• 제목/요약/키워드: glass fiber filter

검색결과 63건 처리시간 0.029초

원소분석기를 사용한 부유입자상물질중의 탄소성분 분석시 포집여지의 특성에 관한 연구 (The Study on Characteristics of Collected Filter as Analysis of Carbon in Airborne Particulate Matters by Elemental Analyzer)

  • 황경철;조기철;최종욱
    • 환경위생공학
    • /
    • 제10권2호
    • /
    • pp.67-73
    • /
    • 1995
  • In order to study of characteristics of collected filter as analysis of carbon in airborne particulate matters by Elemental Analyzer, quartz fiber filter and glass fiber filter were used. The results are followed as; There was no difference of confidence in collection rate of airborne particulate matters between quartz fiber filter and glass fiber filter. Airborne particulate matters were collected on both filters evenly and the use of quartz fiber filter is better than glass fiber filter as analysis of carbon by thermal method.

  • PDF

카본블랙류 미세입자 포집을 위한 유리섬유 필터백의 고분자 표면처리에 관한 연구 (A study on the Polymer surface treatment of GF-filter bag for collection of fine Particle like carbon black)

  • 이봉;최희락;문창권
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.55-59
    • /
    • 2008
  • In this paper, we have investigated on collection efficiency of fine particle of glass fiber-filter bag according to the surface treatment. The solution consisted of polytetrafluoroethylene(teflon), graphite powder, silicon resin and water was used as a basic surface treatment agent. Tensile strength of glass filter-bag increased with up to 3hrs and then decreased with surface treatment time. Tensile strength and initial modulus of the glass fiber-filter bag treated by iodine after basic surface treatment for 3hrs were lower than those of basic surface treatment for 3hrs, however collection efficiency and fracture strain were higher than those of basic surface treatment for 3hrs. Glass fiber-filter bag with lower initial modulus and more strain will be extend the durable period and the one treated by iodine after basic surface treatment 3or 3hrs is expected high collection efficiency of fine particle. This method makes it possible to manufacture glass fiber-filter bag of the optimum condition.

  • PDF

대기중의 중금속 분석을 위한 여지의 전처리 방법에 관한 연구 (The Study on Pre-treatment Method of Filter for Analysing the Heavy Metals in Air Quality)

  • 김광래;이상칠;어수미;김민영;신재영;이재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.16-19
    • /
    • 2002
  • This study was carried out to establish the standardized analysis method in order to decide accurate concentrations of hazardous metals in the air. Acid decomposition method used usually was compared to microwave digestion method. Comparing results of tested background concentration in blank filter, we found that the magnitude of element concentration was Na, Ca, K, Mg, Al and Ba by order. The element concentrations of Glass fiber filter were higher than those of Quartz fiber filter, and the number of undetected components in Glass fiber filter was lower than that in Quartz fiber filter. Thus it is supposed that the concentration of background elements in Glass fiber filter was higher than those in Quartz fiber filter The extraction rate of microwave digestion method was superior to those of acid decomposition method during the test of blank filter as well as SRM of NIST. In case of the SRM of NIST, the average extraction efficiency of acid decomposition Method and microwave pretreatment is 53.8∼82.7%, 81.3∼97.1%, respectively. This result might be caused by the closed system of Microwave, which make outflow and loss of components less. Also microwave digestion method has other merits such as the minimization of time, reagents, and contamination. Furthermore, if the extraction condition, extraction time and used acids are optimized, the better results will be represented.

  • PDF

코크스제조공정에서 탄화시간과 시료채취방법에 따른 다핵방향족탄화수소 발생에 관한 연구 (A Study on Polynuclear Aromatic Hydrocarbons Emitted by Coking Time and Sampling Method in a Coke Oven Plant)

  • 윤충식;백남원
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.37-53
    • /
    • 1993
  • The polynuclear hydrocarbons (PAHs) emitted from coke oven standpipe were sampled using three sampling systems, including glass fiber filter+silver membrane filter, glass fiber filter+silver membrane filter+XAD-2 adsorbent tube, PTFE membrane filter+XAD-2 adsorbent tube, extracted by methylene chloride and analysed by gas chromathography using flame ionization detector. The results of this study were as follows. 1. Because the amounts of coke oven emissions(COE) were large, the analyses of PAHs were simple and possible without evaporation and concentration. Although the generation of COE was high during early stage of coking, the airborne concentration of PAHs was low and increased during late coking. 2. The contents of PAHs in COE were 1.35-2.81%. 3. The index components of PAHs were fluoranthene and pyrene. Their correlation coefficient to total PAHs were 0.96, 0.95, respectively. 4. The particulate PAHs were sampled by filter and gaseous PAHs by adsorbent tube. The collection efficiency of glass fiber filter+silver membrane filter was 20% of total amount sampled by filters+adsorbent and PTFE membrane filter 50%. Adsorbent tube must be attached to the filter to collect light and small PAH components. 5. The generation of acenaphthene and indeno (1,2,3-cd) pyrene were low and concentrations of fluorene and anthracene were $20-40ug/m^3$ throughout coking time. Other PAH eoncentrations were sometimes high. The generation of PAHs was low at 4-6 hours of coking time. The gaseous PAHs were generated earlier than particulate PAHs.

