• Title/Summary/Keyword: glucose measurement

Search Result 267, Processing Time 0.027 seconds

A Study on Health Risk Behavior Factors and Chronic Disease Risk Factors

  • SHIM, Su Jeong;LEE, Ji Hee;PAIK, Jean Kyung
    • The Korean Journal of Food & Health Convergence
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • This study classified subjects aged 30 to 64 into normal group, impaired fasting glucose group, and diabetes mellitus patient group based on data from the 6th period of the National Health and Nutrition Examination Survey (2013-2015). Skipping breakfast, lack of physical activity, inadequate sleep time, inadequate weight, excessive drinking, and current smoking are classified as a low health risk group when three or less items are present, and a high health risk group when three or more items are included. By classification, each item included in the physical measurement and biochemical analysis factors and health risk behavior factors was comparatively analyzed. As a result, in the normal group, impaired fasting glucose group, and diabetes group, the average age was higher in the group with high health risk factors than the group with low risk factors, and the male ratio was higher. Body mass index, waist circumference, blood pressure, triglyceride showed a significantly higher result. In the normal group, the fasting blood glucose level and total cholesterol level were also higher in group 2. Therefore, it is thought that it is necessary to control health risk behaviors through lifestyle changes in the normal group, fasting glucose disorder group, and diabetes group.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

Development of Flexible Glucose Measurement Sensor Based on Copper Nanocubes Electroplated Laser Induced Graphene Electrode (구리 나노 큐브를 전기 도금한 레이저 유도 그래핀 전극 기반의 글루코스 측정용 유연 센서 개발)

  • Kim, Geon-Jong;Kim, Taeheon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.413-418
    • /
    • 2018
  • In this paper, we describe the development of a non-enzymatic glucose sensor based on copper nanocubes(Cu NCs) electroplated laser induced graphene(LIG) electrodes which can detect a certain range of glucose concentrations. $CO_2$ laser equipment was used to form LIG electrodes on the PI film. This fabrication method allows easy control of the LIG electrode size and shape. The Cu NCs were electrochemically deposited on the LIG electrodes to improve electron transfer rates and thus enhancing electrocatalytic reaction with glucose. The average sheet resistances before and after electroplating were $15.6{\Omega}/{\Box}$ and $19.6{\Omega}/{\Box}$, respectively, which confirmed that copper nanocubes were formed on the laser induced graphene electrodes. The prepared electrode was used to measure the current according to glucose concentration using an electrochemical method. The LIG electrodes with Cu NCs demonstrated a high degree of sensitivity ($1643.31{\mu}A/mM{\cdot}cm^2$), good stability with a linear response to glucose ranging from 0.05 mM to 1 mM concentration, and a limit of detection of 0.05 mM. In order to verify that these electrodes can be used as flexible devices, the electrodes were bent to $30^{\circ}$, $90^{\circ}$, and $180^{\circ}$ and cyclic voltammetry measurements were taken while the electrodes were bent. The measured data showed that the peak voltage was almost constant at 0.42 V and the signal was stable even in the flexed condition. Therefore, it is concluded that these electrodes can be used in flexible sensors for detecting glucose in the physiological sample like saliva, tear or sweat.

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

The Assessment of Blood Glucose Distribution according to the Fasting State and Glycemic Control Indicators for Diabetes Screening (금식 여부에 따른 혈당치 분포와 당뇨병 선별을 위한 혈당조절지표의 평가)

  • Kwon, Pil Seung;Rheem, Insoo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.312-320
    • /
    • 2016
  • This study analyzed the distribution of the blood glucose level according to the fasting status. Moreover, a relationship was analyzed between fasting blood glucose level and glycemic control indicators. A total of 707 outpatients, who visited Dankook University Hospital, were included and classified into either the fasting group and the non-fasting group. The mean blood glucose level of each group was calculated and analyzed by sex, age, and clinic. In addition, blood glucose, HbA1c, fructosamine, and 1,5-AG were measured in 153 fasting health check-up patients, and the correlation between the blood glucose level and glycemic control indicators was evaluated. Blood glucose averages between the two groups (non-fasting 111.9 vs. fasting 103.6 mg/dL) were different (p<0.05); and the mean difference was lower in women (4.8 mg/dL) than in men (12.2 mg/dL). A significant difference of the median glucose values among the age groups was only observed in the non-fasting group (Kruskal-Wallis test, p<0.01), and not in the fasting group. A 1,5-Anhydroglucitol was estimated to be significantly correlated with the fast blood glucose level in the range of the criteria of impaired fasting glucose (IFG). We presented an assessment of the distribution of blood glucose level in accordance with the fasting status among outpatients, and estimated that 1,5-anhydroglucitol was well correlated with the fasting blood glucose than fructosamine and HbA1c, through the analysis of results of health screening subjects. It is suggested that the use of glycemic indicators that reflect short-term blood glucose control can be used together with the blood glucose measurement in the screening of diabetes mellitus.

