• Title/Summary/Keyword: geometric mean diameter

Search Result 57, Processing Time 0.029 seconds

Yellow Sand Phenomena Influence to the Atmosphere in Korea (黃砂現象이 우리나라에 미치는 影響)

  • 이민희;한의정;원양수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.34-44
    • /
    • 1986
  • Particle size distribution of airborne suspended particulate concentrations according to particle size in the events of yellow sand phenomena, have been measured and analyzed by using Andersen air sampler for four years, January 1982 through December 1985. The conclusions are as follows: 1. Yellow sand phenomena, generally, occur between March and May. 2. The frequent occurrences of yellow sand were observed during March and April and airborne suspended particulate concentrations in the cases of yellow sand appeared to be 2 $\sim$ 3.4 times higher than those of normal conditions. 3. Geometric mean particle diameter and its geometric mean standard deviation by logarithmic normal distribution sheet, were quite close to each other and log-distribution curves showed similar shapes. 4. Analysis by particle size distribution curve showed bi-modal distribution. 5. Concentrations of coarse particles in normal conditions were 1.2 $\sim$ 2 times higher than those of fine particles and, similarly, coarse particle concentrations in yellow sand cases were 1.3 $\sim$ 2.5 times higher than those of fine particles. 6. Concentrations of coarse particles in yellow sand cases were 2 $\sim$ 3.6 times higher than those in normal conditions and those of fine particles were 1.7 $\sim$ 3.5 times higher.

  • PDF

A Study on Airborne Coal Dust Concentration at each Work Site in Coal Briquet Factory (연탄제조 공장의 작업장별 석탄분진의 농도에 관한 연구)

  • 신대윤;오정룡;강공언
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.6-11
    • /
    • 1992
  • This study was carried out to investigate exposure level, size distribution, and respirable mass fraction of airborne coal dust and heavy metal concentration of respirable coal dust at each work site in coal briquet factory from July 1991 to September 1991. Geometric mean of total dust concentration was 10.88mg/m$^{3}$ at storage shop, 8.22mg/m$^{3}$ at pulverize shop, and 3.79mg/m$^{3}$ at rotary press shop, respectively, but those at storage and pulverize shop were higher than TLV. Geometric mean of respirable coal dust concentration wat 1.03mg/m$^{3}$ at storage shop, 0.78mg/m$^{3}$ at pulverize shop, and 0.55mg/m$^{3}$ at rotary press shop, respectively, which were lower than TLV Aerodynamic 50% cutoff diameter of the suspended coal dust was 5$\mu$m at rotary press shop and 6.8$\mu$m at storage shop, ranged to thoracic particulate defined by ACGIH, and deposited in the region of repiratory system. The mass fraction rate of respirable dust to the total coal dust was 26.2% at rotary press shop, 18.8% at storage shop, and 13.8% at pulverize shop, respectively. Heavy metal concentrations of the respirable coal dust were 0.028mg/m$^{3}$ ib Fe, 0.0081mg/m$^{3}$ in Cu, and 0.0039mg/m$^{3}$ in Pb.

  • PDF

Particle Size Analysis of Cadmium Aerosol for Cadmium Inhalation Toxicology Study (766ppm Cadmium Nebulizing Solution) (카드뮴의 흡입독성 연구를 위해 설계된 에어로졸 발생장치에서 발생된 카드뮴 에어로졸의 입경분석(766ppm 카드뮴 네뷸라이징 용액))

