• 제목/요약/키워드: glare evaluation

검색결과 45건 처리시간 0.017초

수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가 (Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting)

  • 정현지;김인태;최안섭
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.

대광원의 상하부 휘도차가 불쾌글레어 평가에 미치는 영향 (Effect of Luminance Difference on Discomfort Glare from a Large Glare Source with Non-uniform Luminance)

  • 김원우;김정태
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.29-34
    • /
    • 2007
  • Discomfort glare from windows is an important issue in window and daylighting design. This study aims to investigate the effect of luminance difference between the lower and the upper part of a large glare source. Experiments were conducted using a luminous body divided into two parts, the upper part and the lower part. The degree of discomfort glare from the luminous body was examined. The result shows that the part with lower luminance is perceived as a glare source when the part has higher luminance then the background luminance. The degree of discomfort glare was estimated for the experimental conditions, and compared to the observations. The estimation was made using two methods: one summed the glare sensation for each section, and the other used the average luminance of the whole luminous body. The result of the comparison shows that the method using the average luminance has approximate values to the observations. Consequently, the use of the average luminance was proposed for evaluation of discomfort glare from non-uniform large glare sources.

건축실내 인공조명의 불쾌글레어 평가를 위한 기초적 연구 (The Fundamental Research for Discomfort Glare Evaluation of Building Interior Artificial Illumination)

  • 이진숙;김원도;김병수
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.27-33
    • /
    • 2006
  • 건축 실내의 조명환경의 쾌적성을 평가하는 것은 주로 불쾌감을 유발하는 글레어의 정도를 인식하는 것이라 할 수 있다. 현재 국외에서 연구된 불쾌글레어를 평가하기 위한 실험식을 그대로 적용하기에는 글레어의 감각을 느끼는 정도가 인종에 따라 크게 다르게 나타나기 때문에 무리가 있다. 따라서 본 연구에서는 한국인의 시각적인 특성에 맞는 합리적인 불쾌글레어 평가를 위한 예측식을 작성하는 것을 최종목표로 하였으며 다음과 같이 4단계로 연구를 진행하였다. 첫째, 기존의 불쾌글레어 평가식에 대한 검토를 통해 실험변인들을 선정하였다. 둘째, 본 연구의 목적에 맞는 실험변인과 조건을 제어할 수 있는 실물대모형을 제작하였다. 셋째, 불쾌글레어 평가실험을 실시하였다. 최종적으로, 선행연구에서 서양인을 대상으로 제안된 UGR평가법과의 비교분석을 실시하였다. 연구의 결과를 요약하면, 1)불쾌글레어는 광원휘도, 배경휘도, 피험자와 시선의 위치 등에 크게 영향을 받는 것으로 나타났다. 2)실내 불쾌글레어 평가에서 광원과 피험자간의 거리보다 시야내에 글레어 광원이 위치하는 지의 여부가 더 중대한 영향을 미쳤다. 3)대표적인 불쾌글레어 평가시스템인 UGR과 비교 분석한 결과 다소 차이가 있는 것으로 나타났다. 이것은 한국인의 불쾌글레어감이 서양인과 차이가 있다는 것을 보여준다.

사무실 조명에서의 Discomfort Glare 계산법 적용 및 평가 (Evaluation of Discomfort Glare Indices in Office Lighting)

