• Title/Summary/Keyword: good selectivity

Search Result 340, Processing Time 0.029 seconds

Tunable Combline Bandpass Filter Using Cross-Coupled Stepped-Impedance Resonators with Enhanced Characteristics

  • Kim, Yoon-Hong;Cho, Young-Ho;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.4
    • /
    • pp.144-147
    • /
    • 2008
  • This paper proposes a tunable combline bandpass filter with high selectivity, constant bandwidth, and good stopband performances. A filter with these characteristics is obtained by applying cross-coupling to the conventional combline bandpass filter using stepped-impedance resonators(SIRs). For high selectivity and constant bandwidth, cross-coupling is utilized and the SIR configuration is used for enhanced stopband performances. The proposed combline tunable bandpass filter with 5% of fractional bandwidth at 1.6 GHz was fabricated and tested. The measured results showed 11.6% tunability with constant bandwidth, high selectivity and enhanced stopband characteristics.

A Study on the Development of Early Acetone Gas Detection to Prevent the Acetone Leakage Accident (아세톤 누출사고 예방을 위한 아세톤 가스 조기감지 기술개발에 관한 연구)

  • Seung Jin Jeon;Youngbo Choi
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.30-35
    • /
    • 2023
  • Acetone is a widely used Volatile Organic Compound (VOC) in industries and laboratories. However, acetone affects human health adversely and causes fires and explosions. Early acetone detection and improved personnel training in safety and emergency management are necessary to prevent acetone-related accidents. The multi-VOC acetone detectors used currently have a sensitivity and selectivity limit. In this study, we discovered that Pt-loaded iron oxide (a metal oxide semiconductor) conversely, has high detection and selectivity for very low-levels of acetone gas. The loaded Pt catalyzes the reaction between the sensing materials' surface and the oxygen molecules in the air; this optimizes acetone detection and can decrease acetone-related illnesses, fires and explosions.

Characterization of Pervaporation Membranes and Its Operation Parameters for Alcohol Concentration (알코올 농축을 위한 투과증발막의 특성 및 조업변수 연구)

  • 임군택;김현일;김성수
    • Membrane Journal
    • /
    • v.9 no.2
    • /
    • pp.107-113
    • /
    • 1999
  • Alcohol concentration via pervaporation process was performed by using commercial PDMS(polydimethylsiloxane) composite membrane and plasma treated PP(polypropylene) membranes. Effects of operating parameters of pcrvaporation process were examined. With the increase of butanol concentration in the feed, flux and selectivity increased due to the greater affinity of butanol with PDMS than that of water. As the operating temperature increased, free volume as well as the solubilities and diffusivities of alcohol and water increased to result in the greater flux and less selectivity of the membrane. As solubility parameter difference between alcohol and PDMS membrane decreased, high flux and good selectivity were obtained. When PP membrane was plasma treated with methanol, it has 6 times greater flux than PDMS membrane with equivalent separation factor. With the increase of plasma treatment time, flux and selectivity were enhanced. However, excess treatment time caused pore blocking to result in the flux decrease.

  • PDF

Selectivity of Tefuryltrione between Rice and Eleocharis kuroguwai

  • Song, Jong-Seok;Park, Yong Seog;Park, Min-Won;Lee, Jeong Deug;Kim, Do-Soon
    • Weed & Turfgrass Science
    • /
    • v.5 no.4
    • /
    • pp.191-195
    • /
    • 2016
  • Tefuryltrione is a new hydroxyphenylpyruvate dioxygenase (HPPD) inhibitor, which has been recently registered for the use for paddy rice, Korea. Dose-response studies were conducted to compare rice safety and weed control efficacy of tefuryltrione against Eleocharis kuroguwai. When rice and E. kuroguwai were applied at a range of doses of tefuryltrione, $GR_{90}$ values (the dose required to inhibit weed growth by 90%) of E. kuroguwai were $82.38-93.39g\;a.i.\;ha^{-1}$ in two independent experiments. The $GR_{10}$ values (the dose required to inhibit rice growth by 10%) of tefuryltrione for rice were $297.77-471.54g\;a.i.\;ha^{-1}$. As a result, the selectivity indices ($GR_{10}$ for $rice/GR_{90}$ for E. kuroguwai) of tefuryltrione were 3.19-5.72. Therefore, these results demonstrate that tefuryltrione has a relatively high selectivity between rice and E. kuroguwai with a high herbicidal activity against E. kuroguwai and a good rice safety.

ZnO thin film Gas sensors for detection of TMA gas with Pt/Ti thin film heater (Pt/Ti 발열체가 내장된 TMA 가스 측정용 ZnO 박막 가스 센서)

  • 류지열;박성현;최혁환;권태하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.127-135
    • /
    • 1996
  • To increase the sensitivity and the selectivity of the sensors to TMA gas, the composition ratio and the growth conditions of the ZnO films are studied. Annealing of the ZnO films in the various time ranges and temperatures in the oxygen is carried out to enhance the stbility of the electrical resistance. Pt/Ti heater deposited on backside of the substrates in used to control the operating temperature of th esensor. The ZnO thin film sensors doped to 4.0 wt% $Al_{2}$O$_{3}$ 1.0wt.% TiO$_{2}$ and 0.2wt.% V$_{2}$O$_{5}$ exhibited a high sensitivity and an excellent selectivity for TMA gas. The sensors made with the thin films annealed at 700$^{\circ}$C for 60 minutes in the oxygen atmosphere had a good stability and linearity. The heater deposited in the ratio of 1 to 1 (Pt:Ti) had a good heating properties. The sensors fabricated using above conditions showed a good response to the actual gases of a mackerel at a step of deterioration after death.

