• 제목/요약/키워드: gingival thickness

검색결과 81건 처리시간 0.02초

Revisiting the measurement of keratinized gingiva: a cross-sectional study comparing an intraoral scanner with clinical parameters

  • Ahmet Mert Nalbantoglu;Deniz Yanik
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.362-375
    • /
    • 2023
  • Purpose: The aim of this study was to investigate the relationships between gingival thickness (GT) and keratinized gingiva width (KGW), papilla height (PH), and crown ratio (CR) by employing transgingival probing and an intraoral scanner (IOS). Methods: This cross-sectional study examined 360 maxillary anterior teeth from 60 patients. GT was assessed using transgingival probing with an endodontic spreader. KGW, CR, and PH were measured using an IOS. One-way analysis of variance, the Student's t-test, and Spearman correlation coefficients were employed for statistical analysis. Results: Higher GT was significantly associated with thinner KGW in the central region (P=0.019). There was no statistically significant difference in GT between teeth (P=0.06). PH was lower in lateral teeth than in canines (P=0.047), with a PH of 2.99 mm in lateral teeth. The KGW was narrower in canines than in central teeth (P=0.007). A moderate correlation was observed between KGW and PH in the central region (P=0.01), while a weak negative correlation was found between KGW and CR (P=0.043). Conclusions: A moderate negative correlation was found between GT and KGW, as well as between PH and KGW in central teeth. In contrast, a weak negative correlation existed between CR and KGW. The PH (2.99 mm) was lower in lateral teeth than in canines. The traditional paradigm, which suggests a positive correlation between KGW and GT, was reevaluated by measuring KGW using an IOS.

Dimensional change of the healed periosteum on surgically created defects

  • Cho, Eun-Hee;Park, Jung-Chul;Cha, Jae-Kook;Kim, Yong-Tae;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • 제41권4호
    • /
    • pp.176-184
    • /
    • 2011
  • Purpose: The final goal of regenerative periodontal therapy is to restore the structure and function of the periodontium destroyed or lost due to periodontitis. However, the role of periosteum in periodontal regeneration was relatively neglected while bone repair in the skeleton occurs as a result of a significant contribution from the periosteum. The aim of this study is to understand the histological characteristics of periosteum and compare the native periosteum with the repaired periosteum after elevating flap or after surgical intervention with flap elevation. Methods: Buccal and lingual mucoperiosteal flaps were reflected to surgically create critical-size, "box-type" (4 mm width, 5 mm depth), one-wall, intrabony defects at the distal aspect of the 2nd and the mesial aspect of the 4th mandibular premolars in the right and left jaw quadrants. Animals were sacrificed after 24 weeks. Results: The results from this study are as follows: 1) thickness of periosteum showed difference as follows (P<0.05): control group ($0.45{\pm}0.22$ mm)> flap-elevation group ($0.36{\pm}0.07$ mm)> defect formation group ($0.26{\pm}0.03$ mm), 2) thickness of gingival tissue showed difference as follows (P<0.05): defect formation group ($3.15{\pm}0.40$ mm)> flap-elevation group ($2.02{\pm}0.25$ mm) > control group ($1.88{\pm}0.27$ mm), 3) higher cellular activity was observed in defect formation group and flap-elevation groups than control group, 4) the number of blood vessles was higher in defect formation group than control group. Conclusions: In conclusion, prolonged operation with increased surgical trauma seems to decrease the thickness of repaired periosteum and increase the thickness of gingiva. More blood vessles and high cellular activity were observed in defect formation group.

유동성 레진의 두께가 미세누출에 미치는 영향 (THE EFFECT OF MARGINAL MICROLEAKGE ACCORDING TO THICKNESS OF FLOWBLE RESIN)

