• Title/Summary/Keyword: glass pipe

Search Result 104, Processing Time 0.023 seconds

A study on the Use of Low and Wet Land By Underdrainage(1) (암반비수에 의한 저온지이용에 관한 연구(1))

  • 주재홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.2
    • /
    • pp.1454-1459
    • /
    • 1968
  • Althow underdrainage has been studied for long time, it is the first attempt in Korea to execute using PVC(Plastic) suction pipes in the low and wet field. First, an execution plot and a control plot were set, and the drainage method and soil temprature in the excuted plot have been examined. The growth of crops and the yeild, the improvement of soil and water quality of irrigation are to be dealt during the next experimental period. The experimental method and the results obtained through the experimentations are as follows: Method 1) Depth: 1meter. interval: 5meters Trench was performed by labor. 2) PVC(plastic) sucking pipe filters were wound with glass nylon. 3) Two. horizontal looks were set in the 5a. plot. Results 1) The soil temprature in the excuted plot went up by $1.2^{\circ}C$ in average than in the control plot during the two years(1966-67) of irrigation period, and the maximum temprature raised a day was $3^{\circ}C$ 2) The under ground water level in the executed plot went down by 45cm. 3) The yield increases were 64% in potato, 57% in barley, and 21% in rice. The yield, soil, and the quality of irrigated water will be experimented during the next experemental period.

  • PDF

Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes (세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성)

  • Son, Chang-Hyo
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • An experimental study to investigate the condensing heat transfer characteristics of small diameter horizontal double pipe heat exchangers with R-22 and R-410A was performed. Experimental facility was constructed to calculate and observe HTC(heat transfer coefficients), flow patterns and pressure drop. The main components include a liquid pump, an evaporator, a condenser(test section), a sight-glass, pressure taps and measurement apparatus. Two pipes of different diameters are tested; One 5.35 mm ID 0.5 mm thick, the other 3.36 mm ID 0.7 mm thick. The mass flow rate ranged from 200 to $500\;ks/m^2{\cdot}s$ and heating capacity were form 1.0 to 2.4 kW. The flow patterns of R-22 and R-410A were observed with a high speed camera through the sight-glass. The tests revealed that HTC of R-410A was higher than that of R-22 by maximum 5%. Annular pattern was observed for the most cases but stratified flow was also detected when x<0.2. The pressure drop in 3.36 mm ID pipe was higher than that of 5.35 mm by $30{\sim}50%$. Comparing with previous correlations such as Shah, Fujii and Soliman's, Fujii' showed the best good agreement with my data with a maximum deviation of 40%.

  • PDF

A Study on the Application of Composites to Pipe Support Clamps for the Light-weight LNGC (LNGC 경량화를 위한 파이프 지지용 클램프의 복합소재 적용 연구)

  • Bae, Kyong-Min;Yim, Yoon-Ji;Yoon, Sung-Won;Ha, Jong-Rok;Cho, Je-Hyoung
    • Composites Research
    • /
    • v.34 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • In the shipbuilding and marine industry, as a technology for reducing the weight of parts to reduce energy and improve operational efficiency of ships is required, a method of applying fibers-reinforced composites which is high-strength lightweight materials, as part materials can be considered. In this study, the possibility of applying fibers-reinforced composites to the pipe support clamps was evaluated to reduce the weight of LNGC. The fibers-reinforced composites were manufactured using carbon fibers and glass fibers as reinforcing fibers. Through the computer simulation program, the properties of the reinforcing materials and the matrix materials of the composites were inversely calculated, and the performance prediction was performed according to the change in the properties of each fiber lamination pattern. In addition, the structural analysis of the clamps according to the thickness of the composites was performed through the finite element analysis program. As a result of the study, it was confirmed that attention is needed in selecting the thickness when applying the fibers-reinforced composites of the clamp for weight reduction. It is considered that it will be easy to change the shape of the structure and change the structure for weight reduction in future supplementary design.

