• Title/Summary/Keyword: glasses lens

Search Result 80, Processing Time 0.026 seconds

A Study of the Power of Glasses Lens and that of Trial Lens (안경렌즈와 굴절측정렌즈의 굴절력 관계에 대한 연구)

  • Kim, Jin Koo;Kang, Myung Gi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.263-267
    • /
    • 1998
  • Today's diopter of optical lens can reveal the derivation apparently compared with that of refraction measure lens. First, this is applicable when there is a difference in the shape and thickness basically and when the lens is used for a short distance. When measure and use it, an astigmatic difference is occurred by the discordant light passage. This is also applicable to optical lens with prism diopter lens and in some cases, must be corrected relating to the diopter incidently.

  • PDF

Next Generation Non-Glasses 3D Stereoscopic Monitors and Spatial Information (차세대 무안경 3D 입체 모니터와 공간정보)

  • Lee, Seun-Geun;Jeon, Young-Jae;Lee, Dong-Cheon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.81-85
    • /
    • 2010
  • Recently, 3D stereo movies, 3D TV broadcasting, and stereoscopic monitors become hot issue. Worldwide engagement in an intense competition for stereo viewing technology just begins. Photogrammetry is the originator of dealing obtaining stereo imagery, processing and display. Non-glasses stereo monitors will replace existing monitors in near future. This study introduces real 3D stereo viewing methods of geospatial data on the non-glasses stereoscopic monitors.

  • PDF

Mechanical properties of materials for spectacle lens cutting containing SrO as Ophthalmic Dispensing Glasses (조제가공을 위한 SrO 첨가 안경렌즈 절삭용 재료의 기계적 특성)

  • Lee, Young-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.197-202
    • /
    • 2004
  • The aim of this work is to improve the mechanical properties of materials for glasses lens cutting at $1920^{\circ}C$ using SrO as sintering additive. The heating rate was $15^{\circ}C/min$ and the cooling rate about $25^{\circ}C/min$ from the sintering temperature to $1000^{\circ}C$. SEM analysis and XRD of the surface of samples were carried out. Microstructures of sintered materials were strongly dependent on the composition of sintering additives. The fracture toughness and hardness were increased by increasing the SrO. Typical fracture toughness and hardness of materials for glasses lens cutting were $5.6{\pm}0.3MPa{\cdot}m^{1/2}$ and $16.2{\pm}0.5GPa$, respectively.

  • PDF

Selection of Optical Glasses Using a Chromatic-Aberration Correction Method for the Whole Visible Range Plus a Telecentric Lens Design Applying the Method (가시광선 전대역의 색수차보정을 위한 광학유리의 선정과 이를 적용한 텔레센트릭 렌즈의 설계)

  • Yu, Seung Moon;Jung, Mee Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.4
    • /
    • pp.217-225
    • /
    • 2015
  • This paper shows the best selection and combination of glass in lens design, to correct a chromatic aberration using achromatic and apochromatic conditions. Using this research result, we have designed a telecentric lens for machine vision in the full range of visible light. We obtain good optical quality in the form of a quite small RMS wavefront error of $0.057{\lambda}$ in the super-broadband wavelength range 380 nm -780 nm. This result is better than that for a common telecentric lens in the visible wavelength range 486.1-656.2 nm.

Influence of Gaming Display and Wearing Glasses on Perceived Characteristics, Presence, and Fatigue (게임 디스플레이 종류와 안경착용 여부에 따른 영상의 인지된 특성, 프레즌스 그리고 피로도의 차이)

  • Lee, Hyunji;Chung, Donghun
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.1004-1013
    • /
    • 2012
  • 3D images and videos are required viewers to wear 3D glasses. According to the data, about half of Korean people wear glasses or contact lens and this implies 3D video viewers may have a trouble due to putting a pair of 3D glasses atop their glasses. The purpose of this study is to examine gamers' perceived characteristics, presence, and fatigue according to video gaming display (2D vs. 3D) and glasses whether wearing or not. The results show that the interaction effect of the display and wearing glasses was statistically significant in the perceived presence, and the main effect of the display was statistically significant in the perceived characteristics and fatigue.

An Research on Ultra Precisive Polishing Manufacturing Technology of Glass for Micromini and Super Wide-Angle Aspherics Glasses Lens. (초소형 초광각 비구면 유리렌즈의 초정밀 연삭가공기술에 관한 연구)

  • Kim, Doo-Jin;Yoo, Kyung-Sun;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.275-281
    • /
    • 2010
  • This research's goal is to process directly aspherics with big sagment and thin center thickness. If we can process directly aspherics with big sagment and thin center thickness, we think it greatly helps to reduce the time of developing optical system. We made very thin glass using diamond grinding whetstone regarding the trace of tool and the detailed drawing of tool super precisive aspherics that has 0.46mm center thickness and over $30^{\circ}$ segment, $0.1{\mu}m$ machining accuracy, 15nm surface accuracy. We think this research's result will be effective to open new market because it is applied not only cell phone optical system but also CCTV robot optical system, internet phone optical system. Also we expect to enhance the super strong brittle precisive process's possibility with super precisive processing technique that achieves 0.46mm glass center thickness as first in the world.

A Study on the Prescription of Size Lens for Myopic Aniseikonia (근시성 부등상시의 등상시 렌즈 처방에 관한 고찰)

  • Kwon, Young-Seok;Kim, Ki-Hong;Lee, Hyun-Mee;Chu, Byoung-Sun;Kwon, Yun-Kyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.555-560
    • /
    • 2013
  • Purpose: The aims of this study were to investigate the stereoacuity and subjective symptoms of aniseikonia with prescription of the size lens. Methods: Participants were myopic anisometropia patients with the binocular refraction difference between 1.75 D~3.50 D. Inclusion criteria of participants were no ocular pathology, no amblyopia, more than 1.0 of corrected visual acuity. With fully corrected spectacles and a correction with the size lens, Awaya aniseikonia test and Randot Stereo test were conducted respectively. In addition, subjective symptoms were also examined using questionnaire. Results: As the anisometropia increased, the aniseikonia increased. Under the anisometropia with same refractive correction was different for each individual. The prescription of size lens caused less aniseikonia than the general prescription of glasses. In addition, prescription of the size lens improved stereoacuity and relieved the symptoms of asthenopia. Conclusions: The prescription of size lens that can correct aniseikonia with prescription of glasses can improve stereoacuity and reduced asthenopia.

Measurement dose of Dental Panoramagraphy using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 파노라마 검사의 피폭선량 측정)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2624-2628
    • /
    • 2011
  • Exposed dose of a patient was measured by Radiophotoluminescent Glass Rod Detector with a use of a panorama graphic device in dental examination. The effect of exposed dose in optic lens was measured by comparing the different materials of the glasses. Depending on the dental location, the exposed dose distribution was 82.4~2,340uSv. It showed that the maximum difference in dose distribution was over 300%. Thus, when manufacturing the devices, it seemed to require shortening the pre-heat time and additional shielding in order to control the diagnosis and exposed dose. The measurement data of the exposed dose in optic lens was increased 20~75uSv per each test when compared putting on glasses with not wearing. As a result, taking off the glasses is recommended to improve efficiency of the test and minimize the exposed dose during dental panorama graphic examinations.