  • PDF

Purification of Water Contaminants Using Activated Carbon Fiber Filter with Phenolic Resin Coated on Glass Fibers as a Precursor

  • Baek, Il-Hyun
    • Carbon letters
    • /
    • 제1권2호
    • /
    • pp.82-86
    • /
    • 2000
  • The present research was undertaken to evaluate the possibility of water purification filter with activated carbon fibers (ACFs) using a very low cost precursor consisting of phenolic resin coated on glass fibers. The simplified procedure involving coating, curing and activation and a very low cost glass fiber as a raw material were adopted in order to reduce manufacturing cost. The breakthrough curves of the manufactured ACFs and the commercial activated carbon (AC, Calgon F-200) were investigated in the initial concentration range from 19 to 49 ppm for benzene, toluene and ethylbenzene. From breakthrough profiles, the manufactured ACFs had significantly faster adsorption kinetics than the AC. Especially the benzene breakthrough curves, the manufactured ACF (13 g of ACF with 32% of carbon on the glass) was over the limited level (5 ppb) after flowing of 32 l at initial concentration of 15 ppm, while the commercial AC was shown about 3 ppm in initial adsorption.

  • PDF

농작업자의 Kresoxim-methyl과 fenthion에 대한 호흡노출량 측정을 위한 IOM 채집기의 효율성 평가 (Evaluation for Application of IOM Sampler for Agricultural Farmer's Inhalation Exposure to Kresoxim-methyl and Fenthion)

  • 이지호;김은혜;이종화;신용호;;최훈;문준관;이혜리;김정한
    • 농약과학회지
    • /
    • 제19권3호
    • /
    • pp.230-240
    • /
    • 2015
  • 본 연구는 농작업자의 호흡노출 측정에 사용되어오던 고체흡착제 외에 최근에 사용되는 유리섬유여과지가 장착된 IOM 채집기에 대해서, 고체 제제인 kresoxim-methyl 입상수화제와 액상 제제인 fenthion 유제를 이용하여 포집효율과 파과율을 측정하여 효율성을 검증하고자 하였다. LC-MS/MS 기기상 최소검출량은 12.5 pg, 분석법상 검출한계는 5.0 ng/mL이었고, 각 노출 시료의 matrix matched standard의 직선성은 $R^2$ 값이 0.999 이상이었다. 사용된 유리섬유여과지와 고체흡착제에서의 두 가지 농약의 회수율은 유리섬유여과지는 kresoxim-methyl 102-109%, fenthion 97-104%, XAD-2 resin 고체흡착제는 각각 94-98%, 93-100%이었다. 포집효율은 IOM 채집기(유리섬유여과지 장착)와 고체흡착제(XAD-2 resin)를 연결한 후 개인용 공기펌프에 연결하여 측정하였다. 고체 및 액상 2가지 제제를 표준배율로 희석하여 IOM 채집기에 분무하여 포집효율을 본 결과 두 제제 모두 유리섬유여과지에 포집되었고 고체흡착제로 통과되지 않았다. 파과시험은 IOM 채집기의 유리섬유여과지에 농약 표준 용액을 가하고 고체흡착제를 연결한 후 개인용 공기펌프에 연결하여 측정하였다. 파과시험 결과, kresoxim-methyl은 87-101%, fenthion은 96-105%가 첫번째 유리섬유여과지에 흡착/보유되어 있었고 두 번째 유리섬유여과지나 고체흡착제로 파과되지 않았다. 따라서 유리섬유여과지가 장착된 IOM 채집기는 고체 제제나 액상 제제나 상관없이 포집효율과 흡착/보유 능력이 뛰어난 것으로 검증되어 농약 호흡노출 연구에 적극 활용될 것으로 판단한다.

양전하가 부가된 수처리 필터의 입자제거특성에 관한 연구 (A Study on the Positively Charged Filter for Removing Fine Particles in Water)

  • 정성학;김종원;김상희;전병헌;이승갑;이재근;안영철
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.454-460
    • /
    • 2012
  • The purpose of the present work is to investigate the removal characteristics of positively charged filters for capturing negatively charged particles such as bacteria and virus in water. In order to reduce the pressure drop and increase the filtration efficiency, the filter media, modified by charge modifier having positive functional groups, is developed and evaluated. Improved liquid filters have been developed with the modified surface charge to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in an aqueous liquid. The positively charged filter media is composed of glass fiber, cellulose and poly-ethylenimine resin for positively charging with the variation of volume ratio. The zeta potential value of the positively charged filter is +37.92 mV at the glass fiber and cellulose content ratio of 50 : 50 with resin content of 100%, while that of the PSL test particle is -23.5 mV at pH 7. The removal efficiency of the electro-positively charged filter is 98% for PSL particles of 0.11 ${\mu}m$, while that of the negatively charged filter is 7%. The positively charged filter media showed the potential to be an effective method for removing fine particles from the contaminated water for liquid filtration.

