• Title/Summary/Keyword: glare

Search Result 209, Processing Time 0.022 seconds

Assessment of The Luminance Distribution from Daylighting window by Using Image Processing Methodology (이미지 프로세싱 기법을 활용한 채광창의 휘도분포 평가)

  • Park, Jong Myung;Lim, Hong Soo;Kim, Jeong Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.5
    • /
    • pp.77-84
    • /
    • 2012
  • Daylighting is the controlled admission of natural light into a space, reducing electric lighting and saving energy. By providing a direct link to the dynamic and perpetually evolving patterns of outdoor illumination, daylighting helps create a visually stimulating and comfort environment for building occupants, while reducing energy costs. Especially, however, glare is the most important factor in daylighting, which is issued by incoming direct sunlight into windows. This study analyzed the discomfort glare on a daylighting window by using Image processing methodology and found a solution to problems with glare source of occupants. There are several ways to evaluate discomfort glare such as UGR (Unified Glare Rating) of CIE, DGI (Daylight Glare Index, Hopkinson, 1972) and VCP (Visual Comfort Probability) of IES. These are used to apply to the relatively little artificial light source and they cannot cover discomfort glare from a real daylighting window. In this regarding, this paper aimed to calculate DGI index of the real daylighting window in a experimental space by using image processing methodology. The variables and outcomes are luminance distribution of non-shading window, effect of venetian blind installed on the window and locations related to position index of DGI.

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.

A Comparative Study on Discomfort Glare Sensation in Entire Visual Field for Position Index (포지션 인덱스 작성을 위한 상·하부 시야의 불쾌글레어감 비교)

  • Kim, Won-woo;Park, Sung-Ryul;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.37-43
    • /
    • 2007
  • Discomfort glare is an important factor influencing appraisal for lighting environment. Unified Glare Rating (UGR) which has been proposed by CIE is one of the formula for evaluating discomfort glare. Position index is an important factor in the UGR formula. Position index was proposed by Guth in 1949. It has been used until present limiting upper visual field. Lower visual field has different sensation of brightness in comparing with upper visual field. Therefore, it is necessary to propose position index about lower visual field. The objective of this study is to investigate the brightness sensation in upper and lower visual field. First, the visual field was measured on the self-made Glare Tester. Second, luminance of the Borderline between Comfort and Discomfort (BCD) was measured on the glare Tester. Circular sources of brightness were located at various angular distances from the line of vision along five meridians, $0^{\circ}$, $45{\circ}$, $90{\circ}$, $-45{\circ}$, $-90{\circ}$. The size of the glare source is 0.0011sr. The luminance of the surrounding field, which extended over the entire visual field, was maintained $34ccd/m^2$. Ten subjects aged from 25 to 29 were participated in the experiment. The results show that the luminance of BCD on the line of vision is $4337cd/m^2$ and the glare sensation of the lower visual field is more sensitive than the upper visual field.

The Fundamental Research for Discomfort Glare Evaluation of Building Interior Artificial Illumination (건축실내 인공조명의 불쾌글레어 평가를 위한 기초적 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.27-33
    • /
    • 2006
  • Evaluating comfort of illumination environment of building interior is recognizing the degree of glare causing discomfort. Currently, to use the experimental formula for discomfort glare studied abroad it would be not appropriate because each races feel about the degree of glare differently. Therefore, this study aim to make up prediction formula for evaluating discomfort glare reasonably from Koreans' vision and it proceeded with 4 stages as follows: First, after reviewing the existing discomfort glare evaluation formula, I selected experimental variables. Second, I made a mock-up that I can control experimental variables and conditions according to the purpose of this study. Third, 1 conducted discomfort glare evaluation experiment. Finally, compared with UGR evaluation method suggested for Westerner in prior studies. In conclusion, 1) it's proved that discomfort glare is influenced highly by a light source luminance, background luminance and location of testee and the line of vision. 2) In interior discomfort glare experiment whether the glare light source is placed within range of vision or not has more significant influence than the distance between the light source and testee. 3) I compared and analyzed with UGR, the most representative discomfort glare evaluation system and I found there is a little difference in the results. This shows discomfort glare of Koreans and Westerners are different.

Analysis of Discomfort Glare by Visitors' Eye-level and Illumination Angles in Museum (박물관의 조명 각도와 관람객 눈높이에 따른 불쾌적 현휘 분석)

  • Lee, Youngwoong;Kim, Sanghyun;Jo, Seongeun;Kang, Yujin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.4
    • /
    • pp.328-333
    • /
    • 2015
  • The museum is a important place to inform the value of various antiquities and relics. The museum, founded in domestic, were increased 90% in 2013 compared to 2006, and total number of including private museums were increased more than three times over the past decade. There are installing a variety of illumination and air-conditioning system, such as the spot lighting of exhibition explanation. But the exhibition explanation should not happen to visual perception disabilities by lighting. According to ICOM (International Council of Museum), it is stipulating that the museum should not to occur glare. However, we confirmed some occurred the glare and it was lack of previous studies about prevention plan. In this study, we verified occurrence of the glare by illumination angles and visitor's eye-level. The luminance values were determined by using DSLR camera and illuminometer. As a result, when illumination angle is 90 degree, the glare did not occurred by the luminance value ratio of over 0.167 regardless of eye-level. By contrast, the angle 30 degree was appeared glare with all level. And this study was compared luminance values that obtained through experiment and surveying.

