• Title/Summary/Keyword: glucose measurement

Search Result 267, Processing Time 0.033 seconds

Application for Measuring the Glucose, Ammonia nitrogen, and Tylosin Concentration using Near Infrared Spectroscopy

  • Kim, Jong-Soo;Cho, Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.19-25
    • /
    • 2008
  • For measurement of tylosin, ammonia nitrogen, and glucose concentration during the culture of Streptomyces fradiae using Near Infrared Spectroscopy, the calibration using various mathematical models was performed and then, based on the linear model, the validation was carried out. In the case of sucrose concentration using the MLR method, the Standard Error of Prediction and Multiple correlation coefficient were 1.97, and 0.991, respectively. In the case of ammonia nitrogen concentration using the PLSR method, the Standard Error of Prediction and Multiple correlation coefficient were 0.13, and 0.990, respectively. In the case of tylosin concentration using the PLSR method, the standard Error of Prediction and Multiple correlation coefficient were 0.54, and 0.984, respectively.

Comparison of Nutrients Intake, Bone Density, Total Cholesterol and Blood glucose in women living in Taegu City (대구지역 성인 여성의 연령별 영양섭취상태, 골밀도, 총 콜레스테롤과 혈당의 비교 연구)

  • Lee, Gyeong-Sun;Kim, Jeong-Mi
    • Journal of the Korean Dietetic Association
    • /
    • v.9 no.1
    • /
    • pp.81-93
    • /
    • 2003
  • This study was performed to compare nutrient intake, bone density, total cholesterol and blood glucose in women who lived in Taegu city. The number of subjects participated in the study was 89 and they were classified into 3 groups by age. 30.3% of the subject were in their 20-34 years of age, 37.1% were in their 35~49 years of age and 32.6% were above fifty. A dietary record method was used to assess the nutritional intake of subjects. Anthropometric measurement such as body weight, height and WHR, and blood pressure, blood glucose, cholesterol and BMD were measured. The results were as follows, mean weight, WHR, SBP, and blood glucose and total cholesterol of the subjects above 50 years old were significantly higher than those of 20-49 years of age(p<0.05). Mean bone density in calcaneus of subjects aged above fifty was lower than those of under 49 years of age(p<0.05). Weight, BMI, waist circumference, WHR and SBP were positively correlated with age(p<0.01). WHR and body fat were positively correlated with BMI(p<0.01). Waist circumference was positively correlated with SBP(p<0.01). Bone mineral density was negatively correlated with age and SBP(p<0.01). Also BMD was positively correlated with weight(p<0.05). Energy intakes was positively correlated with bone mineral density(p<0.05). Fat intakes was negatively correlated with SBP and blood glucose(p<0.05). Calcium intakes was negatively correlated with SBP(p<0.05). Ca/P ratio was negatively correlated with age(p<0.05) and WHR(p<0.01). Zinc intakes was negatively correlated with SBP and blood glucose(p<0.05). From the findings, it is suggested that the women after menopause keep the optimum body weight and good eating habits. Especially intake of good quality protein, calcium and carbohydrate seemed to be important.

  • PDF

The Changes of Soluble Sugar Components and Texture during the Processing of Dried Persimmon (건시제조중(乾枾製造中) 감과실(果實)의 당조성(糖組成)의 변화(變化) 및 물성(物性))

  • Moon, Kwang-Deok;Sohn, Tae-Hwa
    • Journal of the Korean Society of Food Culture
    • /
    • v.3 no.4
    • /
    • pp.385-390
    • /
    • 1988
  • This study was conducted to determine the interconversion of sugars in persimmon during the drying process and the textural properties of raw and dried persimmons using the changes of some chemical constituents, the analysis of sugar component, and the measurement of texture. Five varieties of persimmons were used in this experimment. As the drying proceeded, content of acetaldehyde and alcohol increased while soluble tannin content rapidly decreased. The rapid changes of these component obserbed in kyongsan Bansi and Hiratanenashi. Soluble sugars detected in raw persimmons were mainly glucose, fructose and sucrose. The content of sucrose was rapidly decreased in early stage of drying, while glucose and fructose were rapidly increased. The nearly same amount of glucose and fructose presented in the dried persimmon although there were some differences among varieties tested. The major component of white powder developed on the surface of dried persimmon was almost glucose. The texture profile analysis of the raw and dried persimmons was made with texturemeter and the quality of the dried persimmons was sensory evaluation method. Hiratanenashi and Sagoksi were determined as the suitable varieties in the processing of dried persimmons, but the varieties of Changdungyee and Namyang Susi were not suitable.