Physical Properties of High Performance Multilayered PVC Pipe (고성능 다층 PVC pipe의 물성)

  • Shin, Yong-Jin;Ryang, Kyung-Seung;Kim, Sung-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.711-717
    • /
    • 1999
  • A multilayer-structure material containing ductile and brittle layer simultaneously was examined and compared with a single layer material using fracture mechanical properties. We found that impact strength of multilayer structure material was considerably higher than single layer's and toughness was enhanced by about two times or higher in similar glass transition temperature($T_g$) region and the same dimension. The superposition principle of impact pulse was used for interpretation of kinetic stress wave as a high-velocity crack proceeds in the plastic. It was understood that the optimum condition of ductile/brittle thickness ratio could be designed in the final toughness enhancement of multilayer.

  • PDF

Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current (펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술)

  • Park, Duck-Gun;Babu, M.K.;Lee, Duk-Hyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

Present Condition of Indoor Noise Level in One-Room Type Multi-Family Housings around Campus (대학주변 원룸형 다가구주택의 실내소음수준 실태)

  • Choi Yoon-Jung
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.3 s.50
    • /
    • pp.191-198
    • /
    • 2005
  • The present study is a preliminary research improving the dwelling quality of one-room type multi-family housings around the university campus. The purpose of the study is to investigate the present condition of Indoor noise level using · residents' responses and field measurements. The respondents are 104 residents living in one-room type multi-family housings. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the $26th\~28th$ of November 2002. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of indoor noise. 2) They answer 'living equipment foise' and 'water hammer' as major types of indoor noise of house unit. 3) Outdoor noise levels, basic factor of noise environment in 6 subject buildings were distributed $52.8\~65.3dB(A)Leq_{5min}$ and were inappropriate to the standard for environmental noise, $55 dB(A)Leq_{5min}$. 4) Indoor noise levels of subject house units were measured as $27.5\~63.5dB(A)Leq_{5min}$, the average of each house unit except one house unit was higher than the level feeling as noise, 40dB(A). 5) It was found that the differences of indoor noise levels between subject house units were caused by 'residents' living noise', 'living equipment noise', 'water hammer', and 'walking and talking noise in stairs and corridors'. 6) Therefore, it is required to plan for improving the quality of noise environment in one-room type multi-family housing around the campus. For example, soundproof construction (including double window with pair glass and balcony), outdoor garden with trees and water for increasing natural sound, interior materials with sound absorbing power to absorb living noise, soundproof pipe or double surface pipe for decreasing 'water hammer', and noiseproof floors, etc. are required.

UV-Curing System for the Filament Winding of Large Diameter Pipe (대구경 파이프용 필라멘트 와인딩을 위한 UV 경화시스템)

  • Choi, Jae-Wan;Kim, Se-Il;Chung, Yong-Chan;Chun, Byaung-Chul
    • Clean Technology
    • /
    • v.16 no.4
    • /
    • pp.245-253
    • /
    • 2010
  • Optimum conditions for UV-radiated photopolymerization of unsaturated polyester that could be used as protecting layer of large diameter pipe were investigated in this paper. UV photopolymerization method was selected to solve the problems, arising when thermal polymerization by organic peroxide was used, such as the instability of peroxide initiator, the evolution of volatile organic compound, and thermal deformation of product. Two of the photo-initiators (Irgacure 819 and Darocure 1173) well known for its penetrating ability deep into the polymer layer were selected, and the optimum conditions for photopolymerization (1.5 phr initiator content, 1:1.2 initiator ratio, Ga lamp for UV source) were found from the thermal and mechanical test results of the resultant UP polymers. In addition, composite materials containing UP polymer and glass fiber were tested for hardness, impact strength, and flexural strength to find that the impact strength of composite significantly improved.

Development of Structural Model and Analysis of Design Factors for Small Greenhouse of Urban Agriculture (도시농업을 위한 소형온실 설계요인 분석 및 구조모델 개발)

  • Kim, Hyung-Kweon;Ryou, Young-Sun;Kim, Young-Hwa;Lee, Tae-Seok;Oh, Sung-Sik;Lee, Won-Suk;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.388-395
    • /
    • 2019
  • The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.