  • PDF

Pervaporation of Water/ethanol Mixtures Using PVA Membranes Crosslinked with Poly (styrene-maleic anhydride): Study on the Separation Behavior (Poly (styrene-maleic anhydride)로 가교된 Poly (vinyl alcohol)막을 이용한 물/에탄올 수용액의 투과증발: 분리거동에 관한 연구)

  • Kim, Sang-Gyun;Lim, Gyun-Taek;Park, Sang-Wook
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.469-474
    • /
    • 1998
  • Poly (vinyl alcohol) (PVA) membranes crosslinked with poly (styrene-co-maleic anhydride) (PSMAn) have been prepared by the solution method. To investigate the separation behavior of the crosslinked PVA/PSMAn membranes in the pervaporation process, the selective sorption experiment and swelling measurements of the membranes in ethanol-water mixtures of 30~90 wt % ethanol contents were conducted with equipment that was able to measure the concentration and amount of the liquid absorbed in the membranes. The membranes prepared in this study exhibited good selectivity toward water component in sorption and permeation. Also, in the feed containing ethanol more than 50 wt %, the permeation selectivity of the membrane showed better correlation with the sorption selectivity than that with the swelling ratio changing toward the crosslinking content. This behavior was consistence with a solution-diffusion model correlating permeation and sorption selectivity, and led to the conclusion that the permeation selectivity was determined by sorption step rather than by diffusion step in the membrane.

  • PDF

Selectivity Estimation Using Compressed Spatial Histogram (압축된 공간 히스토그램을 이용한 선택율 추정 기법)

  • Chi, Jeong-Hee;Lee, Jin-Yul;Kim, Sang-Ho;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.281-292
    • /
    • 2004
  • Selectivity estimation for spatial query is very important process used in finding the most efficient execution plan. Many works have been performed to estimate accurate selectivity. Although they deal with some problems such as false-count, multi-count, they can not get such effects in little memory space. Therefore, we propose a new technique called MW Histogram which is able to compress summary data and get reasonable results and has a flexible structure to react dynamic update. Our method is based on two techniques : (a) MinSkew partitioning algorithm which deal with skewed spatial datasets efficiently (b) Wavelet transformation which compression effect is proven. The experimental results showed that the MW Histogram which the buckets and wavelet coefficients ratio is 0.3 is lower relative error than MinSkew Histogram about 5%-20% queries, demonstrates that MW histogram gets a good selectivity in little memory.

Direct Conversion receiver adapting DC offset free diode mixer (직접 변환수신기 (direct conversion receiver)에 적합한 DC offset이 없는 주파수 변환기를 채용한 직접변환 수신기의 설계)

  • 박필재;유현규;조한진
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.361-364
    • /
    • 2000
  • One of the problems using DCR(Direct Conversion Receiver) are DC offset, poor channel selectivity. APDP(Anti Parallel Diode Pair) can be good candidate for DCR frequency mixer due to its inherent End harmonic suppression. APDP shows good IP2 and DC suppression. This paper describe single APDP LO power characteristics, IP2, and receiver structure utilizing APDP frequency mixer

  • PDF

The Novel SCN- Ion-selective Electrode Based on the 1-Benzyl-3-(4-nitrophenyl) thio-urea Ionophore

  • Lee, Kyungmi;Kang, Dong Hyeon;Choe, Ju Eun;Yun, Mira;You, Jung-Min;Go, Min Jeong;Lee, Junseong;Jeon, Seungwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3175-3180
    • /
    • 2014
  • A potentiometric sensor based on the 1-benzyl-3-(4-nitrophenyl) thio-urea was synthesized and tested as an ionophore in PVC based membrane sensor towards $SCN^-$ ions. This membrane exhibits a linear stable response over a wide concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-2}M$) with a slope of -59.2 mV/dec., a detection limit of ${\log}[SCN^-]=-5.05$, and a selectivity coefficient for thiocyanate against perchlorate anion of ${\log}K^{pot}_{SCN^-j}=-0.133$. The selectivity series of the membrane is as follows: $SCN^-$ > $ClO_4{^-}$ > $I^-$ > $NO_3{^-}$ > $HSO_3{^-}$ > $Cl^-$ > $HSO_4{^-}$ > $F^-$ > $CH_3COO^-$ > $HCO_3{^-}$ > $Br^-$ > $H_2PO_4{^-}$ > $SO{_3}^{2-}$ > $SO{_4}^{2-}$ > $CO{_3}^{2-}$. The proposed electrode showed good selectivity and a good response for the $SCN^-$ ion over a wide variety of other anions in pH 6.0 buffer solutions and has a fast response time of about < 5s. The influences of the membrane by pH, ionophore, and plasticizer were studied.

Adsorption Characteristics of $CH_4/CO_2$ Mixed Gases on Activated Carbon Fibers (활성탄소섬유상에서 CH4/CO2 혼합가스의 흡착 특성)

  • Moon, Seung-Hyun;Shim, Jae-Woon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.655-662
    • /
    • 2004
  • An adsorption process to recover the pure $CH_4\;and\;CO_2$ from its mixture was examined. In this study, activated carbon fibers were used as a selective adsorbent. The activated carbon fibers has 78~94% micropore volume and 10.5~20.3${\AA}$ narrow pore size, and showed high adsorption rate and the good selectivity for $CO_2$ under the ambient pressure. The ACF with high surface area showed short mass transfer zone and long breakthrough time and, its adsorption capacity depended on the microporosity. Compared with single component adsorption, the amount adsorbed $CO_2$ on ACF increased by the roll-up of $CH_4$ in mixed gases. The adsorption selectivity increased as now rate and $CO_2$ concentration of mixed gases increased, showing 5.2 selectivity for 75% $CO_2$ concentration.