  • PDF

A Unified Potentiostat for Electrochemical Glucose Sensors

  • Sohn, Ki-Sung;Oh, Seok-Jae;Kim, Eui-Jin;Gim, Jeong-Min;Kim, Nam-Soo;Kim, Yeong-Seuk;Kim, Jong-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.5
    • /
    • pp.273-277
    • /
    • 2013
  • A unified potentiostat circuit for both $O_2$- and $H_2O_2$- based electrochemical glucose sensors was proposed and its function was verified by circuit simulations and measurement results of a fabricated chip. This circuit consisted of an operational amplifier, a comparator and current mirrors. The proposed circuit was fabricated with a $0.13{\mu}m$ thick oxide CMOS process and an active area of $360{\mu}m{\times}100{\mu}m$. The measurements revealed an input operation range from 0.5 V to 1.6 V in the $H_2O_2$- based bio-sensor and from 1.7 V to 2.6 V in the $O_2$- based bio-sensor with a supply voltage of 3.3 V. The evaluation results showed that the proposed potentiostat circuit is suitable for measuring the electrochemical cell currents of both $O_2$- and $H_2O_2$- based glucose sensors.

Respiratory Activity of Bacteria in Various Concentrations of Glucose (박테리아의 산소소비량에 관한 실험적 고찰)

  • Choi, Hyung-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.134-137
    • /
    • 1977
  • The most efficient method for reducing the organic content of dilute liquid waste is by aerobic-biological treatment. Basically, the organisms responsible for treatment possess the ability to decompose complex organic compounds and to use the energy so liberated for their bodily functions: reproduction, growth, locomotion and so on. That part of organic matter used to produce energy is converted to the essentially stable end products of carbon dioxide, water and ammonia, while the remainder is converted to new cells which can be settled and thus removed from the liquid before the waste is discharged to the receiving body water. Oxygen must be supplied continuously during the aerobic process. In the field of sewage treatment the Warburg respirometer is used mainly for the measurement of the oxygen uptake of samples. In this experiment the Warburg constant volume respirometer was used to determine the oxygen uptake by bacteria in the presence of various glucose concentrations. The rate of oxygen uptake by the bacteria was expressed as the respiratory quotient. The result indicated that the oxygen uptake was proportional to the glucose concentration. The expecting equation of the regression line was Y=7.7+0.12X where Y: respiratory quotient, ${\mu}l.\;O_2$ taken up/mg. dry wt. bacterium/hr. X: concentration of glucose, mg/l

  • PDF

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Wireless Bio-signal Monitoring System (무선 생체신호 모니터링 시스템)

  • Kim, Do-Kyoung;Lee, In-Kwang;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2055-2056
    • /
    • 2011
  • As rapid aging and high economic level, people are interested in their wellness. And it needs to examine the condition of their health constantly. Proposed device can measure bio-signal by connecting several measurement modules such as spirometric module, blood glucose measurement module, uro-flow measurement module and temperature measurement module. These modules can be chosen as occasion demands. In addition, developed user program enables patients to monitor bio-signal at their own place via the personal computer.

  • PDF

Contractile Force Measurements of Cardiac Myocytes Using a Micro-manipulation System

  • Park Suk-Ho;Ryu Seok-Kyu;Ryu Seok-Chang;Kim Deok-Ho;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.668-674
    • /
    • 2006
  • In order to develop a cell based robot, we present a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source. The proposed measurement system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recording system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitudes of the contractile force of each cardiac myocyte under different conditions were compared. From the quantitative experimental results, we could estimate that the force of cardiac myocytes is about $20\sim40{\mu}N$, and show that there are differences between the control cells and the micro-patterned cells.

