• 제목/요약/키워드: gold cathode

검색결과 14건 처리시간 0.019초

음극표면 pH 측정에 의한 Ni-P합금의 전착기구 고찰 (Investigation of the mechanism of Ni-P alloy deposition using by in-situ surface pH measurement during electrodeposition)

  • 이규환;장도연;김동수;이상열;권식철;강성군
    • 한국표면공학회지
    • /
    • 제35권2호
    • /
    • pp.93-100
    • /
    • 2002
  • To better understand the codeposition mechanism of phosphorous, surface pH and potential of cathode were measured during electrodeposition of Ni-P alloys. The pH of cathode surface was measured using a flat-bottom glass pH electrode and a 500 mesh gold gauze as cathode. The cathode surface pH was increased with increasing the current density and always higher than the pH in the bulk solution. As a result of overplotting the surface pH and cathode potential on the Pourbaix diagram, it was found that cathode surface shift to the domain of predominant of $H_2$$PO3$-or $H_2$$PO_2$-. Additionally, new deposition mechanism was suggested that $H_2$ $PO_2$- and $H_2$$PO_3$- play important roles in the deposition reaction of Ni-P alloys.

ELECTROLYTIC RECOVERY OF PRECIOUS METALS FROM DILUTED SOLUTIONS

  • Roland Kammel;Lieber, Hans-Wilhelm
    • 한국표면공학회지
    • /
    • 제14권4호
    • /
    • pp.209-214
    • /
    • 1981
  • Electrolytic recovery of gold and silver from diluted solutions has at first been applied nearly 100 years ago. Compared with other recovery techniques electrolytic treatment offers several advantages. But to achieve high space-time yields special constructions of electrolytic cells for improved mass transfer are necessary. Ex-tended cathode surface areas and vigorous agitation are important features. Gold and silver recovery by use of newly developed electrolytic cell constructions - rotating tubular bed reactor and impact rod reactor - has been described. Calculations based on industrial application during several years are confirming that electrolytic recovery of precious metalss from diluted solutions has been operated in a very economic way.

  • PDF

공연비 측정시스템의 산소농도 측정을 위한 센서 개발 (Development of Oxygen Sensor for the Oxygen Concentration Measuring of Air-fuel Ratio Measuring System)

  • 이진휘;장향동;최고열;김양수;조동회;박면용;정구춘;조진원
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.472-477
    • /
    • 1999
  • 연소배기가스의 성분중 산소의 농도를 분석하여 적정연소에 필요한 공기량을 조절 할 수 있는 공연비 측정시스템의 산소센서를 개발하였다. 금환원전극을 이용한 갈바니식 산소센서를 제조하였고, 산소농도 측정범위는 0~30% $O_2$이다. 응답시간은 15~20초로 매우 빠르게 선택적으로 나타내었다. 센서의 재현성 및 안정성 면에서 매우 좋은 결과를 나타내었다.

  • PDF

젖산 연료전지용 효소전극 제작 및 특성 분석 (Fabrication and Characterization of Enzyme Electrode for Lactate Fuel Cell)

  • 장연청;김창준
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.373-378
    • /
    • 2021
  • 본 연구는 땀에 존재하는 젖산을 연료로 사용하여 전기를 생산하는 웨어러블 연료전지용 고전력 젖산 산화효소 전극을 개발하는 데 그 목적이 있다. 유연성 있는 탄소종이 기반의 고정화효소 전극을 제작하고 평가하였다. 전해질 내 젖산농도 증가에 따라 젖산 산화효소(lactate oxidase, LOx)의 촉매작용으로 전류생성량이 증가하였다. 금 나노입자가 부착된 탄소종이에 고정화된 LOx가 탄소종이에 부착된 LOx보다 1.5배 많은 전류를 생성하였다. 빌리루빈 산화효소(bilirubin oxidase, BOD)가 고정화된 cathode는 질소로 퍼지(purge)된 전해질보다 산소로 포화된 전해질에서 높은 환원전류를 발생시켰다. 두 전극으로 구성된 연료전지를 제작하여 방전전류 변화에 따른 셀전압을 측정하였다. 방전 전류밀도 값이 66.7 ㎂/cm2에서 셀 전압은 0.5±0.0 V였고, 셀 전력량은 최대치인 33.8±2.5 ㎼/cm2를 나타내었다.

포도당 센서의 제작을 위한 고정화 방법의 전기화학적 결정 (Electrochemical Determination of Immobilization Technique for Glucose Sensor Fabrication)

  • 정태훈;홍석인;노봉수;정용섭;윤정원;김태진
    • KSBB Journal
    • /
    • 제13권1호
    • /
    • pp.52-57
    • /
    • 1998
  • The present work proposes a simple electrochemical method applicable to any immobilization processes of oxidase using a Clark type oxygen electrode as a base transducer. The present work suggests an optimal immobilization technique among three different methods of glucose oxidase(GOD) onto one side of $37[\mu}$mthick blend membranes, composed o 80% of cellulose triacetate and 20% of polycaprolactone, on the basis of the maximum Michaelis-Menten parameter(Vm) determined by either steady state or transient analyses. The electrode system was made of disk type gold cathode(4mm diameter) and Ag/AgCl anode. One side of the blend membrane was in contact with the cathode surface while the other side was immobilized with GOD either in covalent-bond or cross-linked forms, the latter being covered by $25{\mu}$m thick dialysis membrane of cellulose acetate. The resultant current density was on-line monitored by a potentiostat while glucose level was varied from 1 to 20 mM. The present study shows that direct cross-linking of GOD with glutaraldehyde was mostly preferred for fabrication of glucose sensor, on the basis of resultant kinetic parameters from either steady state or transient analyses.