  • 송기강;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제30권5호
    • /
    • pp.363-371
    • /
    • 2005
  • 본 연구는 2급 복합레진 수복 시 다양한 두께의 유동성 레진 이장이 법랑질 또는 상아질 치은측 변연부의 미세누출에 미치는 영향을 평가하기 위하여 시행하였다. 발거된 상, 하악 대구치의 근심 또는 원심면에 2급 와동을 형성하고 혼성복합레진만으로 충전한 군 (대조군)과 유동성 레진을 치은측에 0.5 mm (실험 1군), 1 mm (실험 2군), 2 mm (실험 3군) 두께로 이장한 후 복합레진을 충전한 군으로 분류하였다. 각 군은 $5^{\circ}$$55^{\circ}C$에서 500회 열순환을 시행한 후 $2\%$ methylene blue에 24시간 동안 침적시켜 광학 입체현미경하에서 변연부의 색소 침투를 관찰하였다. 본 연구의 결과 유동성 레진의 다양한 두께는 복합레진 수복물의 변연부 미세누출에 영향을 미쳤다. 복합레진을 이용한 구치부 2급 와동 수복 시 법랑질 또는 상아질 변연에서 0.5 mm두께로 유동성 레진을 적용하는 것이 미세누출 감소에 효과적인 것으로 나타났다.

치아 순면 형태가 측색 기기를 이용한 치아 색상 측정 결과에 미치는 영향 (INFLUENCE OF THE LABIAL SURFACE IRREGULARITY ON THE MEASUREMENT OF THE TOOTH COLOR BY SPECTROMETER)

  • 최용진;박수정;조현구;황윤찬;오원만;박병주;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제32권5호
    • /
    • pp.411-418
    • /
    • 2007
  • 본 연구는 치아 순면의 굴곡 정도가 측색기를 이용한 치아 측색 결과에 어떠한 영향을 미치는지 확인하고자 시행하였다. 고른 치열을 가진 20대 성인 11명으로부터 채득한 인상에 A2색상의 임시 금관 제작용 레진 (Luxatemp Automix Plus, DMG, Germany)을 충전하여 치아 모형을 제작하고, 중절치, 측절치, 견치, 그리고 제1소구치의 절단부, 중앙부, 치경부의 색상을 1 mm 직경의 측정구를 가진 Specbos 2100 (JETI, Germany) spectrometer를 사용해 측정하고, 디스크 형태로 제작된 대조군과의 색차를 환산하여 다음의 결과를 얻었다. 모든 치아 모형에서 $L^*$값과 $b^*$값은 절단부에서 치경부로 갈수록 낮아지는 경향을 보이나 $a^*$값은 증가하는 경향을 보였다. 디스크 형태의 대조군과의 색차는 모든 치아의 절단부가 가장 큰 값을 보였으며, 치경부가 가장 작은 값을 보였으며, 견치가 다른 치아들에 비해 디스크 형태의 대조군과 작은 색차를 보인 반면, 중절치가 가장 큰 색차를 보였다 (p < 0.01). 이상의 결과는 본 실험에 적용한 optic-fiber를 통해 색을 측정하는 기기를 치아 측색에 적용하기 위해서는 먼저 일정한 측색 조건의 표준화와 치아와 접촉하는 측정부의 치아 표면의 굴곡을 극복할 수 있는 형태의 개발이 필요함을 시사한다.

약물함유 생체분해성 차폐막의 유도조직재생에 관한 연구 (Drug loaded biodegradable membranes for guided tissue regeneration)

  • 김동균;이승진;정종평
    • Journal of Periodontal and Implant Science
    • /
    • 제25권2호
    • /
    • pp.192-209
    • /
    • 1995
  • The purpose of this study was to evaluate drug-loaded biodegradable membranes for guided tissue regeneration(GTR). The membranes were made by coating mesh of polyglycolic acid(PGA) with polylactic acid(PLA) containing 10% flurbiprofen or tetracycline. The thickness of membrane was $150{\pm}30{\mu}m$, and the pore size of surface was about $8{\mu}m$ in diameter. The release of drugs from the membrane was measured in vitro. Cytotoxity test for the membrane was performed by gingival fibroblast cell culture, and the tissue response was observed after implant of membrane into the dorsal skin of the rat for 8 wks. Ability to guided tissue regeneration of membranes were tested by measuring new bone in the calvarial defects(5mm in diameter) of the rat for 5 weeks. The amount of flurbiprofen and tetracycline released from membrane were about 30-60% during 7 days. Minimal cytotoxity was observed in the membrane except 20% drug containing membrane. In histologic finding of rat dorsal skin, many inflammatory cells were observed around e-PTFE, polyglactin 910 and PLAPGA membrane after 1 or 2 weeks. PLA-PGA membrane was perforated by connective tissue after 4 or 6 weeks, and divided as a segment at 8 weeks. In bone regeneration guiding potential test, tetracycline loaded membrane was most effective (p