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

Solar Module with a Glass Surface of AG (Anti-Glare) Structure (연요철(Anti-Glare) 구조의 표면 유리 기판을 가지는 고효율 태양전지 모듈)

  • Kong, Dae-Young;Kim, Dong-Hyun;Yun, Sung-Ho;Bae, Young-Ho;Yu, In-Sik;Cho, Chan-Seob;Lee, Jong-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.233-241
    • /
    • 2011
  • Currently, solar module is using the two methods such as a glass-filled method or a super-straight method. The common point of these methods is to use glass structure on the front of solar module. However, the reflectance of the solar module is high depending on the height of the incident sunlight due to the flat surface of the module front glass. Purposed to solve these problems, AG (anti-glare) structures were formed on the glass surface. Next is fabrication methods of AG structure. First, uneven structure made by micro blaster equipment was dipped in Hydro-fluidic acid (HF) acid. HF acid process was carried out to remove particles and to make high transmittance. The reflectance and transmittance of the anti-glare glass was compared to those of the bare glass. The reflectance of anti-glare glass decreased approximately 1% compared with bare glass. The transmittance of anti-glare glass was similar to bare glass. According to the sample angle, the difference of the reflectance between bare glass and the anti-glare glass was about 19%. Isc and efficiency value of anti-glare glass on bare solar cell appeared about 3.01 mA and 0.228% difference compared with bare glass. Anti-glare glass on textured solar cell appeared about 9.46 mA and 0.741% difference compared with bare glass. As a result, the role of anti-glare in the substrate is to reduces the loss of sunlight reflected from the surface. In this study, therefore, AG structure on the solar cell was used to improve the efficiency of solar cell.

Influences of Fiber Laminate Orientation on the Behavior of Fatigue Delamination in GLARE (GLARE 의 섬유층 배향이 피로층간분리 거동에 미치는 영향)

  • 황진우;송삼홍;김철웅
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.479-482
    • /
    • 2004
  • The behavior of fatigue delamination in a GLARE(Glass Fiber Reinforced Metal Laminates) under fatigue loading conditions investigated. The behavior of fatigue delamination was examined basing on investigation of the crack and delamination using a SAM (Scanning Acoustic Microscope). The crack and delamination behavior on the relationship among a-N, SAM images and crack length-delamination length were considered. The test results indicated the features of different fatigue delamination and crack growth according to each fiber orientation angle and also obtained to more increase delamination than crack through the relationship between crack length and delamination length in GLARE.

  • PDF

A Case Study on the Driver's Glare Hazard Assessment by Light Reflection of Curtain Wall Type Buildings (커튼월 고층 건물 빛 반사에 의한 운전자 눈부심 가능성)

  • Song, Hyung-Jun;Seo, Young Kyo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.26-31
    • /
    • 2021
  • Buildings with glass curtain walls have become popular due to their appealing aesthetics and ability to let in natural light. However, light reflection from the glass surface is unavoidable in these buildings. In particular, the reflection of light from the glass envelope can create afterimage glare, a hazard to nearby drivers and pedestrians. Despite this potential danger, glare from buildings with curtain walls has not been well-studied. Hence, we analyzed the effect of light reflection on glare around a glass-enclosed skyscraper, depending on its surface reflectance. We investigated the potential hazard of glare to drivers using a commercially available software program. The results indicate that the direction of light reflection is distinctive when the incident angle of solar light increases. Moreover, this light reflection is high enough to induce an afterimage to drivers and pedestrians near the building. We found that keeping the reflectance of the building surface under 3% is required to minimize the afterimage hazard to drivers. Consequently, we recommend managing glass reflectance and installing additional traffic safety systems to reduce traffic accidents near curtain wall buildings.

Analysis of Highway Hazardous Area by Sun Glare Intensity Using GIS Simulation (GIS Simulation을 이용한 태양광에 의한 교통사고 위험지역 분석)

  • Kim, Ho-Yong;Baik, Ho-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.4
    • /
    • pp.91-100
    • /
    • 2010
  • Existing traffic safety studies have focused on identifying the relationship among roadway crashes, highway design and incremental weather condition such as rainy/ice weather. However, it is hard to find researches that studied the effect of sun glare on traffic safety although there are abundant evidences demonstrating that fatal traffic crashes are attributed to the sun glare. Affecting drivers'vision particularly during the morning or the evening time when the sun positions close to the horizon, sun glare directly deteriorate drivers'judgmental capability. In this paper, we numerically analyze the effect of sun glare on the drivers'vision in time and space domains. Applied to the roadways around St Louis area in the United States, the GIS based simulation analysis identifies the time of day in a year and the segments of highways that are potentially influenced by the sun glare. This study evidentially confirms the fact that roadway bounded for West and East directions have longer time influenced by sun glare particularly during Spring and Fall season than other roadways. The computational result provides risky time periods of day at intersections or pedestrian crossings where the sun glare potentially endangers traffic safety, which be utilized to reduce the crashes due to the sun glare.