• Title/Summary/Keyword: gradient coil

Search Result 78, Processing Time 0.036 seconds

A Study on the Pattern Recognition Using Support Vector Fuzzy Inference System (Support Vector Fuzzy Inference System을 이용한 Pattern Recognition 에 관한 연구)

  • 김용균;정은화
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.374-379
    • /
    • 2003
  • 본 논문에서는 pattern recognition을 위하여 support vector fuzzy inference system을 제안하였다 Fuzzy inference system의 structure와 parameter를 identification 하기 위하여 Support vector machine을 이용하였으며 에러 최소화 기법으로는 gradient descent 방법을 사용하였다. 제안된 SVFIS 방법의 성능을 파악하고자 COIL 이미지를 이용한 3차원 물체 인식 실험을 수행하였다.

  • PDF

Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction (회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법)

  • Chung, S.T.;Park, S.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF

Development of Spectrometer with 1 GFLOPs Digital Signal Processors

  • 김휴정;정민영;김치영;고광혁;이상철;이흥규;안창범
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.178-178
    • /
    • 2001
  • 목적: 본 연구에서는 초당 $10^{9}$ 부동점 연산이 가능한 Texas Instrument사의 TMS320C6701 DSP를 이용하여 연속적으로 변하는 경사자계를 real-time으로 계산하여 후, 4 채널의 phase array 코일을 이용하여 영상을 얻은 후 빠른 재구성을 통하여 영상을 확인할 수 있는 spectrometer를 개발하였다. 대상 및 방법: 실시간 구현을 위하여 DSP 보드에 Texas Instruments(Tl)사의 TMS320C6701을 장착하였다. Transmitter, receiver, 그리고 gradient를 담당하는 DSP 보드들과 이들과 연결되어 rf modulation, gradient waveform을 만드는 analog board와 phased array coil을 위한 4 채널까지 측정이 가능한 receiver board로 구성하였다. Gradient 보드의 경우 각 경사자계의 채널(Gx, Gy, Gz)의 sampling points를 real-time으로 각각 계산함으로써 blipped-EPI 뿐만 아니라, 경사자계 파형이 연속적으로 변화하는 spiral-EPI의 실험도 가능하게 하였다.

  • PDF

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

An implementation of the automatic labeling rolling-coil using robot vision system (로봇 시각 장치를 이용한 압연코일의 라벨링 자동화 구현)

  • Lee, Yong-Joong;Lee, Yang-Bum
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.5
    • /
    • pp.497-502
    • /
    • 1997
  • In this study an automatic rolling-coil labeling system using robot vision system and peripheral mechanism is proposed and implemented, which instead of the manual labor to attach labels Rolling-coils in a steel mill. The binary image process for the image processing is performed with the threshold, and the contour line is converted to the binary gradient which detects the discontinuous variation of brightness of rolling-coils. The moments invariant algorithm proposed by Hu is used to make it easy to recognize even when the position of the center are different from the trained data. The position error compensation algorithm of six degrees of freedom industrial robot manipulator is also developed and the data of the position of the center rolling-coils, which is obtained by floor mount camera, are transferred by asynchronous communication method. Therefore, even if the position of center is changed, robot moves to the position of center and performs the labeling work successfully. Therefore, this system can be improved the safety and efficiency.

  • PDF

A Study on the Pressure Loss in Helically Coiled Tubes (나선코일 튜브 내에서의 압력손실에 관한 연구)

  • Han, K.I.;Bark, J.U.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF

Convex Gradient Coils for an Open Magnetic Resonance Imaging System (개방형 자기공명영상시스템을 위한 볼록형 경사자계코일)

  • 문찬홍;박현욱;조민형;이수열
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.129-136
    • /
    • 2000
  • 중재적 시술을 위한 자기공명영상(MRI)용 주자석은 수직 자계를 가지는 경우가 대부분인데 본 논문에서는 수직 자계를 발생하는 주자석에 장착할 수 있는 볼록형 경사자계코일을 소개하였다. 중재적 시술에 필요한 고속 촬영을 하기 위해서는 강한 경사자계 및 낮은 코일 인덕턱스가 필요한데 본 논문에서는 이를 효율적으로 실현하기 위해 경사자계코일을 볼록 곡면 위에 실현하였다. 기존 방법에서처럼 평면 위에 경사자계코일을 실현하지 않고 볼록 곡면 위에 실현함으로써 경사자계코일의 자계 강도 특성 및 코일 인덕턱스 특성을 향상시킬 수 있을 뿐만 아니라 중재적 시술을 위한 경사자계코일 내 공간을 충분히 확보할 수 있다. Prolate spheroid 좌표계에서 표현되는 경사자계코일 면을 정의하였고, 유한요소법을 이용한 볼록형 경사자계코일 설계 방법을 기술하였다. 또한 경사자계코일 면의 곡률에 따라 경사자계코일의 성능이 어떻게 변화하는지에 대한 결과를 제시하였다.

  • PDF

Study on the Implementation of the Digital Controller of High-Speed PWM Current Amplifier (디지털 제어 방식의 고속 PWM 전류 증폭기의 구현에 관한 연구)

  • Ko, Deog-Hwa;Baek, Kwang-Ryul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.2
    • /
    • pp.97-103
    • /
    • 2002
  • This paper deals with a PWM(Pulse Width Modulation) current amplifier using digital controller in order to generate a gradient magnetic field far the MRI(Magnetic Resonance Image) system. Because of tolerance of discrete devices, it is difficult to set accurate values of the control parameters and to make an analog-controlling circuit. However, using digital controller, it is possible to set exact control parameters and to adopt a modern control techniques. It is shown that the digital controller will highly enhance the output current response and it will improve the quality of the MRI.