  • PDF

Periodontal granulation tissue preservation in surgical periodontal disease treatment: a pilot prospective cohort study

  • Rodriguez, Jose A. Moreno;Ruiz, Antonio J. Ortiz
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.298-311
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the clinical outcomes of periodontal granulation tissue preservation (PGTP) in access flap periodontal surgery. Methods: Twenty patients (stage III-IV periodontitis) with 42 deep periodontal pockets that did not resolve after non-surgical treatment were consecutively recruited. Access flap periodontal surgery was modified using PGTP. The clinical periodontal parameters were evaluated at 9 months. The differences in the amount of granulation tissue width (GTw) preserved were evaluated and the influence of smoking was analyzed. Results: GTw >1 mm was observed in 97.6% of interproximal defects, and the granulation tissue extended above the bone peak in 71.4% of defects. At 9 months, probing pocket depth reduction (4.33±1.43 mm) and clinical attachment gain (CAG; 4.10±1.75 mm) were statistically significant (P<0.001). The residual probing depth was 3.2±0.89 mm. When GTw extended above the interproximal bone peak (i.e., the interproximal supra-alveolar granulation tissue thickness [iSUPRA-GT] was greater than 0 mm), a significant CAG was recorded in the supra-alveolar component (1.67±1.32 mm, P<0.001). Interproximal gingival recession (iGR) was significant (P<0.05) only in smokers, with a reduction in the interdental papillary tissue height of 0.93±0.76 mm. In non-smokers, there was no increase in the iGR when the iSUPRA-GT was >0 mm. The clinical results in smokers were significantly worse. Conclusions: PGTP was used to modify access flap periodontal surgery by preserving affected tissues with the potential for recovery. The results show that preserving periodontal granulation tissue is an effective and conservative procedure in the surgical treatment of periodontal disease.

Lipomyces starkeyi KSM 22 glucanhydrolase의 추가가 구강세정액의 치태 억제 효과에 미치는 영향 (Effect of mouthrinse containing Lipomyces starkeyi KSM 22 glucanhydrolase on plaque formation during a 4-day period)

  • 서은주;정현주;김옥수;김영준;김상혁
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.195-204
    • /
    • 2004
  • A novel glucanhydrolase from Lipomyces starkeyi KSM 22 has been suggested as a promising anti-plaque agent because it has been shown to have additional amylase activity and mutanase activity besides dextranase activity and to strongly bind to hydroxyapatite. Mouthrinsing with Lipomyces starkeyi KSM 22 glucanhydrolase solution was comparable to 0.12% chlorhexidine mouthwash in inhibition of plaque accumulation and gingival inflammation and local side effects were less frequent and less intense in human experimental gingivitis. In this study, Lipomyces starkeyi KSM 22 glucanhydrolase mouthrinses (1 and 2 unit/ml) were compared with a control mouthrinse (commercial 0.01% benzethonium chloride mouthrinse, $Caregargle^{(R)}$, Hanmi Pharmaceuticals) in the ability to inhibit plaque formation. A 3-replicate clinical trial using 4-day plaque regrowth model was used. Fifteen volunteers were rendered plaque-free on the 1st day of each study period, ceased toothcleansing, and rinsed 2X daily with allocated mouthrinse thereafter. On day 5, plaque accumulation was scored and the washout periods was 9 days for the next trial. Lipomyces starkeyi KSM22 glucanhydrolase(1 unit and 2 unit)- containing mouthrinse resulted in Significantly lower plaque formation in plaque area and thickness, compared to the control mouthrinse. There was no significant difference in plaque inhibition between enzyme-mouthrinses at 2 different concentrations used. This glucanhydrolase- containing mouthwash resulted in significantly lower plaque area severity index score and tended to have lower plaque thickness severity index score than those of control mouthrinse. But there was no significant difference according to the enzyme concentration. From these results, Lipomyces starkeyi KSM 22 glucanhydrolase-containing benzethonium chloride mouthrinse has greater anti-plaque effect than the commercial mouthrinse alone. Therefore this glucanhydrolase preparation is a promising agent for new mouthwash formulation in the near future.

