• 제목/요약/키워드: geothermal heating and cooling

검색결과 189건 처리시간 0.023초

R410A 대체냉매 적용 지열히트펌프 개발 (The development of a ground source heat pump using R410A)

  • 김지동;정봉철;정일권
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.17-22
    • /
    • 2007
  • The growth of domestic energy demand is rapidly increased for the industrialization and the improvement of the living standards. It is also recognised that the importance of the use of environmentally friendly energy and high efficient equipment. Ground Source heat pumps (GSHP) using earth as heat source or sink are outstanding environmentally friendly energy systems which have high thermal efficiency when compared to conventional heating and cooling system. So government employs a policy and increase investment for expanding renewable energy market volume. Especially is established a system for obligatory usage of renewable energy to achieve 5% renewable energy diffusion rate by 2011. And the market demand for the ground source heat pump is rapidly growing due to its strong advantages. However domestic situation usually have been depended on the import of ground source heat pumps. In this paper, the results of development of a ground source heat pump using refrigerant R410A are reported.

  • PDF

에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구 (The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance)

  • 윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구 (Energy Saving by Combination of Element Technologies of Zero-Energy House)

  • 신현철;장건익
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

지하수 열원 열펌프 개발을 위한 지하수 온도의 변화 특성 연구 (A Study on the Variation of Ground Water Temperature for Development of Ground Water Source Heat Pump)

  • 남현규;김영일;서정아;신영기
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권2호
    • /
    • pp.1-6
    • /
    • 2005
  • Ground water source heat pumps are clean, energy-efficient and environment-friendly systems for cooling and heating. Although the initial cost of ground water source heat pump system is higher than that of air source, it is now widely accepted as an economical system since the installation cost can be returned within a short period of time due to its high efficiency. In a ground water source heat pump system, the variation of the ground water temperature is an important factor that influences the system performance. In this study, variation of the ground water temperature of a single well system is studied experimentally for various operating conditions. When ground water flow exists in the underground, the returned water exchanges heat efficiently with the ground and the temperature of the ground water remains nearly constant. Hence the short circuit problem is minimized. If an active flow of ground water flow exists in the underground, a singe well heat pumps system will be free of short circuit problem and can operate with high performance.

  • PDF

지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구 (A Study on the Certified Ground Source Heat Pump and Performance Analysis)

  • 양찬우;강희정;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.

에너지슬래브 지중열교환기의 성능 분석 (Performance Analysis of Energy-Slab Ground-Coupled Heat Exchanger)

  • 최종민;손병후
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.487-496
    • /
    • 2012
  • Recently, utilization of building foundations as ground-coupled heat exchangers has attracted much attention because they reduce the cost and enhance the heat transfer. The objective of this study is to evaluate the performance of energy-slab ground-coupled heat exchanger installed in a commercial building. In order to demonstrate the energy transfer characteristics of the energy-slab, experiments were conducted from October 2010 to September 2011. The 1-year measurement results showed that the mean EWTs of brine returning from the energy-slab were $9.6^{\circ}C$ in heating season and $24.9^{\circ}C$ in cooling season, which were in a range of design target temperatures. In addition, the geothermal heat pump system with the energy-slab showed on-off operation according to the setting temperatures of secondary fluid in water storage tank. The results also showed that the energy-slab extracted heat of 198.6 kW from the ground and injected heat of 318.9 kW to the ground, respectively.

단독주택 건물 그린리모델링에 따른 건물 에너지 성능과 운전비용 절감 효과 평가 (Energy Performance and Operating Cost Assessment for Implementing Green Remodeling Technologies in a Detached House)

  • 손병후;이수인;강재식
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.27-38
    • /
    • 2023
  • The Government the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of buildings and to promote green growth policy in construction sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. Green remodeling reinforced the insulation of the exterior walls and roofs of the buildings and replaced high-efficiency windows and doors. In this study, the energy performance before and after green remodeling applied in a detached house was comparatively analyzed for baseline scenario and three different ones, ALT 1, ALT 2 and ALT 3. A building modeling and simulation software (DesignBuilder V7.0) with EnergyPlus (V9.4) calculation engine was used to calculate the energy demand and energy consumption for each scenario. Based on the calculation results of the building's energy demand for baseline, it was determined that the target building required more heating energy than cooling energy. The simulation results also showed that the implementation of building envelope performance improvement technologies (ALT 1) could notably decrease the heating energy consumption of the building. After the remodeling (ALT 1), the source energy consumption per unit floor area was assessed to be reduced by 65.2%, compared to prior remodeling of 338.7 kWh/m2 -y. Meanwhile, ALT 2 can achieve energy savings of 67.7% and ALT 3 can achieve savings of 73.1%. Following completion of the remodeling project, actual construction costs, and on-site measurements and verification results will be gathered and compared with the simulation results. Additionally, economic analysis including construction costs and payback period will be conducted using actual site data.