  • 허남돈;김훈
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.13-21
    • /
    • 2002
  • 실내공간에서 보편적으로 사용되는 조명방식으로 TAL 및 전반조명방식 등을 언급할 수 있는데, 일반적으로 우리나라 실내 조명환경에서는 전반조명방식을 채택하고 있다. 여기서, 가장 주요한 조명기술 요소가 바로 Glare이며, 특히 VDT를 사용하는 작업환경에서는 더욱 그러하다. 이러한 실내 조명환경에서의 Glare에 대한 연구 및 평가법은 CIE 및 IESNA 등에서 꾸준히 연구되어 제시되고 있으며, 각종 실내 조명환경에 따라 다르게 적용되고 있다. 한편, 국내의 실내 조명상황에 대해 Glare평가를 위한 G 분류가 제시되고 있지만, 평가에 있어 그 한계성이 있으며, 이 외에는 좀더 상세한 Glare 규정이 없는 실정이며, 각종 실내 조명환경에 적용하기가 어려운 게 사실이다. 본 논문에서는, 위에서 제시하고 있는 주요 Glare규정들을 가지고, 국내의 조명상황에 맞춰 실내 공간 및 조명기구 등을 각각 선정한 후, Glare 평가법들을 적용하였다. 또한 국내의 실내 조명환경에 적합한 Glare Index를 제시하고자, 평가법 상호간의 비교 및 적합성을 꾀하고자 하였으며, 더 나아가 국내에 맞는 Glare Index를 마련하고자 하였다.

창의 조망에 따른 분위기 및 시각적 쾌적성 평가에 대한 예비실험 (Preliminary Experiments on Discomfort Glare and Subjective Impressions from the Window Views)

  • 신주영;윤근영;김정태
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.25-30
    • /
    • 2010
  • The daylited space can improve visual comfort and occupant's well-being. However discomfort glare from the daylight is a common problem in indoor environments and in general, the window is the main glare sources. Some formulas have been proposed for predicting glare from the daylight, however, they do not consider the effect on glare of the view through a window and some studies proved that they are inadequate in real daylight situation. This research aims to identify the relationship between view and discomfort glare considering the subjective impressions. As a preliminary experiment, this paper sets up the experimental protocol to reveal relationships between views from a window and visual perception in a controlled laboratory experiment. $1.2m{\times}1.2m$ artificial window was developed and $0.9m{\times}0.9m$ view image was placed on the window. Discomfort glare and impression evaluation was carried out under four different views and one blank view as a reference condition. The results showed that the subjects evaluated discomfort glare differently with the views even under the same luminance conditions and tended to feel less glare with distance views compared to near views.

확산필름 부착 위치에 따른 광선반 성능개선 연구 (Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position)

  • 박은수;이행우;송석재;김용성
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.

건축실내 인공조명의 불쾌글레어 평가실험에 적용된 실험변수의 민감도 분석에 관한 연구 (Study on Sensitivity of Variables of the Experiment to Evaluate Discomfort Glare of Interior Artificial Illumination)

  • 이진숙;김원도;김창순
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-32
    • /
    • 2008
  • 본 연구에서는 한국인의 시각적 특성을 반영한 불쾌글레어의 합리적인 예측을 위해 국내에 실제적으로 적용 가능한 불쾌글레어 예측식을 작성하는 것이 최종목표로 하고 있으며, 본 논문에서는 주변의 일반적인 사무실 건물의 조명환경을 대상으로 기본 단위로 구획하여 실물대모형(Mock-up)을 제작하여 실험을 진행하고 글레어에 최대 영향요인인 광원휘도를 비롯한 배경휘도, 입체각, 광원면적, 루버종류와 불쾌글레어의 관계를 도출하는 것을 목적으로 하였다. 본 연구는 다음과 같이 4단계로 나누어 연구를 진행하였다. 첫째, 불쾌글레어 평가등급을 정의하고 분류하기 위하여 선행연구에서 사용된 평가등급을 조사하여 연구목적에 부합되도록 수정하여 실험에 적용할 수 있도록 하였다. 둘째, 기존 불쾌글레어 평가실험식에 대한 검토를 통해 실험변수, 변수범위, 평가대상, 평가내용 등을 선정하였다. 셋째, 연구의 목적에 부합되도록 실험변인을 조절할 수 있는 실물대모형(Mock-up)을 제작하여 불쾌글레어 평가실험을 실시하였다. 최종적으로 불쾌글레어감과 광원휘도, 루버종류, 광원면적, 피험자위치간의 관계분석을 통해 실험변수의 민감도를 분석하였다. 연구 결과 인공광원의 불쾌글레어감에 영향을 주는 주요 변수는 광원휘도, 루버의 유무, 광원면적, 피험자위치(입체각) 순으로 영향을 미치는 것으로 나타났다.

