• 제목/요약/키워드: glove

검색결과 321건 처리시간 0.032초

한국인을 위한 장갑 패턴 고찰 (2) - 장갑 원형 설계를 중심으로 - (A Study on the Pattern-making for Korean Glove - Focusing on Pattern-making for Glove -)

  • 류경옥
    • 복식문화연구
    • /
    • 제17권6호
    • /
    • pp.981-991
    • /
    • 2009
  • The purpose of this study was to develop the pattern-making for Korean glove. To develop the pattern-making for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over th 15 years) were interviewed on the method of glove. The results of regression analysis(hand data) were as follows (unit: cm): wrist thumb tip length = middle finger length + 3.22, hand bread = 1.25 $\times$ middle finger length + 2.18, middle finger breadth at dist = 0.23 $\times$ index finger circumference + 0.4, maximum hand circumference = 3.15 $\times$ index finger circumference + 4.13, middle finger circumference = 0.91 $\times$ index finger circumference + 0.47, maximum hand thickness = 0.69 $\times$ index finger circumference -0.02. Hand measurements for glove pattern-making were developed: There were palmar hand length, hand circumference, index finger circumference and middle finger length.

  • PDF

감성 학습 방식을 위한 무선 RFID 장갑 시스템 (Wearable Wireless RFID Glove System for Emotional Learning Method)

  • 박현식;김성수;정경권
    • 산업경영시스템학회지
    • /
    • 제32권4호
    • /
    • pp.241-247
    • /
    • 2009
  • In this paper, we present a wireless RFID glove in emotional learning method. The proposed wireless RFID glove consists of three parts: RF wireless module, RFID reader, and RFID tags. Objects tagged with a small passive RFID tag, can be sensed at short ranges by using wireless RFID glove. We describe the wireless RFID glove prototype, and present some interactive learning programs and games. The proposed system can be utilized to analyze user activities and train the brain of old person.

겨울철 전자 기기 사용을 위한 전도성 보온장갑의 착용성 평가 - 손의 기민성과 사용성, 체온조절 반응을 중심으로 - (Performance of Conductive Gloves When Using Electronic Devices in a Cold Environment - Manual Dexterity, Usability and Thermoregulatory Responses -)

  • 권주연;정다희;김시연;정원영;이주영
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.686-695
    • /
    • 2020
  • The present study evaluated the manual dexterity and usability of conductive gloves when operating touchscreen devices in the cold. Twelve male subjects (23.3±1.5 years in age) participated in three experimental conditions: no gloves, fabric conductive and lambskin conductive gloves. Manual dexterity was tested using both Purdue Pegboard (PP) and ASTM dexterity tests at an air temperature of 5℃ and air humidity of 30%RH. Glove usability was tested through the following touchscreen tests: tap, double tap, long tab, drag, flick, and multi-touch. The results showed that manual dexterity according to the PP (2.5 mm of a pin diameter) and ASTM tests (8 mm of a stick diameter) was worse for the two glove conditions than for the no glove condition (p<.005). PP dexterity was better for the fabric glove condition than for the lambskin glove condition (p<.05); however, there was no difference in ASTM dexterity between the two glove conditions. Hand and finger skin temperatures were higher for the glove conditions than the bare hand condition (p<.05), with no differences between the two glove conditions. The touchscreen usability was the best for the no glove condition, followed by fabric gloves (p<.05). Wearing either fabric or lambskin gloves diminishes hand dexterity while maintaining hand and finger temperatures at higher levels. For improved hand dexterity in dealing with small numbers, letters on a touchscreen in cold environments, we recommend wearing fabric conductive gloves rather than lambskin conductive gloves.

