• 제목/요약/키워드: glass pipe

검색결과 104건 처리시간 0.021초

자동차 엔진 화재용 자동 소화 시스템 개발에 관한 연구 (A Study On The Development Of An Automatic Fire Extinguishing System For The Engine Compartment Use Of Automobiles)

  • 임성묵;정기창;김홍;강영구;이창섭
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1996년도 학술발표회
    • /
    • pp.57-61
    • /
    • 1996
  • Our goal was to make a cost-effective automatic fire extinguishing system for the engine compartment use of automobiles. We designed this system for the engine compartment. This system consists of 1)foam extinguisher, 2)four nozzles, 3)a pipe arrangement, and 4)an extinguishing device which is equipped with a glass bulb as detector. First and foremost, the extinguishing device was carefully designed to keep the system cost to a minimum. Second, a AFFF foam extinguisher was used because no other fire-fighting agents proved effective against fire in the engine compartment. The AFFF(Aqueous Film Forming Foam) agent which was used in the extinguisher is the 3M company's Light Water. We sought, however, to make other foams by using Halon 1301 and Halon alternatives such as HCFC Blend A, HFC-227ea. We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ration of the AFFF agent up to 44:1. We then demonstrated that our automatic fire extinguishing system is the most effective and lowest cost-system yet devised for passenger cars.

  • PDF

원전 금속단열재의 구조 건전성 강화를 위한 설계 방안 (Design for Strengthening Structural Integrity of the Reflective Metal Insulation in the Nuclear Power Plant)

  • 이성명;어민훈;김승현;장계환
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.107-113
    • /
    • 2015
  • The goal of this paper is to investigate structural integrity factors of RMI(reflective metal insulation) to confirm the design requirements in nuclear power plant. Currently, a glass wool insulation is using now, but it will gradually be replaced with the reflective metal insulation maded by stainless steel plates. The main function of an insulation is to minimize a heat loss of vessel and pipes in RCS(reactor coolant system). It has to maintain structural a integrity in nuclear power plant life duration. In this study, the structural integrity analysis was carried out both multi-plate and outer shell plate by using a static analysis and experimental test. First, inner multi-plate has a self support structure for being air space. Because the effect of total static weight in multi-layer plate is low, a plate collapse possibility is not high. Considering optimum thin plate pressing process, it has to pre-check the basic physical properties. Second, the outer segment thickness and stiffener shape are verified by the numerical static analysis, and sample test for both type of panel and cylindrical pipe model.

SUS 304 마이크로 와이어 직선화 처리에 관한 연구 (Study on Micro Wire Straightening Process in SUS 304)

  • 신홍규;김남수;김웅겸;홍남표;김병희;김헌영
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.17-22
    • /
    • 2004
  • In the study, we have developed a straightening system for 304 micro wires that are normally used in the medical and semi-conductor fields. To apply heat to the micro wires, we introduced the direct wire heating method which generates the thermal energy by the electrical resistance of the wire itself. To avoid the deterioration of the wire surface by the environment, such as the oxidation or the hydration, the $N_2$ gas was filled in the glass pipe in which the straightening process was being performed. A precision tension meter was also attached to control the tension of the wire during the heating and straightening process. In order to control the straightening process, several experimental investigations with varying the tension, the feeding velocity and the temperature (current) was carried out. As a result of experiments, we obtained the optimal processing conditions satisfying the straightness requirement of the micro wires.

  • PDF

원형튜브내에서 이동중인 고체입자층의 열전달 특성연구 (Heat Transfer to a Downward Moving Solid Particle Bed Through a Circular Tube)

  • 이금배;박상일
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1551-1558
    • /
    • 1994
  • An experiment was conducted to investigate whether an equation of heat transfer coefficient derived form energy equation of two-phase plug flow can be actually applied to the industrial field. The heat is constantly transfered to the sand beds from the wall of heat exchanger while the sand moves down through cylindrical heat exchanger by gravity from feed hooper. To increase heat transfer, turbulators such as glass ball and steel pipe packings were used. In addition, the experiment in the case of fluidizing the sand beds was also carried out. The temperatures of the sand beds and the wall were measured along the heat exchanger axis. The density and porosity of the sand beds were also measured. The deviations of the mean velocity of sands from the velocity on the wall surface because of the slip conditions on the wall were negligible (within 3%). The heat transfer coefficients when the turbulators were used and when the sand beds were fluidized were found to be much greater than those of the plain plug flow.

2사이클 기관 흡기 포오트의 가스 유동 특성에 관한 연구 (A study on the characteristics of gas flow in inlet port of 2 cycle engine)

  • 이창식
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.725-730
    • /
    • 1987
  • 본 연구에서는 2사이클 기관의 흡입 포오트 부근의 가스 유동을 레이저 도플 러 유속계를 이용하여 측정하고 가스의 평균 속도, 속도 변동, 유속 벡터 등을 기관의 회전 속도, 실린더 헤드의 모양 및 실린더로의 흡입 속도 측정점의 위치 변화에 대하 여 비교 검토하고, 유동 특성을 고찰하였다.

Detection of Corrosion and Wall Thinning in Carbon Steel Pipe Covered With Insulation Using Pulsed Eddy Current

  • Park, Duck-Gun;Kishore, M.B.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.57-60
    • /
    • 2016
  • Non Destructive Testing (NDT) methods that are capable of detecting the wall thinning and defects through insulation and cladding sheets are necessary. In this study we developed a Pulsed Eddy Current (PEC) system to detect wall thinning of ferro magnetic steel pipes covered with 95 mm thick fiber glass thermal insulator and shielded with aluminum plate of thickness 0.4 mm. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and a search coil sensor were used as a detecting element. In both the cases, the experimental data indicates a considerable change in the detected pulse corresponding to the change in sample thickness. The thickness of the tube was made to change such as 2.5 mm, 5 mm and 8 mm from the inner surface to simulate wall thinning. Fast Fourier Transform (FFT) was calculated using window approach and the results were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra.

