• Title/Summary/Keyword: glucose response

Search Result 645, Processing Time 0.026 seconds

Glucose Tolerance and Insulin Response to Intravenous Glucose Load in Sheep Fed on Germinated Sorghum Grain

  • Achmadi, Joelal;Pangestu, Eko;Wahyono, Fajar
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.10
    • /
    • pp.1575-1579
    • /
    • 2007
  • The glucose tolerance and pancreatic insulin secretion response to glucose in sheep fed on germinated sorghum grain were determined using an intravenous glucose load. Twelve male Thin Tail sheep (an Indonesian native sheep, 12 months old and 14.8 kg average body weight) were divided randomly into sorghum grain-based (S), germinated sorghum grain-based (G) and maize grain-based (C) diets. Sheep were maintained at the same daily intake levels of metabolizable energy and crude protein in the diets throughout the experimental period. After two months of the experimental conditions, each diet group was subjected to an intravenous glucose load experiment in which five doses of glucose (0, 10, 20, 40 and 80 mg/kg BW) were injected to estimate the rate of glucose removal from blood and the pancreatic insulin secretion response. For each sheep and each glucose load dose, the incremental blood serum glucose and insulin concentrations above pre-injection concentration were calculated as serum glucose and insulin response areas. At all glucose doses, sheep fed on S diet had a greater (p<0.05) glucose response area compared to those of sheep fed on G and C diets. Likewise at all glucose doses, the insulin response area was smaller (p<0.05) in sheep fed on S diet than in sheep fed on G and C diets. The glucose and insulin response areas in sheep fed on G and C diets differed slightly. It was concluded that the portion of maize grain in the ruminant ration could be substituted by germinated sorghum grain.

Effects of Consecutive Blood Collecting Stressors on the Plasma Glucose Level and Chemiluminescent Response of Peripheral Blood Phagocytes in Cultured Sea Bass, Lateolabrax japonicus (연속 채혈 스트레스가 양식 농어의 혈장 Glucose 농도 및 말초 혈액내 식세포의 Chemiluminescent 반응에 미치는 영향)

  • Kim, Ki-Hong;Hwang, Yoon-Jung;Cho, Jae-Bum;Ahn, Kyoung-Jin;Kwon, Se-Ryun
    • Journal of fish pathology
    • /
    • v.13 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • The stress of consecutive blood collectings resulted in evident elevation of plasma glucose level and significant lowering of chemiluminescent response of peripheral blood phagocytes in sea bass (Lateolabrax japonicus). Fish responded to the consecutive stressors in cumulative manners. The plasma glucose level in response to consecutive stressors depended on the stressor intervals. When the plasma glucose level of individual fish was compared with the chemiluminescent response, statistically significant (P<0.05) negative correlations existed.

  • PDF

Optimization of Response Characteristics of pH-ISFET Glucose Sensor (완충용액과 효소고정화막의 조성에 따른 pH-ISFET 포도당센서의 감응특성)

  • Lee, Heung Lark;Yang, Seung Tae;Jung, Doog Sook;Kim, Chang Soo;Sohn, Byung Ki
    • Analytical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.177-184
    • /
    • 1992
  • A preparation method and response characteristics of a glucose sensor which consisted of pH-ISFET and glucose oxidase-immobilized membrane were investigated. The pH-ISFET glucose sensor was fabricated by immbilizing bovine serum albumin and glucose oxidase with glutaraldehyde on gate of the pH-ISFET. Effects of pH and concentration of working buffer and enzyme load on the pontentiometric response of the pH-ISFET glucose sensor were examined. Response characteristics for the determination of glucose in synthetic physiological saline solution(pH 7.4) were as follows. That is the concentration range of linear response, slope of linear response(sensitivity), and response time were $1.0{\times}10^{-4}{\sim}6.0{\times}10^{-3}M $, 4.1 mV/decade, and 12~15 min., respectively.