데이터 글로브를 이용한 3차원 손동작 인식 (3-D Hand Motion Recognition Using Data Glove)

  • 김지환;박진우;;김태성
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2009년도 학술대회
    • /
    • pp.324-329
    • /
    • 2009
  • Proactive computing의 핵심 기술인 손동작 인식 (Hand Motion Recognition, HMR) 기술은 인간과 컴퓨터 사이의 상호작용(Human Computer Interaction, HCI) 분야에서 많은 연구가 진행되고 있다. 본 연구에서는 3축 가속도 센서를 부착한 data glove를 제작하고, 3차원 손 모델을 구현한 후, 이를 이용한 손동작 인식 기술을 개발하였다. Data glove는 가상현실에 대한 입력 장치로써 본 논문에서는 3축 가속도 센서를 사용하여 획득된 신호를 wireless communication으로 PC에 전송할 수 있도록 구현하였다. 손 모델링은 ellipsoid를 이용한 kinematic chain 이론 바탕의 3차원 손 모델을 구현하였으며, data glove에서 얻어진 가속도 정보에 rule 기반의 알고리즘을 적용하여 구현된 3차원 손 모델을 통하여 간단한 손동작(가위, 바위, 보)을 인식하였다.

  • PDF

소아 서혜탈장의 진단시 Silk-glove test의 유용성에 대한 연구 (Effectiveness of Silk-glove Test in the Contralateral Exploration of Inguinal Hernia in Children)

  • 구본용;김재천;정연준
    • Advances in pediatric surgery
    • /
    • 제12권1호
    • /
    • pp.11-16
    • /
    • 2006
  • Inguinal hernia is one of the most common surgical diseases in pediatric patients. But the management of the side opposite the clinically apparent inguinal hernia, the "silent side" is controversial. Four hundred fifty-eight cases of pediatric inguinal hernias, operated by one pediatric surgeon at the Divisionof Pediatric Surgery, Department of Surgery, Chonbuk National University Hospital from January 1998 to December 2002, were reviewed retrospectively to determine the characteristics and significances of the silk-glove test on the side opposite the clinically apparent inguinal hernia. Males were preponderant as 2.8:1. Allhernias were of the indirect type and were repaired by high ligation of the sac. There were 238 (52.0 %) right sided hernias, 160 (35.0 %) were on the left and 60 (13.0%) were bilateral. The number of patients with a positive silk-glove sign on the contralateral side was 158(39.7 %), and 133 of these had a contralateral patent processus vaginalis. Positive predictive value of Silk-glove test was 84.2 % (133/158). The silk-glove test is a simple, safe, and relatively accurate method for contralateral exploration in the unilateral inguinal hernias in children.

  • PDF

장갑의 치수규격 실태에 관한 연구 - KS와 ISO 치수체계를 중심으로 - (A Study on Actual Conditions of Glove Size Standards - Focused on KS and ISO Sizing System-)

  • 김은경;최혜선
    • 복식
    • /
    • 제54권6호
    • /
    • pp.77-90
    • /
    • 2004
  • The purpose of this study was to provide basic information requisite in the new sizing system for gloves. KS glove standards' size dimensions, size designation and labeling systems were analyzed. Also, KS glove standards' control sizes were compared to the anthropometric data of 824 Korean adults taken in the previous study. As well, the ISO hand size system was also compared to the anthropometric data of the previous study according to frequency tables of hand length and hand circumference. The size dimensions showed differences among KS standards and there was no size designation and labeling systems existed in KS standards. Among KS glove size systems, protective rubber gloves for radioactive contamination and surgical rubber gloves' size which followed ISO system were accurately indicate the hand size of the person a glove is intended to fit. ISO glove sizing system comprised the control dimensions of hand length and hand circumference. The coverage of ISO size A was 84.8% which was highest among ISO size A. B, C. And in hand circumference 178, 191, 203, 216mm showed the frequencies above 3% and in hand length 167, 175. 183, 191, 199mm showed the frequencies above 3%.

