Evaluation of Glove Designs Applying Change in Hand Length Dimensions by Hand Motion (손동작에 따른 손체표 길이 변화를 적용한 장갑 설계 평가)

  • Kwon, O-Chae;Sun, Mee-Sun;Jung, Ki-Hyo;Lee, Min-Jeong;Yeon, Soo-Min;You, Hee-Cheon;Kim, Hee-Eun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.15-21
    • /
    • 2005
  • Use of a glove made of materials with a low elasticity decreases the performance of the hand such as agility, dexterity, range of motion, and grip strength. The present study examined if the adverse effects of a low-elastic glove can be reduced by a design which accommodates the changes of hand surface lengths by hand motion. Two glove designs which provide patches of elastic cloth and pleats at the finger joints and knuckle were developed by considering the hand surface length changes, and then compared with two conditions(bare hand and conventional glove design that does not consider the dynamic characteristics of the hand dimensions) in terms of completion time in peg board insertion task, maximum grip strength, discomfort in hand motion, discomfort in force exertion, and overall discomfort by 24 right-handed participants. The test results confirmed that wearing of a glove significantly reduced the agility and grip strength capability of the hand and indicated that the novel designs were effective to lessen the performance decreases compared to the conventional design. Also, of the glove designs, the pleat glove design was found most preferred for both better hand performance and less subjective discomfort.

Knitted Data Glove System for Finger Motion Classification (손가락 동작 분류를 위한 니트 데이터 글러브 시스템)

  • Lee, Seulah;Choi, Yuna;Cha, Gwangyeol;Sung, Minchang;Bae, Jihyun;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.3
    • /
    • pp.240-247
    • /
    • 2020
  • This paper presents a novel knitted data glove system for pattern classification of hand posture. Several experiments were conducted to confirm the performance of the knitted data glove. To find better sensor materials, the knitted data glove was fabricated with stainless-steel yarn and silver-plated yarn as representative conductive yarns, respectively. The result showed that the signal of the knitted data glove made of silver-plated yarn was more stable than that of stainless-steel yarn according as the measurement distance becomes longer. Also, the pattern classification was conducted for the performance verification of the data glove knitted using the silver-plated yarn. The average classification reached at 100% except for the pointing finger posture, and the overall classification accuracy of the knitted data glove was 98.3%. With these results, we expect that the knitted data glove is applied to various robot fields including the human-machine interface.

Development of a Data Glove for Rehabilitation Robot for Upper Extremity Paralysis (상지마비 재활훈련로봇용 데이터글로브의 개발)

  • Park, C.Y.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.45-49
    • /
    • 2009
  • This paper proposes a data glove for a rehabilitation robot interface for the upper extremity paralysis. The designed data glove uses seven flexible sensors so as to measure the flexion angles of fingers and wrist. We verified the performance of the data glove using a 3D graphic interface developed. The experimental results show that the proposed data glove is feasible to sense hand motions and applicable to the robot interface.

  • PDF

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

Performance of Conductive Gloves When Using Electronic Devices in a Cold Environment - Manual Dexterity, Usability and Thermoregulatory Responses - (겨울철 전자 기기 사용을 위한 전도성 보온장갑의 착용성 평가 - 손의 기민성과 사용성, 체온조절 반응을 중심으로 -)

  • Kwon, JuYoun;Jung, Dahee;Kim, Siyeon;Jeong, Wonyoung;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.686-695
    • /
    • 2020
  • The present study evaluated the manual dexterity and usability of conductive gloves when operating touchscreen devices in the cold. Twelve male subjects (23.3±1.5 years in age) participated in three experimental conditions: no gloves, fabric conductive and lambskin conductive gloves. Manual dexterity was tested using both Purdue Pegboard (PP) and ASTM dexterity tests at an air temperature of 5℃ and air humidity of 30%RH. Glove usability was tested through the following touchscreen tests: tap, double tap, long tab, drag, flick, and multi-touch. The results showed that manual dexterity according to the PP (2.5 mm of a pin diameter) and ASTM tests (8 mm of a stick diameter) was worse for the two glove conditions than for the no glove condition (p<.005). PP dexterity was better for the fabric glove condition than for the lambskin glove condition (p<.05); however, there was no difference in ASTM dexterity between the two glove conditions. Hand and finger skin temperatures were higher for the glove conditions than the bare hand condition (p<.05), with no differences between the two glove conditions. The touchscreen usability was the best for the no glove condition, followed by fabric gloves (p<.05). Wearing either fabric or lambskin gloves diminishes hand dexterity while maintaining hand and finger temperatures at higher levels. For improved hand dexterity in dealing with small numbers, letters on a touchscreen in cold environments, we recommend wearing fabric conductive gloves rather than lambskin conductive gloves.