좁쌀약주의 여과공정 개선에 관한 연구 (Improvment on the filtration process of foxtail millet Yakju)

  • 강영주;고정삼
    • 한국식품저장유통학회지
    • /
    • 제10권4호
    • /
    • pp.482-487
    • /
    • 2003
  • 제주 지역의 대표적인 좁쌀 약주 제품에 대하여 유통 과정 중에 발생하는 침전 형성을 방지하기 위하여 여과 공정에 관한 연구를 실시하고 개선 방안을 제시하였다. 여러 공극 크기의 유리 막 여과지와 중공 사막 카트리지여과 매질을 가지고 좁쌀 약주를 여과한 결과, 대부분이 침전 형성 가능한 입자들은 1.2$\mu\textrm{m}$ 공극 크기의 여과 매질에 의한 여과로 제거 되는 것으로 조사되었다. 0.45$\mu\textrm{m}$ 중공 사막 카트리지인 경우 여과 flux는 342.8 lmh로 계산되었다. 여과에 따른 성분 변화는 크지 않은 것으로 조사되었다 그리고 4$^{\circ}C$와 실온을 48시간 씩 반복하면서 3개월간 저장 중 0.7$\mu\textrm{m}$ 공극 크기의 유리 막 여과지에 의한 여과에서도 미세한 침전 형성이 관찰되었다. 그러나 중공 사막인 경우에는 0.45$\mu\textrm{m}$에서도 침전 형성이 관찰되지 않았다. 따라서 완벽한 침전 형성 방지를 위해서는 현재 최종 여과 공정인 1 $\mu\textrm{m}$ 정밀 원통 여과지 공정 다음에 0.45$\mu\textrm{m}$ 중공 사막 여과 시스템도입이 효과적이다.

유리섬유 및 알루미늄 금속 혼합물 유리조성 개발 (Development on Glass Formulation for Aluminum Metal and Glass Fiber)

  • 조현제;김천우
    • 방사성폐기물학회지
    • /
    • 제10권4호
    • /
    • pp.247-254
    • /
    • 2012
  • 원전에서 발생되는 방사성폐기물에 대한 고화처리 방법 중 하나인 유리화기술이 일부 가연성폐기물에 대해 적용되고 있다. 국내외적으로 중저준위 방사성폐기물의 효과적인 감용과 안정적인 처분을 위해 다양한 폐기물에 대한 유리화기술 적용방안이 확대 연구되고 있으며, 최근에는 가연성폐기물 뿐만 아니라 알루미늄 금속과 같은 비가연성폐기물에도 유리화 연구가 활발하게 진행되고 있다. 공기조화계통 (HVAC)에는 주로 필터가 이용되고 있으며, 사용 후 필터는 여과재 (유리섬유 및 알루미늄)를 이용하여 배기체를 흡착하기 때문에 방사성폐기물로 처리가 되어야 한다. 본 연구는 필터에 대한 처리기술 연구를 위해 유도가열식 저온용융로 (Cold Crucible Induction Melter: CCIM)를 이용한 유리화 타당성 연구를 수행하였다. 사용후 필터에 대한 유리화 (Vitrification)는 먼저 유리섬유 및 알루미늄 함량을 고려한 최적의 유리조성을 개발 하였으며, 개발된 유리 조성을 이용하여 최적의 폐기물 저감을 위한 용융변수와 최종 생성된 유리고화체의 특성을 분석하였다. 사용후 필터 유리화용 조성유리는 주로 $SiO_2$$B_2O_3$로 구성되어 있다. 전기로를 이용한 용융물 특성시험에서는 폐기물 투입률 및 최종 생성물인 유리고화체의 특성이 검토되었다. 본 연구에서는 알루미늄 금속과 유리섬유로 구성된 필터에 대한 유리조성 개발과 이를 통해 생성된 유리고화체의 물리화학적 특성을 검토하고 유리화 타당성을 확인하였다.

정수 설비를 위한 양전하가 부가된 다공성 수처리 필터 개발과 성능평가 (Development and Performance Evaluation of Positively Charged Porous Filter media for Water Purification System)

  • 이창건;주호영;이재근;안영철;박성은
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.95-98
    • /
    • 2006
  • Filtration by fibrous filter is one of the Principle methods used for removing pollutant particles in the liquid. Because of the increasing need to protect both human health and valuable devices from exposure to fine particles, filtration has become more important. Filters have been developed with modified surface charge characteristics to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in water. The main purposes of this study are to develop and evaluate the performance evaluation of the apparatus for making a positively charged porous filter media and to analyze the surface characteristics of the filter media for capturing negavitely charged contaminants mainly bacteria and virus from water. The experimental apparatus consists of a mixing tank, a vacuum pumping system, a injection nozzle, a roller press and a controller. The filter media is composed of glass fiber(50-750 nm), cellulose($10-20{\mu}m$) and colloidal charge modifier. The characteristics of filter media is analyzed by SEM(Scanning Electron Microscopy), AFM(Atomic Force Microscopy) and quantified by measuring the zeta potential values.

  • PDF