금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구 (A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN)

  • 윤종욱;양재호;장익태;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

Embossed new dental pick이 치주염에 미치는 영향 (Effect of embossed new dental pick on periodontitis)

  • 석헌주;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.563-572
    • /
    • 2004
  • Since bacterial plaque is known as the major cause of every oral disease, it is necessary to control plaque to maintain periodontal health. Although tooth brushing has been the typical method of plaque control, additional use of plaque control devices are necessary for cleansing interdental areas. Dental floss has been used for a long time as the additional plaque control device and proved to be effective. The newly developed embossed new dental pick is composed of elastic plastic material in form with its tip longer than other toothpick. In addition, as thickness of the tip gradually increases, it can be adapted easily with minimal trauma to interdental gingiva. The embossed tip can remove dental plaque easily, and the opposite end can approach lingual and palatal areas through triple angulation. Therefore, the authors studied the effect of embossed new dental pick and dental floss on periodontally involved 15 patient. The following results were obtained. 1. For embossed new dental pick, probing depth at baseline, 1 week, 4 weeks were $3.6{\pm}0.6mm$, $3.4{\pm}0.5mm$, $3.2{\pm}0.5mm$, respectively, and $4.2{\pm}0.9mm$, $4.1{\pm}0.9mm$, $4.0{\pm}0.9mm$, respectivly for clinical attachment level. 2. In case of embossed new dental pick, bleeding on probing at baseline, 1 week, 4 weeks were $43.0{\pm}4.4%$, $28.5{\pm}5.1%$, $22.2{\pm}5.6%$, respectively, and, at 1 week and 4 weeks, they were significantly different from that of dental floss. 3. Gingival index of toαhpick at baseline, 1 week, 4 weeks were $1.7{\pm}0.5$, $1.0{\pm}0.3$, $0.9{\pm}0.2$, respectively, and, $1.7{\pm}0.5$, $1.1{\pm}0.4$, $1.0{\pm}0.4$, respectively for plaque index, and $3.0{\pm}0.5$, $1.7{\pm}0.5$, $1.4{\pm}0.4$, respectively for proximal plaque index. proximal plaque index at 4 weeks was significantly different from that of dental floss. 4. The result of questionnaire showed that the two types of device were both satisfactory, however, embossed new dental pick had higher preference as well as satisfaction. As a result, embossed new dental pick is thought to be clinically effective for its simplicity and good accessibility.

레이저 조사가 치주낭 조직에 미치는 영향 (An effect of laser irradiation on periodontal pocket tissue)

  • 한경윤;김상목;김병옥;김현섭;임기정
    • Journal of Periodontal and Implant Science
    • /
    • 제26권2호
    • /
    • pp.511-521
    • /
    • 1996
  • Periodontal pocket is one of the most frequently developed clinical feature on the teeth with periodontal disease. In order to determine the gingival curettage effect of intrapocket irradiation of a pulsed Nd : YAG laser on periodontally involved teeth, bilateral 60 teeth with $4{\sim}6mm$ in probing pocket depth 1 week after supragingival scaling were selected. On half of them the intrapocket irradiation($300{\mu}m$ fiber optic, 1.5W power, for 2min.) of a pulsed-Nd : YAG laser(EL.EN.EN06O, Italy) was applied as the lased group. On the contralateral 30 teeth the subgingival curettage was accomplished by Gracey curettes as the curattage group. The periodontal pocket tissues were surgically excised by the modified Widman flap technique immediately after the intrapocket irradiation or subgingival curettage, subsequently fixed with 10% neutral formalin, sectioned in $4{\sim}6{\mu}m$ thickness, and stained with hematoxylin-eosin. Surface characteristics and incomplete removal of the pocket epithelium were evaluated under light microscope. And the difference between the lased group and the curettage group was statistically analyzed by Chi-square test in Microstat program. The results were as follows ; 1. The plane surface was observed more frequently in the curettage group(73.3%) than in the lased group(23.3%), and the rough surface was observed more frequently in the lased grOoup(63.3%) than in the curettage group(6.7%)(p<0.05). 2. The rate of incomplete removal of the pocket epithelium was relatively high in both the lased group(76.6%) and the curettage group(86.6%), and there was no significant difference between the lased group and the curettage group(p>0.l). The results suggest that the further studies including various power control of laser should be succeeded in order to obtain more favorable results by the intrapocket irradiation of a pulsed Nd:YAG laser than the subgingival curettage with Gracey curettes.

  • PDF