  • PDF

$H_2O_2$ Detection Property of Glucose Sensor using Self Assembled Viologen Modified Electrode as Mediator (Viologen 유도체를 전하전달체로 이용한 Glucose 센서의 $H_2O_2$ 검출 특성)

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.86-87
    • /
    • 2007
  • An amperometric glucose biosensor has been developed using viologen derivatives as electron mediator of glucose oxidase (GOD) at Au electrode. Highly stable self assembled monolayer (SAM) of thiol-based viologen is immobilized onto the Au electrode followed byGOD is immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300 mV. Upon immobilization of glucose oxidase onto the viologen modified-electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance such as, pH, potential were optimized and assessed. This biosensor offered an excellent electrochemical response for glucose concentration below ${\mu}mol$ level with high sensitivity and selectivity and short response time. The levels of the RSD's (< 5 %) for the entire analyses reflected the highly reproducible sensor performance. Using the optimized a linear relationship between current and glucose concentration was obtained up to $4.5{\times}10^{-4}$ M. In addition, this biosensor showed well reproducibility and stability.

  • PDF

The Relationship between Viscosity of Soluble Dietary Fiber and their Hypoglycemic Effects (수용성 식이섬유소의 점도가 혈당강하에 미치는 영향)

  • 김은희
    • Journal of Nutrition and Health
    • /
    • v.29 no.6
    • /
    • pp.615-621
    • /
    • 1996
  • Experiments were carried out in humans to assess the relationship between viscosity and post-prandial glucose response of soluble fibers. Eight(3 male and 5 female) healthy individuals were tested for their glucose response after taking control meals or 3 test fiber meals of different viscosities. Meal viscosity of the test food was adjusted to be between 200 and 70, 000 cps. There was a significant increase in post-prandial glucose response(p=0.01) in control meals by solely increasing the volume of water. Fiber with the highest viscosity konjac mannan demonstrated the lowest relative glucose response(70.1$\pm$6.6), followed by medium viscosity xanthan (79.3$\pm$8.7)and low viscosity psyllium (86.3$\pm$10.5). The difference is significant at the level of p<0.05. However, no significant difference in relative glucose response of the same fiber was found when the 4 levels of water were added to make different meal viscosity of each fiber (p=0.476). This result suggested that hypoglycemic action of soluble dietary fibers is related to fiber viscosity rather than meal viscosity.

  • PDF

Early Gastrin Response to Single Glucose and Casein Feeding (포도당 및 Casein 액 단일투여에 의한 조기 Gastrin 반응)

  • Sung, Ho-Kyung;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.97-101
    • /
    • 1981
  • The early plasma gastrin responses to single oral glucose or casein solution were studied in the same normal subjects on different days. After an overnight fast, glucose or casein solution was ingested within few minutes at the breakfast time. The plasma gastrin responses to these solutions were compared and contrasted with the concentration when the subjects received glucose solution intravenously. Results were as follows: 1) Rapid intravenous glucose infusion did not produce any changes in the plasma gastrin concentration. 2) Plasma gastrin concentration rose and peaked within 10 minutes after an oral liquid ingestion and then decreased substantially by 15 minutes, but remained slightly above fasting levels at 60 minutes. 3) There was no significant difference between the mean plasma gastrin concentrations after glucose of casein ingestion, but each fluid produced a significant increase in serum gastrin above fasting levels. 4) The subjects who produced high plasma gastrin response to glucose solution did so to casein solution. Conversely a low response to one solution reflected a low response to the other solution. 5) From the above results, authors discussed that individual responsibility rather than the sorts of meals is the factor in the determination of the magnitude of the early gastrin response.