지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰 (A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment)

  • 조윤주;이진용;임수영;홍경표
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권3호
    • /
    • pp.22-31
    • /
    • 2009
  • 최근 에너지 위기와 지구 온난화의 영향으로 국내에서 건물의 냉난방에 지열에너지를 비롯한 재생에너지의 사용이 증가하고 있다. 지열히트펌프시스템은 지금까지 지구상에서 가장 환경친화적인 냉난방 공조설비의 하나로 알려져 있다. 그러나 지열히트펌프시스템의 설치 및 운영이 토양 지하수환경에 미칠 수 있는 몇 가지 영향들에 대한 보고가 있다. 이들 영향으로는 주로 지열히트펌프시스템의 부적절한 설치, 운영 및 폐쇄와 관련된다. 본 논문에서는 지열히트 펌프시스템이 토양 지하수환경에 미칠 수 있는 영향에 관하여 고찰하였다.

제어 방식에 따른 지열 히트펌프 시스템의 성능 시뮬레이션 (Performance Simulation of Geothermal Heat Pump (GHP) System with Different Control Schemes)

  • 이두영;최재호;민경천;손병후
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.35-41
    • /
    • 2016
  • 지열 히트펌프 시스템에서 히트펌프 등 시스템 구성 요소의 에너지 소비량을 효율적으로 관리하면, 냉난방 성능을 더 높일 수 있다. 본 논문은 외기온도 제어 방식이 지열 시스템의 성능에 미치는 영향을 분석하였다. 또한 분석 결과를 현재 국내에서 주로 적용하는 제어 방식(Control-A)과 비교하였다. 이를 위해 상용 소프트웨어(TRNSYS 17)를 이용하여 가상 지열 시스템의 모델을 구축한 후, 시뮬레이션을 수행하였다. 외기 온도 제어 방식(Control-B)은 버퍼 탱크의 온도를 외기 온도에 따라 제어하기 때문에, 간절기 때 효과적이었다. 기존 제어 방식과 비교했을 때, 외기 온도 제어 방식은 히트펌프 전력 소비량을 7.7%(147 kWh 절감) 그리고 순환펌프 전력 소비량을 7.5%(28.1 kWh 절감) 줄일 수 있었다.

열교환기의 흐름개선을 통한 고효율 지열 히트펌프 시스템에 관한 연구 (A Study on High Efficiency Geothermal Heat Pump System by Improving Flow of Heat Exchanger)

  • 안성환;최재상;김상범;안형환
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.42-46
    • /
    • 2017
  • 화석연료의 무분별한 사용으로 인한 이산화탄소의 대기 중 방출은 지구의 연평균 기온을 상승시키는 원인으로 작용하고 있다. 이를 해결하기 위한 대체에너지로써 지열은 연중 일정한 온도를 갖는 무한자원이다. 지열에너지를 널리 보급하기 위해서는 히트펌프의 성능과 지중열교환기의 열교환 효율이 매우 중요하다. 이에 본 연구는 히트펌프의 성능을 증가시키기 위해 팽창변을 이중으로 구성하고 지중열교환기의 열교환 효율을 높이기 위해 입출관과 유입관 사이에 간격유지부재를 사용하여 실험하였다. 실험한 결과 팽창변을 이중으로 구성하였을 때 냉난방 능력이 최대 11.4%가 증가됨을 얻을 수 있었고, 간격유지부재를 사용 시 열교환 효율이 17.5% 향상되었다. 이러한 결과를 토대로 지열시스템의 설치 시 히트펌프의 성능과 지중열교환기의 열교환 효율의 상승으로 인해 설치비용이 많이 절감될 것으로 판단된다.