수술용 장갑의 천공률에 대한 연구 (Incidence and Risk Factors for Surgical Glove Perforation)

  • 유선주;임영신;김명숙
    • 임상간호연구
    • /
    • 제16권3호
    • /
    • pp.63-71
    • /
    • 2010
  • Purpose: This study was conducted to evaluate the incidence and risk factors for surgical glove perforation during operation. Methods: During the month of december 2008, a total of 1,400 pairs of surgical gloves used in major operations was collected in a tertiary hospital. All gloves were examined immediately after operation using the standardized water-leak method to detect any perforation. Incidence of the glove perforation was counted according to the type of operation, operation time, the number of involved personnel, perforation sites, and the manufacturing companies. Results: Out of 2,800 gloves examined, 312 perforations were detected comprising 11.1% of samples. In terms of the type of operation, the perforation incidence varied from 5% to 20%, and the perforation rates in CS (20%) and NS (18%) (p<.001) were significantly higher than those in other departments. The 1st assistant or scrub nurse got glove perforation more frequently than the 2nd assistant or operator (p<.001). Longer operation time was associated with higher incidence of perforation evidently (p<.001). In terms of the sites, the thumb and index finger were more frequently perforated than other sites (4.1% and 3.4% respectively) without any differences between left and right side. Conclusion: Risk factors for glove perforation including the department of operation, operation time, participating personnel, and location of perforation should be taken into account to improve surgical safety.

1인치 볼 밸브 및 글로브 밸브에 대한 개도율에 따른 손실계수(k) 비교에 관한 연구 (Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio)

  • 강창원;이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제20권9호
    • /
    • pp.63-69
    • /
    • 2021
  • This study aims to determine the flow characteristics of a one-inch small ball valve and glove valve used in industrial plants. The flow was changed through an experimental equipment, and the internal flow characteristics of the valves were compared. Considering the pressure drop, the decrease in the slope of the ball valve based on the degree of the valve opening was relatively greater than that of the glove valve; further, the slope of the glove valve was gentle while the pressure drop was high. The flow velocity of the ball valve remains consistent after the valve was opened by 70%, whereas the flow velocity of the glove valve constantly increased. The valve loss factor of the ball valve was relatively low compared with that of the glove valve. When the valve was opened by 20%, which is the beginning stage of the valve opening, the valve loss factor of the ball valve was high and gradually became low. This is a structural problem of the ball valve, and the loss factor is significant because the flow path installed at the ball valve has a considerably small area. However, the overall loss factor of glove valve is high because it has a complicated structure of flow path.

Review on Prevalence, Risk Factors, and Research Advancements on the Use of Medical Gloves Concerning Hand Dermatitis Among Health Care Workers

  • Jeevasunthari Gunasegaran;Ying-Ying Teh;Chin-Keong Lim;Shiow-Fern Ng
    • Safety and Health at Work
    • /
    • 제15권2호
    • /
    • pp.129-138
    • /
    • 2024
  • The COVID-19 pandemic has led to a significant surge in glove usage, as recommended by the World Health Organization. Despite efforts to ensure the quality and safety of gloves, glove-associated skin diseases such as hand dermatitis have become ubiquitous, particularly among health care workers. This review discusses the prevalence, causes, and risk factors of hand dermatitis, as well as research efforts in medical gloves in the past decade to overcome glove-related hand dermatitis. Research papers from 2013 to 2022 were reviewed, selecting only 49 relevant papers from the Ovid, PubMed, and Scopus databases. The average prevalence of hand dermatitis among health care workers increased from 21.08% to 37.24% upon the impact of the COVID-19 pandemic. The cases are likely due to allergies to latex proteins, rubber additives, and accelerators commonly found in gloves. Using alternatives to latex gloves, such as accelerator-free and latex-free glove options, can help reduce allergy-induced hand dermatitis. Strict hand hygiene practices, such as frequent hand washing and the use of sanitizers, are also contributing factors in contracting hand dermatitis. Over the past decade, glove research advancements have focused mainly on reducing or immobilizing latex proteins. These include the use of biodegradable dialdehyde, sodium alginate, arctigenin, bromelain, papain, UV-LED, prototype photoreactors, and structure-modified nanosilica with silane A174. Two effective hand dermatitis preventive measures, i.e. an additional layer of glove liners and the use of gentle alcohol-based hand sanitizer, were recommended. These advancements represent promising steps towards mitigating hand dermatitis risks associated with glove usage.