유리섬유 배관/덕트 조인트 접합 로봇의 주행 및 공정을 위한 색상 실선의 영상처리 (Image Processing Method using Color Lines on Overlay Robot for Glass Fiber Pipe/Duct Joint)

  • 백종환;정명수;장민우;홍성호;서갑호;서진호;이기수;이재열
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2019년도 추계학술발표대회
    • /
    • pp.1090-1093
    • /
    • 2019
  • 유리섬유강화복합재료로 제작된 배관/덕트 조인트의 오버레이 자동접합을 할 수 있는 로봇이 개발되고 있으며 로봇의 구성 중 하나인 자동적층장치의 작업 시작 위치와 제자리 회전 오차를 극복할 수 있는 기준선에 대한 실시간 영상처리가 필요하다. 기존의 선 검출 알고리즘들은 연산량이 많아 실시간 처리가 어렵거나 전체 영상에서 잡음에 취약한 단점이 있다. 본 논문은 이러한 FRP 배관 및 덕트 내 색상 실선 인식 알고리즘의 효율적인 실시간 영상처리 방법에 관하여 소개하고 배관 내 라인 제어를 위한 선의 실제 거리를 계산하고 출력하는 방법을 나타내었다.

단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구 (A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials)

  • 정영인;최상민
    • 품질경영학회지
    • /
    • 제47권3호
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

기업 관리직의 젠더 격차와 "유리천장" 분석 (An Analysis of the Managerial Level's Gender Gap and "Glass Ceiling" of the Corporation)

  • 조혜원;함인희
    • 한국사회정책
    • /
    • 제23권2호
    • /
    • pp.49-81
    • /
    • 2016
  • 본 논문은 현재 기업의 관리직 내 젠더 격차 및 유리천장 현황을 점검해보고, 향후 여성고용의 질적 수준을 제고하기 위한 개선 방안을 모색하는데 목적이 있다. 이를 위해 조직 내 여성 구성원의 양적 증대가 갖는 의미를 중점적으로 다룬 선행 논의들을 정리해보고, 여성가족부에서 수행한 '여성인력패널조사' 3차년도(2010년 시행) 데이터를 활용하여 기업 내 관리직급의 젠더 격차 현황과 더불어 여성이 직면하고 있는 "유리천장"의 실재를 다각도로 검증해보았다. 그 결과 관리직 내 젠더격차가 공고하게 유지되고 있는 동시에, 특별히 유리천장은 '보다 상위직급으로 승진할 때 강화되는 현상'이 아니라 경력초기단계에 이미 존재하고 있음이 확인되었다. 이로부터 추출해낸 정책적 시사점은 다음과 같다. 첫째, 여성관리자의 경우 과장직급 이후부터 파이프라인의 단절현상이 발견된 바, 향후 상위직 승진을 위한 인력풀의 안정적 확보가 필수적이다. 둘째 유리천장이 경력단계 매우 초기부터 시작되는 것으로 나타난 바 이를 극복하기 위한 현실적 방안으로서, 출산 및 육아휴직 후 복귀 프로그램 지원, 경력개발 및 리더십 개발 프로그램의 제도화, 여성 관리자 간 네트워킹 및 멘토링, 외국계 기업의 성공 사례 도입 등 보다 구체적 노력이 시급히 요망된다. 셋째, 정부차원에서 여성고용율과 여성관리자비율을 모니터링 하는 적극적고용개선조치 기준은 여전히 소극적으로 설정된 바, 선진국 수준으로 가기 위한 궁극적 목표지점(stretching goal)을 세운 후 단계적으로 관리할 필요성이 제기된다. 넷째 여성고용과 관련해서 양적 지표관리에만 치중하기보다는, 제도와 프로세스 및 조직문화에 대한 점검, 여성 개인의 경험 및 체감 지표의 개발 등 질적 요소와 더불어 여성고용정책 내실화 및 질적 제고, 장기적 관점에서의 정책 체계화 등이 그 어느 때 보다 필요하리라 생각된다.

태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구 (A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy)

  • 윤준규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.324-331
    • /
    • 2013
  • 이중진공관형 집열기는 진공기술을 이용하여 흡수면에서 대류열손실을 줄일 수 있으며, 비교적 적은 온도차에서도 열수송능력과 열응답성이 빠른 이점이 있어 유용한 기기로 연구가 지속적으로 진행되고 있다. 본 연구에서는 태양열 집열기와 냉동기가 조합한 성능실험장치를 이용하여 태양열의 일사량, 유체온도의 제어조건에 따른 집열기의 동적 열성능을 파악하고, 이에 따른 항온조를 이용한 유체의 일정한 온도범위에서 냉동성능을 동시에 측정하여 열역학적 특성을 고찰하였다. 그 결과로서 집열효율의 관계식을 도출하였으며, 항온조의 출구온도 $18^{\circ}C$$22^{\circ}C$에서 집열기의 출구온도 $25^{\circ}C$로 설정하였을 때 항온조의 출구온도 $22^{\circ}C$ 경우가 외기온도 및 일사량이 증가함으로써 빠른 열전달특성을 보여 평균집열효율이 상승됨을 보였다. 또한 항온조의 출구온도 $18^{\circ}C$에서 냉동기의 성능계수는 6.2~7.1 정도의 결과를 얻게 되었다.