불균일한 휘도를 갖는 창면의 불쾌글레어 평가실험 (An Experiment of Discomfort Glare from Non-uniform Glare Source)

  • 신주영;김정태;김원우
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-9
    • /
    • 2009
  • 자연채광은 건물 재실자에게 시각적 편안함과 쾌적함을 제공하여 건강성을 향상시키며 조명 에너지를 절약할 수 있는 중요한 조명환경 요소이다. 자연광에 의해 발생되는 창면에서의 글레어는 장시간 노출될 시 시각의 저하, 시각적 불쾌감의 원인이 된다. 창면에 의한 불쾌글레어 평가시에는 창면에서 글레어 광원을 어떻게 선별할 것인가가 중요한 문제이다. 기존의 불쾌글레어 평가법을 적용하더라도 글레어 광원을 한정할 방법이 없다. 따라서 본 연구에서는 글레어 광원 선별방법을 모색하기 위하여 불균일한 대광원의 휘도차가 불쾌글레어감에 미치는 영향을 검토하였다. 이를 위하여 $120{\times}120[cm]$의 정사각형 모형창을 제작하였다. 실험변수는 균일과 불균일한 휘도분포의 광원의 휘도비와 광원크기로 선정하였다. 실험방법은 모형창을 3분할한 후, 각기 다른 휘도비를 설정하여, 1[m], 1.5[m], 3[m] 거리에서 불쾌글레어를 평가하도록 하였다. 실험 결과 두 개의 결론을 얻었다. 첫째, 광원의 평균휘도가 증가할수록 불쾌글레어 평가값이 증가하였으며, 둘째, 창면 상부의 천공 부분만을 글레어 광원으로 볼 수 없으며 하부면도 블쾌글레어 평가에 영향을 주는 것으로 나타났다. 본 연구의 결과는 채광창으로부터의 불쾌글레어 평가 시 글레어 광원을 선택하는 기준으로 활용될 수 있을 것이다.

시야내의 글레어감각 측정용 기기의 개발 (A Development of on Instrument for Measuring Glare Sensation in the Visual Field)

  • 박성률;김정태;김원우
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.9-17
    • /
    • 2009
  • 인공조명으로부터 유발되는 볼쾌글레어는 건강건축의 조명환경을 위한 중요한 평가요소이다. 글레어는 인간의 전체시야범위 내에서 휘도와 휘도대비에 의해 발생되는 감각으로서 정의되며, 시각적 작업을 수행하는 재실자에게 시작업의 방해를 일으켜 시각적 불쾌감을 유발할 수도 있다. 글레어는 글레어 광원의 위치, 글레어 광원의 밝기, 글레어 광원의 크기와 배경의 휘도에 의한 영향으로 평가될 수 있다. 따라서 변수를 제외한 나머지 요소들을 일정한 상태로 유지할 수 있는 실험기기가 글레어 평가를 위해 필요하다. 최근까지 글레어 평가기기의 성능한계로 인하여 글레어 요소들 간의 상관관계를 확인함에 있어서 제한이 있었다. 이에 선행연구를 참고하여 글레어 실험기기를 제작하고 이 기기를 글레어측정기기라고 명명하였다. 글레어측정기기는 지름 2[m] 반구형 스크린 내부 표면을 균일한 배경휘도 형성을 위해 흰색 무광택 도료로 마감하였으며, 광원들이 내부에 설치되어 있다. 글레어 광원은 $0{\sim}150,000[cd/m^2]$까지 조정이 가능하며 12개의 백열램프에 의한 배경휘도는 $0{\sim}350[cd/m^2]$까지 조정이 가능하다. 글레어 측정기기를 사용하여 피험자를 대상으로 시야범위 한계, 시선상의 BCD휘도와 상하부 시야에서의 BCD휘도 측정에 대한 연구가 진행되었다.