Enzymatic Desugarization of Egg White for Drying with Glucose Oxidase (Glucose Oxidase에 의(依)한 건조용(乾燥用) 난백(卵白)의 효소적(酵素的) 탈당(脫糖))

  • Song, Kwang Taek;Oh, Hong Rock;Kwon, Soon Ki;Lee, Bong Duck
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.223-232
    • /
    • 1984
  • The influences of some factors involved in removing glucose from egg white by the glucose oxidase system be fore drying were investigated. And the properties between foams prepared from raw and enzyme-treat ed egg white was compared. The results obtained we re summarized as follows; 1. The dianisidine method was found to be suitable for the measurement of egg white glucose in the range up to 100ug/ml. 2. The optimal pH of glucose oxidase activity on glucose was found to be a bout 5.0, and thats activity was most stable in the pH range of about 4.0~5.0 when that enzyme was treat ed for 30 minute at $50^{\circ}C$. 3. The optimal temperature for glucose oxidase reaction on glucose was found to be about $20^{\circ}C$, and that enzyme activity was s table up to $50^{\circ}C$. 4. The removing rate of glucose from egg white with glucose oxidase was influenced by the enzyme concentration, pH and oxygen addition, and the react ion time of the desugarization was about 10 hour sunder the conditions of 0.5% hydrogen peroxide, pH 7.0 and $26^{\circ}C$. 5. All of the each egg white treated with glucose oxidase, glucose oxidase+pancreatin, glucose oxidase+trypsin showed highly foaming ability than that of natural egg white(control), but thats foam stability, on the contrary, was reversed.

  • PDF

Postprandial Asymptomatic Glycemic Fluctuations after Gastrectomy for Gastric Cancer Using Continuous Glucose Monitoring Device

  • Ri, Motonari;Nunobe, Souya;Ida, Satoshi;Ishizuka, Naoki;Atsumi, Shinichiro;Hayami, Masaru;Makuuchi, Rie;Kumagai, Koshi;Ohashi, Manabu;Sano, Takeshi
    • Journal of Gastric Cancer
    • /
    • v.21 no.4
    • /
    • pp.325-334
    • /
    • 2021
  • Purpose: Although dumping symptoms are thought to involve postprandial glycemic changes, postprandial glycemic variability without dumping symptoms remains poorly understood due to the lack of a method that allows the easy and continuous measurement of blood glucose levels. Materials and Methods: Patients having undergone distal gastrectomy with Billroth-I (DG-BI) or Roux-en-Y reconstruction (DG-RY), total gastrectomy with RY (TG-RY) and pylorus preserving gastrectomy (PPG) for gastric cancer 3 months to 3 years prior, diagnosed as pathological stage I or II, were prospectively enrolled from March 2018 to January 2020. The interstitial tissue glycemic levels were measured every 15 min, up to 14 days by continuous glucose monitoring. Moreover, using a diary recording the diet and symptoms, asymptomatic glucose profiles without sugar supplementation within 3 h postprandially were compared among the four procedures. Results: A total of 40 patients were enrolled, 10 patients for each of the four procedures. There were 47 glucose profiles with DG-BI, 46 profiles with DG-RY, 38 profiles with TG-RY, and 46 profiles with PPG. PPG showed the slowest increase with a subsequent gradual decrease in glucose fluctuations, without hyperglycemia or hypoglycemia, among the four procedures. In contrast, TG-RY and DG-RY showed spike-like glycemic variability, sharp rises during meals, and rapid drops. The glucose profiles of DG-BI were milder than those of RY. Conclusions: The asymptomatic glycemic changes after meals differ among the types of surgical procedures for gastric cancer. Given the mild glycemic fluctuations in PPG and the glucose spikes in TG-RY and DG-RY, pylorus preservation and physiological reconstruction without changes in food pathways may optimize postprandial glucose profiles after gastrectomy.