  • PDF

나노간극에 발생하는 전기방전의 실험적연구 (Experimental Study on Electrical Discharge in Nanoscale Gaps)

  • 이영민;최해운
    • 대한기계학회논문집A
    • /
    • 제35권5호
    • /
    • pp.495-501
    • /
    • 2011
  • 나노간극에서 발생하는 전기방전에 대해서 실험적으로 연구하고 그 결과를 분석하였다. Pt-Ir 합금으로 구성된 음극과 금으로 박막코팅된 양극사이에 전기방전을 하였다. 음극과 양극에서 전기장을 10V~80V 범위에서 제어하였으며, 간극은 50nm 에서 800nm 로 제어하였다. 이때 발생된 전기방전신호, 쇼트신호 등은 간접적으로 나노간극에서 발생하는 현상들을 이해할 수 있었다. 실험결과 전기방전은 전기장과 음극의 전극첨단의 반경에 매우 밀접하게 관련이 있었다. 작은 간극에서 발생하는 전기방전은 비교적 산포도가 크고 랜덤한 형태를 보였으며 음극 전극첨단의 반경에 민감하게 반응하였다.

유한요소해석을 활용한 전자관(Cathod Ray Tube)의 Microphonic 현상개선에 관한 연구 (Reduction of Microphonic Phenomenon in Cathode Ray Tube by Finite Element Analysis)

  • 김성대;서장원;김석관;정봉교
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.271-274
    • /
    • 1996
  • TV나 스피커가 부착되는 PC Monitor에서는 스피커에서 나오는 음향에너지로 인한 진동으로 물결무늬모양의 화면떨림현상이 발생하는데 이를 감소시키기 위해 본 연구에서는 모니터에서의 스피커 부착부분에 대한 개선이 아닌 CRT 자체를 개선하여 어떤 형태의 모니터에 장착하여도 Microphonic현상이 최소화될 수 있는 CRT를 개발하고자 한다. 본 연구에서는 15" CRT를 대상으로 Microphonic현상의 원인규명과 개선안을 도출하였다. Microphonic현상의 주파수분석과 모드분석을 통해 원인을 규명하고 중요부품을 위주로 유한요소해석모델을 구현하였으며 이를 이용하여 중요인자 중 개선이 쉬운 스프링과 프레임에 대한 형상개선을 통해 Microphonic현상수준을 크게 개선하였다. 특히 17" 프레임에 대한 구체적인 개선형상은 실험계획법을 사용하여 도출하였다. 15" GoldStar CRT의 경우는 동일모델에서 최고수준으로 현재 생산 판매되고 있다. 현재 생산 판매되고 있다.

  • PDF

Clark전극에 의한 DO 농도측정을 위한 절전형 센서개발에 관한 연구 (Development of low power type sensor for the DO concentration measurement by clark electrode)

  • 이동희
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권3호
    • /
    • pp.254-260
    • /
    • 1995
  • A method is described for the design and fabrication of the sensor interface circuits on the Clark electrodes for the dissolved oxygen(DO). The discussion includes a method for the +5 V single-supply driving for the sensor circuits, which has low power comsumption for the front-end electronics. DO probe under test is composed of the Clark electrode with silver anode, gold cathode and the electrolyte of half saturated KCI solution and the FEP teflon memtrance for the oxygen penetration. Typical polarograms for the DO probes by using this sensor circuit reveals high accuracy over 99% of the I to V conversion. Partial pressure of oxygen obtained from the polarograms are well suited to the results calculated. It is expected that the proposed sensor circuits can be utilized into the customized IC for the battery-driven small-size DO meters.

  • PDF

침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구 (A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD)

  • 계기성;정재헌;강동완;김병옥;황호길;고영무
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

아황산금나트륨염을 이용한 Au 범프용 금도금층의 표면형상 및 우선적 결정 성장방향 (Surface Morphology and Preferred Orientation of Gold Bump Layer formed by using $Na_3[Au(SO_3)_2]$)

  • 김인수;양성훈;박종완
    • 한국재료학회지
    • /
    • 제5권6호
    • /
    • pp.673-681
    • /
    • 1995
  • 아황산금나트륨염을 이용하여 형성된 약 20$\mu\textrm{m}$ 금도금층의 표면형상 및 우선적 결정 성장 방향에 대하여 전류밀도, 온도, 농도, pH, 교만속도, 금이온농도가 미치는 영향에 대하여 연구하였다. 표면형상은 cathode 근처의 금이온농도가 증가하는 조건[전류밀도(13.0mA/$\textrm{cm}^2$2$\longrightarrow$4.6mA/$\textrm{cm}^2$)], 온도 (3$0^{\circ}C$$\longrightarrow$6$0^{\circ}C$), pH(12.0$\longrightarrow$9.0), 교반효과(Orpm$\longrightarrow$3200rpm), 금이온농도(10g /1$\longrightarrow$l4g/1)으로 갈수록 porous한 조직에서 미세한 조직으로의 변화가 관찰되었다. X선분석에 의하면 금도금층의 결정성장의 주방향은 표면형상과 밀접한 관계를 나타내었으며 표면형상이 미세화되는 조건인 전류밀도(13.0$\longrightarrow$14.6mA/$\textrm{cm}^2$), pH(12.0$\longrightarrow$9.0)는 감소 할수록, 온도(3$0^{\circ}C$$\longrightarrow$6$0^{\circ}C$), 교반속도(0rPm$\longrightarrow$3200rpm), 금이온농도(10g/1$\longrightarrow$g/1)]는 증가 할수록 결정성장의 주회절피크는 (111)에서 (220)으로 그 성장면이 변하고 있음이 조사되었다.

  • PDF