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Jahng Doo Sub;Kang Sung He;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.5
    • /
    • pp.1035-1041
    • /
    • 2002
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit and 766ppm Cd nebulizing solution were used to generate cadmium aerosol for inhalation toxicology study. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 43.449 x 10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 43.211 x 10³ in inlet temperature 100 ℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 41.917x10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter(GMD) were 0.677-1.009㎛ in source temperature 20℃, 0.716-0.963㎛ in source temperature 50℃, and 0.724-0.957㎛ in source temperature 70℃. The smallest GMD was 0.677㎛ in source temperature 20℃ and inlet temperature 20℃. and the largest GMD was 1.009㎛ in source temperature 20℃ and inlet temperature 20℃. The ranges of geometric standard deviation(GSD) were 1.635-2.101 in source temperature 20℃. 1.676-2.073 in source temperature 50℃, and 1.687-2.051 in source temperature 70℃. The lowest GSD was 1.635 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.101 in source temperature 20℃ and inlet temperature 200℃. Aerosol generated for cadmium inhalation toxicology study was polydisperse aerosol. The ranges of mass median diameter(MMD) were 1.399-5.270㎛ in source temperature 20℃. 1.593-4.742㎛ in source temperature 50℃, and 1.644-4.504㎛ in source temperature 70℃. The smallest MMD was 1.399㎛ in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 5.270㎛ in source temperature 20℃ and inlet temperature 200℃. Increasing trends for GMD, GSD, and MMD were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4㎛. In our results. inlet temperature 20 and 50℃ in source temperature 20℃, and inlet temperature 20 to 150℃ in source temperature 50 and 70℃ were conformed to the EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3㎛. In our results, inlet temperature 20 and 50℃ in source temperature 20, 50, and 70℃ were conformed to the OECD and EU guidance.

Particle Size Analysis of Lead Aerosol with the use of 2730ppm Lead Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구를 위한 2730ppm 납 네뷸라이징 용액에서 발생된 에어로졸의 입경분석)

  • Jeung Jae Yeal;Kang Sung Ho;Kim Sam Tae;Lee Eun Kyoung;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.518-524
    • /
    • 2003
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit was made for lead inhalation toxicology study and 2730ppm lead nebulizing solution was used to generate lead aerosol. After modification of source and inlet temperatures, the results of particle size analysis for lead aerosol were as following. The highest particle counting for source temperature 20℃ was 39933.66 in inlet temperature 100℃ and particle diameter 0.75tLm. The highest particle counting for source temperature 50℃ was 39992.71 in inlet temperature 250℃ and particle diameter 0.75μm. The highest particle counting for source temperature 70℃ was 37569.55 in inlet temperature 50℃ and particle diameter 0.75μm. The ranges of geometric mean diameter(GMD) were 0.754-0.784μm for source temperature 2℃, 0.758-0.852μm for source temperature 50℃, and 0.869-1.060μm for source temperature 70℃. The smallest GMD was 0.754μm in source temperature 20℃ and inlet temperature 20℃, and the largest GMD was 1.060μm in source temperature 70℃ and inlet temperature 250℃. The ranges of geometric standard deviation(GSD) were 1.730-1.782 for source temperature 20℃, 1.734-1.894 for source temperature 50℃, and 1.921-2.148 for source temperature 70℃. The lowest GSD was 1.730 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.148 in source temperature 70℃ and inlet temperature 250℃. Lead aerosol generated in this study was polydisperse. The ranges of mass median diameter(MMD) were 1.856-2.133μm for source temperature 20℃, 1.877-2.894μm for source temperature 50℃, and 3.120-6.109μm for source temperature 70℃. The smallest MMD was 1.856μm in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 6.109μm in source temperature 70℃ and inlet temperature 250℃. Slight increases for GMD, GSD, and MMD values were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but inlet temperature 20℃ and 50℃ for source temperature 70℃ were conformed EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but none for source temperature 70℃.

Physical Properties of Rapeseed (I) (유채 종자의 물리적 특성(I))

  • Duc, L.A.;Han, J.W.;Hong, S.J.;Choi, H.S.;Kim, Y.H.;Keum, D.H.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.101-105
    • /
    • 2008
  • Some physical properties of rapeseed such as geometric properties (linear dimensions, sphericity, seed volume, surface area) and gravimetric properties (the mass of one thousand seeds, bulk density) were analyzed at five levels of moisture content of 10.03, 14.91, 20.07, 25.06 and 30.12% (w.b.). The physical properties of rapeseed were evaluated as a function of seed moisture content. In the moisture range, when the moisture content increase, sphericity decreased from 0.946 to 0.927, and geometric mean diameter, seed volume and surface area increased from 2.17 to 2.31 mm, 5.58 to $6.88 \;mm^3$ and 14.76 to $16.77\;mm^2$ respectively. Mass of one thousand seeds increased from 5.04 to 6.46 g. Bulk density decreased from 579.3 to $549.2\;kg/m^3$ due to swelling of the seed.