Performance Enhancement of A Massive Scientific Data Visualization System on Virtual Reality Environment by Using Data Locality (Data Locality를 활용한 VR환경에서의 대용량 데이터 가시화 시스템의 성능 개선)

  • Lee, Se-Hoon;Kim, Min-Ah;Lee, Joong-Yeon;Hur, Young-Ju
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.284-287
    • /
    • 2012
  • GLOVE(GLObal Virtual reality visualization Environment for scientific simulation)는 컴퓨팅 자원의 성능 향상으로 데이터 양이 급속히 증가한 응용 과학과 전산 시뮬레이션 분야의 대용량 과학 데이터를 효율적으로 가시화하여 분석하기 위한 도구이다. GLOVE의 데이터 관리자인 GDM(GLOVE Data Manager)은 대용량 데이터의 분산 병렬 가시화를 위해 분산 공유 메모리를 제공하는 GA(Global Array)를 이용해 테라 바이트 단위의 데이터를 실시간으로 처리한다. 그러나 대용량 과학 데이터를 가시화 하는 과정에서 기존의 Data Locality를 고려하지 않은 데이터 접근 방식으로 인한 성능 저하를 확인했다. 본 논문은 기존 GLOVE에서 발견한 성능 저하 현상을 밝히고, 이에 대한 해결 방법을 제시한다.

Development and Performance Test on the 1-Inch Glove Valve for the LNG Piping System (LNG 배관 시스템용 1인치 글로브 밸브 개발 및 성능실험)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • This study describes the development of a 1-inch cryogenic glove valve for an LNG pumping system and localization development achieved through the performance test. The cryogenic valve used in the LNG pumping system plays an important role in maintaining a flow rate by LNG transportation. This trial manufactured goods, which was achieved through reverse engineering and developing the assembly process. The result of the leak test satisfied the internal pressure condition using the 78-bar normal temperature test and maintained the anti-leakage condition. Also, the result of the cryogenic leak test (BS 6364: low temperature test procedure) maintained anti-leakage at -196 and 52 bar, which satisfied the test standards.

GLOVE: Distributed Shared Memory Based Parallel Visualization Tool for Massive Scientific Dataset (GLOVE: 대용량 과학 데이터를 위한 분산공유메모리 기반 병렬 가시화 도구)

  • Lee, Joong-Youn;Kim, Min Ah;Lee, Sehoon;Hur, Young Ju
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.6
    • /
    • pp.273-282
    • /
    • 2016
  • Visualization tool can be divided by three components - data I/O, visual transformation and interactive rendering. In this paper, we present requirements of three major components on visualization tools for massive scientific dataset and propose strategies to develop the tool which satisfies those requirements. In particular, we present how to utilize open source softwares to efficiently realize our goal. Furthermore, we also study the way to combine several open source softwares which are separately made to produce a single visualization software and optimize it for realtime visualization of massiv espatio-temporal scientific dataset. Finally, we propose a distributed shared memory based scientific visualization tool which is called "GLOVE". We present a performance comparison among GLOVE and well known open source visualization tools such as ParaView and VisIt.

Electronic Music Glove Using Sound Card (사운드 카드를 이용한 전자 음악 장갑)

  • 정의필;이창원
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.128-133
    • /
    • 2002
  • We developed a electronic music glove (BMG) system that plays musical scores in real time processing. The EMG system interfaces with the signal coming from the controller to the sound card in the computer, The computer, according to the status of the fingers and foot switches, generates the sound signals and sends them to the speaker systems through the application C++ program and MIDI message. The EMG systems control the velocity and duration of sound and several musical performance expressions such as chorus, reverberation, rhythm, and volume. Finally, we implemented the digital drum set using: the EMG system as example.