  • PDF

Blood Glucose Response to Some Cereals and Determination of Their Glycemic Index to Rice as Standard Food (주요 곡류의 혈당반응 및 쌀기준 혈당지수 측정)

  • 이정선
    • Journal of Nutrition and Health
    • /
    • v.30 no.10
    • /
    • pp.1170-1179
    • /
    • 1997
  • This study was designed to determine blood glucose responses to some cereals produced in Korea. The levels of blood glucose were measured over 2 hours after feeding healthy vounteers with 50g carbohydrate portions. The glycemic index(GI)k and glycemic index-rice(GI-rice) of a food has been defined as : GI=mean of (blood glucose response area of test food/ blood glucose response area of glucose taken by the same indicidual) $\times$100 and GI-rice=mean of (blood glucose response area of test food/blood glucose response area of rice taken by the same individual) $\times$100. The area under the curve is taken to be the area above the fasting value calculated geometrically from blood glucose increments. The GI of barely to glucose as the standard(57$\pm$7) was significantly (p<0.05) lower than those of other cereals whereas the GI of glutinous rice (110$\pm$8) was significantly (p<0.05) higher than other those of cereals. The GI values to rice as the standard were 63 $\pm$6 for barley, 79$\pm$5 for buckwheat, 85$\pm$6 for foxtail millet, 90$\pm$12 for unpolished rice, 100$\pm$0 for rice, 102$\pm$7 for glutinous rice, 106 $\pm$6 for unpolished glutinous rice, 115$\pm$13 for glutinous millet, 116$\pm$13 fro job's tear, and 122 $\pm$ 4 glutinous sorghum. The mean GI-rice was identical to the mean of the adjusted GI values, with a correlation coefficient of r=0.964(p<0.0001). This finding suggests that white rice could be used as standard food for the determination of GI.

  • PDF

Electrochemical Detection of Self-Assembled Viologen Modified Electrode as Mediator of Glucose Sensor

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.106-110
    • /
    • 2009
  • An amperometric glucose biosensor has been developed using viologen derivatives as a charge transfer mediator between a glucose oxidase (GOD) and a gold electrode. A highly stable self-assembled monolayer (SAM) of thiol-based viologen was immobilized onto the gold electrode of a quartz crystal microbalance (QCM) and GOD was immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300mV. Upon immobilization of the glucose oxidase onto the viologen modified electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance, such as pH potential, were optimized and assessed. This biosensor offered excellent electrochemical responses for glucose concentration below ${\mu}$ mol level with high sensitivity and selectivity and short response time. The levels of the RSDs (<5%) for the entire analyses reflected the highly reproducible sensor performance. A linear calibration range between the current and the glucose concentration was obtained up to $4.5{\times}10^{-4}M$. The detection limit was determined to be $3.0{\times}10^{-6}M$.

Enhancement of Electrocatalytic Activity upon the Addition of Single Wall Carbon Nanotube to the Redox-hydrogel-based Glucose Sensor

  • Kim, Suk-Joon;Quan, Yuzhong;Ha, Eunhyeon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.33-37
    • /
    • 2021
  • In electrochemical glucose sensing, the enhancement of the sensitivity and the response time is essential in developing stable and reliable sensors, especially for continuous glucose monitoring. We developed a method to increase the sensitivity and to shorten the response time for the sensing upon the appropriate addition of single wall carbon nanotube onto the osmium polymer-based hydrogel electrode. Also, the background stabilization is dramatically enhanced.

Effects of K or Ca Supplement on Glucose Tolerance and Insulin Response in Subjects with Furosemide Diuresis (Furosemide 이뇨중의 내당능 및 Insulin 반응에 미치는 K 또는 Ca 보충투여의 영향)

  • Sung, Ho-Kyung;Koh, Joo-Hwan;Ryu, Yong-Woon
    • The Korean Journal of Physiology
    • /
    • v.10 no.2
    • /
    • pp.29-37
    • /
    • 1976
  • Effect of furosemide administration on glucose tolerance, insulin-and HGH response following parenteral glucose loading was studied in healthy subjects. Effects of potassium or calcium on the furosemide induced changes were also observed in the same subjects. Furosemide administration resulted in a considerable reduction in the magnitude and duration of insulin response although no obvious changes were observed in glucose disappearance from the circulation. Oral potassium or calcium supplement to the furosemide treated subjects showed a reversion toward normal of the insulin response. The author suggested that a decreased endogenous insulin production resulting from the potassium and/or calcium depletion is responsible for the changes observed. In those subjects who receive parenteral nutrition if administration of furosemide is essential, it should be supplemented by potassium and/or calcium.

  • PDF