in winter time. In other words, it improves significantly the performance of BHE system. The size of thermal plume made up by advection driven-flow under the balanced energy load is relatively small in contrast to the unbalanced energy load where groundwater flow causes considerable change in the size of thermal plume as well ground temperature. The ground temperatures of the up gradient and down gradient BHEs under conduction only heat transport are same due to no groundwater flow. But a significant difference of the ground temperature is observed between the down gradient and up gradient BHE as a result of groundwater flow-driven thermal interference took placed in BHE field. As many BHEs are designed under the obscure assumption of negligible groundwater flow, failure to account for advection can cause inefficiencies in system design and operation. Therefore including groundwater flow in the design procedure is considered to be essential for thermal and economic sustain ability of the BHE system.

Effect of Underground Building for the Groundwater flow in the Ground Excavation (지반굴착에 따른 지반 안정성 평가 시 지하시설물이 지하수흐름에 미치는 영향 분석)

  • Cha, Jang-Hwan;Lee, Jae-Young;Kim, Byung-Chan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.17-28
    • /
    • 2018
  • The purpose of this study is to investigate the effect of underground facilities around excavation zone on groundwater flow characteristics during excavation. The scenarios were constructed considering the size of the underground facility, the separation distance, and the hydraulic gradient. As a result, as the size of the underground facility increases, the difference of head and the hydraulic gradient become large. The shorter the separation distance of underground facility is, the more the difference of head and the hydraulic gradient occur. The effect of hydraulic gradient on model area was relatively small. As a result of analysis of groundwater flow rate for the scenario, groundwater flow rate tends to decrease as the size of underground facility increases or groundwater flow rate tends to decrease as the separation distance decreases. It is necessary to examine the effect of underground facilities on the groundwater flow analysis in the ground excavation.

Second-order velocity and temperature in pulse tube refrigerators (맥동관냉동기의 2차속도와 온도)

  • Lee, H.J.;Chae, W.B.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.239-248
    • /
    • 1997
  • Steady components and unsteady components of second-order velocity and temperature within pulse tube refrigerators were obtained. Second-order solutions were obtained from the first-order solutions of continuity, momentum and energy equations, assuming that the amplitude of the piston motion is small. The axial temperature gradient was considered in the analysis. The flow direction of the streaming was consistent with previous experimental observations. Effects of axial temperature gradient on secondary flow and second-order temperature were shown.

  • PDF

On Numerical Treatment of Pressure Gradient at the Interface Between a Homogeneous Fluid and a Porous Medium (순수유체와 다공성물질의 경계면에서 압력구배의 수치적 처리에 관하여)

  • Kim I. S.;Nam J. H.;Kim C.-J.
    • Journal of computational fluids engineering
    • /
    • v.4 no.3
    • /
    • pp.28-34
    • /
    • 1999
  • The objective of this study is to present a numerical treatment of the pressure gradient when control volumes are sharing the interface between a homogeneous fluid and a porous medium. Two possible approaches, e.g. linear interpolation and extrapolation, are considered, and they are applied to the case of a steady and two-dimensional curved channel flow which is partially filled with a porous medium. It was found that the linear extrapolation produces a continuous velocity-field at the interface and thus is recommended. On the contrary, the linear interpolation entails a discontinuous velocity field at the interface, thereby warning its use in connection with the Brinkman-Forchheimer-extended Darcy flow model.

  • PDF

Experimental Study on the Characteristics of Water Flow Through Sand Layer (모래층에서의 수류의 특성에 관한 실험적 연구)

  • 남궁달;김철기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3833-3839
    • /
    • 1975
  • The object of this experiment is to find out some flow characteristics of water through sand layer, to prevent moving sands in the filters of the fill Dam, infiltration gallery, well and Deversion Weir. This experiment was accomplished with different particle Sizes of Six Samples and different hydraulic gradient. The results obtained are Summarized as follows. 1. The critical hydraulic gradients for laminar flow was found to be between 1 and 2 when the sand used had the effective diameter, D10 of between 0.18cm and 0.45cm. 2. The critical hydraulic gradients for different particle sizes of sands were varied considerably. 3. There was a negative correlation between critical hydraulic gradient and critical Velocity, and between effective particle diameter D10 and critical hydraulic gradient respectively. 4. In spite of relatively small variation of void ratio of sands used, the values of the coefficient of permeability varied considerably. There was a negative correlation between coefficient of permeability and void ratio.

  • PDF

Prediction of Bypass Transition Flow on Surface with Changing Pressure Gradient (압력구배가 변하는 표면 위의 Bypass 천이 유동의 예측)

  • Baek-Seong-Gu;Chung, Myung-Kyoon;Lim, Hyo-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.823-832
    • /
    • 2002
  • A modified $textsc{k}$-$\varepsilon$model is proposed for calculation of transitional boundary-layer flows with changing pressure gradient. In order to develop the model for this problem, the flow is divided into three regions; pre-transition region, transition region and fully turbulent region. The effect of pressure gradient is taken into account in stream-wise intermittency factor, which bridges the eddy-viscosity models in the pre-transition region and the fully turbulent region. From intermittency data in various flows, Narashima's intermittency function, F(${\gamma}$), has been found to be proportional to $\chi$$^{n}$ according to the extent of pressure gradient. Three empirical correlations of intermittency factor being analyzed, the best one was chosen to calculate three benchmark cases of bypass transition flows with different free-stream turbulence intensity under arbitrary pressure gradient. It was found that the variations of skin friction and shape factor as well as the profiles of mean velocity in the transition region were very satisfactorily predicted.

Enthalpy transport in pulse tube refrigerators (맥동관냉동기의 앤탈피이동)

  • 강영구;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.180-192
    • /
    • 1998
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube is constant. Time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass streaming and enthalpy streaming. Effects of axial temperature gradient, velocity amplitude ratio and heat transfer between the gas and the wall on the steady mass streaming and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF