• Title/Summary/Keyword: good bank evaluation

Search Result 17, Processing Time 0.02 seconds

Restoration of Calvarial Defect Using a Variety of Xenogenous Tooth Bone Graft Material: Animal Study (다양한 이종치아 골이식재를 이용한 두개골 결손부 수복: 동물 연구)

  • Kim, Young-Kyun;Kim, Jong-Hwa;Hwang, Ji-Yeon;Um, In-Woong;Jeong, Dongjun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.299-310
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the histological healing process of 3 different types of xenogenic tooth bone graft material and xenogenic bone graft material. Methods: Three types of human tooth bone graft material (chips, crowns, and roots) and BioOss (Geistlich Pharma AG, Wolhausen, Switzerland) was filled at the preformed 4 round-shaped calvarial bone defects of beagle dogs. The beagles were sacrificed at 2, 4, 8, and 12 weeks, respectively, for radiological and histological evaluation. Results: Increased strength and radiopacity were detected in all graft material groups in time-dependent manner. New bone was formed and matured surrounding the graft material histologically. Also, a new bone was directly integrated with graft material. Conclusion: It was expected that newly developed tooth bone graft material would show good bone healing capacity if it was used as a graft material for the restoration of bony defect.

Performance Evaluation for Speed of Mobile Devices in UFMC Systems (UFMC 시스템에서 모바일 장치의 이동속도에 대한 성능평가)

  • Lee, Kyuseop;Choi, Ginkyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • UFMC is known as the one among novel multi-carrier modulation techniques which are designed for replacing OFDM for 5G wireless communication systems. It is the generalized model of OFDM and FBMC, which combines the advantages of OFDM and FBMC and avoids their weak points. UFMC is more robust in synchronization condition like Time-frequency misalignment compared to CP-OFDM. Moreover UFMC is more proper to burst uplink transmission like M2M 5G Communications. In this paper we analyze the BER performance in various channels and speeds. The simulation result shows that the BER performance is lowered when mobile devices are moving fast and the BER performance is so sensitive for the good channel environment.

A Study on Development of Integrated OPAC Based on Hypermedia Techniques (하이퍼미디어 기술에 기반한 통합 OPAC구현에 관한 연구)

  • Ahn, Tae Kyoung;Kim, Hyun Hee
    • Journal of Information Management
    • /
    • v.27 no.1
    • /
    • pp.1-39
    • /
    • 1996
  • The purpose of this paper is to design a model of integrated OPAC called as EconRef. This model not only provides users of libraries with systematic, rapid information service, but also supports librarians to do their tasks effectively. The designed model is constructed based on two operating systems such as REGIS system and The Book House and is developed by using KPWin++ is an expert system shell which combines hypertext and expert system functions. The designed system consists of six modules ; three reference expert systems for document sources, experts and statistical sources; OPAC ; external database ; user's guide. For the evaluation of the designed system, performance of EconRef system is compared with that of the naive and expert reference librarians. And also the features of the system are compared with those of REGIS systems. The tests comparing BconRef system searching with librarians searching have shown that EconRef system is at least as good as searching with expert librarians and much superior to searching with naive librarians.

  • PDF

Evaluation of polyglycolic acid as an animal-free biomaterial for three-dimensional culture of human endometrial cells

  • Sadegh Amiri;Zohreh Bagher;Azadeh Akbari Sene;Reza Aflatoonian;Mehdi Mehdizadeh;Peiman Broki Milan;Leila Ghazizadeh;Mahnaz Ashrafi;FatemehSadat Amjadi
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.4
    • /
    • pp.259-269
    • /
    • 2022
  • Objective: Animal-free scaffolds have emerged as a potential foundation for consistent, chemically defined, and low-cost materials. Because of its good potential for high biocompatibility with reproductive tissues and well-characterized scaffold design, we investigated whether polyglycolic acid (PGA) could be used as an animal-free scaffold instead of natural fibrin-agarose, which has been used successfully for three-dimensional human endometrial cell culture. Methods: Isolated primary endometrial cells was cultured on fibrin-agarose and PGA polymers and evaluated various design parameters, such as scaffold porosity and mean fiber diameter. Cytotoxicity, scanning electron microscopy (SEM), and immunostaining experiments were conducted to examine cell activity on fabricated scaffolds. Results: The MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) assay and SEM results showed that endometrial cells grew and proliferated on both scaffolds. Immunostaining showed cytokeratin and vimentin expression in seeded cells after 7 days of culture. On both scaffolds, an epithelial arrangement of cultured cells was found on the top layer and stromal arrangement matrix on the bottom layer of the scaffolds. Therefore, fibrin-agarose and PGA scaffolds successfully mimicked the human endometrium in a way suitable for in vitro analysis. Conclusion: Both fibrin-agarose and PGA scaffolds could be used to simulate endometrial structures. However, because of environmental and ethical concerns and the low cost of synthetic polymers, we recommend using PGA as a synthetic polymer for scaffolding in research instead of natural biomaterials.

Biological Water Quality Assessments Using Fish Assemblage in Nakdong River Watershed (어류를 이용한 낙동강 수계의 생물학적 수질 평가)

  • Choi, Ji-Woong;Lee, Eui-Haeng;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.254-263
    • /
    • 2007
  • The objective of this study was to evaluate biological water quality using fish assemblages in Nakdong River watershed. We selected 6 sites along the main axis of the river and evaluated the Index of Biological Integrity (IBI), Qualitative Habitat Evaluation Index (QHEI) and chemical water quality during July 2004${\sim}$March 2006. For the study, we applied the 10 metric IBI model, which was developed for national biological water quality criteria. Nakdong River's IBI value averaged 20.8 (n=14) during the study which means poor biological water quality. Physical habitat health at all sites, based on QHEI model, was measured as 110, indicating fair${\sim}$good condition. The habitat health varied depending on the locations sampled. Habitat health in sites 1 and 6 was judged as good, while the health in sites 3 and 4 was $poor{\sim}fair$. Especially, we found the metric values of $M1{\sim}M5$, M7, M10 were low in sites 3 and 4 compared to other sites. In these sites, thus, habitat restoration of substrate composition, riffles, and bank vegetation may be necessary. In the mean time, chemical water quality, based on BOD, COD, TSS, and nutrients, had no large spatial and temporal variations. Overall data analysis indicated that site 3 was largely impacted by the polluted-tributary, Keumho River and the downstreams showed better water quality due to the dilution of the polluted river water by Nam River and Hwang River.

Analysis of Physical, Chemical and Biological Parameters, Based on Long-Term Monitoring (2004 $\sim$ 2007), in Daejeon Stream (대전천 수계의 장기 모니터링 (2004$\sim$2007)에 의한 물리적, 화학적, 생물학적 평가 변수 분석)

  • Lee, Min-Jung;Choi, Ji-Woong;Kim, Hyun-Mac;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.364-373
    • /
    • 2009
  • We evaluated stream health, based on integrative approaches of qualitative habitat evaluation index (QHEI), chemical water quality and the index of biological integrity (IBI) using fish assemblages in Daejeon Stream during August 2004 - October 2007. The QHEI values in this study averaged 78.2 (n=28, range: 47$\sim$124), indicating "fair" condition based on the criteria of US EPA (1993). The highest value was in the headwater site (S1) that was 112 (good), whereas the value in S3, mid and downstream was SS (fair-poor) that was the lowest owing to a disturbance on the bed and an artificial bank. Concentrations of chemical parameters such as BOD, TP and conductivity increased from the upstream to the downstream due to higher inputs of organic matters and nutrients from the urban area. Conductivity and TP showed a dilution of stream water by rainwater during summer monsoon. Analysis of fish compositions showed that total number of species was 24 and Zacco platypus was predominated (82%). The mean IBI was 17 (range: 12$\sim$30) during four years and the IBI values also decreased from S1 to S4. These results indicated that ecological health was degradated distinctly as the stream goes down through the city-center. We concluded that Daejeon Stream running through the city are influenced by chemical impact such as an influx of domestic sewage as well as the quality of habitat.

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.