Quantitative Analysis of PET Measurements in Tumors (종양학 분야에서 양전자방출촬영을 이용한 정량분석)

  • Choi, Chang-Woon
    • 대한핵의학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.60-65
    • /
    • 2001
  • The positron emission tomography (PET) has been used for the evaluation of the characteristics of various tumors. The role of PET in oncology has been evolved from a pure research tool to a methodology of enormous clinical potential. The unique characteristics of PET imaging make sophisticated quantitation possible. Several quantitative methods, such as standardized uptake values (SUV), simplified quantitative method, Patlak graphical analysis, and Sokoloff's glucose metabolism measurement, have been used in the field of oncology. However, each quantitative method has limitations of its own. For example, the SUV has been used as a quantitative index of glucose metabolism for tumor classification and monitoring response to treatment, even though it depends on blood glucose level, body configuration of patient, and scanning time. The quantitative methods of PET are reviewed and strategy for implementing these methods are presented.

  • PDF

Measurement of Glucose Concentration Using a Bio-Sensor$(\mu{FIAS)}$ (바이오 센서$(\mu{FIAS)}$를 이용한 Glucose 농도 측정)

  • ;Joseph Irudayaraj
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.209-214
    • /
    • 2003
  • 바이오 센서는 생물학적 인식 반응(Biological recognition reaction)이나 생물 촉매 공정(Bio-catalytic process)을 측정 가능한 전기적 신호로 변환시켜주는 적절한 변환기(Transducer)와 같은 생물학적 인식요소로 이루어진 감지 장치를 의미한다. 1962년 효소를 이용한 Glucose 전극봉의 개발이후 이 분야에 대한 수많은 연구와 기기의 개발이 진행되어왔다. 분석도구로써 바이오 센서는 효소, 항체, 수용체, 세포, 조직 등과 같은 생물학적 인식 요소들에 광범위하게 적용 가능하다는 장점이 있는 반면, 위에 열거한 생물학적 인식 요소들의 불안정성으로 인해 신뢰성이 유지되지 못하는 단점을 동시에 지니고 있다. (중략)

  • PDF

Development of Clinical Chemistry Analyzer with the Dry Reagent Strip(I) (건습시약 스트립을 사용한 임상화학분석장치 개발[I])

  • Yoo, Dong-Joo;Jung, Tae-Hwa;Min, Hong-Kee;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.299-306
    • /
    • 1992
  • For quantitative measurement of reflected light from a clinical diagnostic scrip, a prototype of reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate re(leclance parameters. The strop was illuminated at $45^{\circ}C$ through optical fiber and the intensity of reflected light was determined at rectangulat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/dl about glucose, a saturation state of absorbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

The effects of the novel IDPc inhibitor, DA-11004, on NADPH generation, insulin secretion, and glucose level in zucker rats

  • Shin, Chang-Yell;Jeong, Mi-Young;Sohn, Jin-Bup;Lee, In-Ki;Son, Mi-Won;Bae, Cheol-Jun;Byun, Jong-Soo;Kim, Dong-Sung;Kim, Soon-Hae
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.130.3-131
    • /
    • 2003
  • The biological effects of NADPH-dependent isocitrate dehydrogenase (IDPc) inhibitor. DA-11004, was examined in obese zucker rats or streptozotocin-induced diabetic SD rats. Diabetes was induced by injection of streptozotocin (50mg/kg) dissolved in citrate buffer (pH 4.8) into the tail vein and induction of diabetes was confirmed by the measurement of the tail blood glucose level at 48h. DA-11004 (30mg/kg, po) was injected for successive 7days and significantly reduced the plasma glucose in streptozotocin-induced diabetic rats (P<0.05). (omitted)

  • PDF