Study on Characteristics by Aerodynamic Diameter of Airborne Suspended Particulate Matters (대기 부유분진의 입경별 특성에 관한 연구)

  • 김성천;강달선;차영희
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.108-115
    • /
    • 2000
  • The mass fraction of PM10 had a bimodal distribution in the middle of between 2.1 ${\mu}{\textrm}{m}$, and the average mass fraction of particles less than 2.1~3.1 ${\mu}{\textrm}{m}$ was 54.1% for Pb and 890.8 ng/㎥ for Fe, respectively. For the concentration of PM10 and metallic elements by seasonal variation, PM10 showed bimodal distribution, while metallic elements showed different distributions by their sources. The ratios of fine particles to total mass were 0.45 for PM10, 0.41 for Cr, and 0.20 for Fe, 0.57 for Zn, 0.68 for Cd and 0.63 for Pb, respectively. That facts indicated that PM10, Zn, Cd, Cr and Pb were from anthropogenic sources, and Fe was from natural source. The geometric means and geometric standard deviations by seasonal variations were 3.6 ${\mu}{\textrm}{m}$ , 2.31 ${\mu}{\textrm}{m}$ in winter, 3.0 ${\mu}{\textrm}{m}$ , 2.49 ${\mu}{\textrm}{m}$ in spring, 2.7 ${\mu}{\textrm}{m}$ , 2.03 ${\mu}{\textrm}{m}$ in summer respectively. And, total efficiency of cascade impactor by seasonal variations were 49.6% in winter, 45.9% in spring and 44.5% in summer.

  • PDF

On the Contrast of Aerosol Size Distribution and Cloud Condensation Nuclei Concentrations between the East and the West of the Korean Peninsula (대관령과 영종도에서 측정한 에어러솔 크기분포 및 CCN 수농도에 관한 연구)

  • Kim, Jong Hwan;Park, Min-Su;Shim, Sungbo;Yum, Seong Soo
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.87-96
    • /
    • 2012
  • Aerosol number concentration ($N_{CN}$), size distribution and cloud condensation nuclei (CCN) concentration ($N_{CCN}$) were measured during 16-21 August 2008 at Daegwallyeong (DG) located in the eastern rural region of the Korean Peninsula. In the very next week (22-29 August 2008) the same aerosol properties were measured at Yeongjong Island (YJ) in the Yellow Sea. $N_{CN}$ for all 3 size cuts (above 3, 6 and 10 nm) was significantly higher at DG than YJ, but $N_{CCN}$ was significantly lower at the former and resulted in the $N_{CCN}/N_{CN}$ ratio more than twice higher at YJ ($0.94{\pm}0.09$ vs. $0.35{\pm}0.15$ at 0.53% supersaturation). The geometric mean diameter at DG, $53{\pm}15nm$, was much smaller than that at YJ, $91{\pm}6nm$, due to the particle formation events that were likely to have occurred continuously at DG. For given mean diameter, aerosols were more likely to act as CCN at YG compared to those at DG.

An Analysis on Spray Behavior of Liquid-thruster Injector through Pseudo-3D Distribution Measurement (준 3차원 공간분포 계측에 의한 액체 추력기 인젝터의 분무거동 해석)

  • Kim, Jin-Seok;Jung, Hun;Kim, Jeong-Soo;Kim, Sung-Cho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.141-144
    • /
    • 2008
  • Atomization characteristics and spatial distribution of the spray emanating from an injector of liquid-propellant thruster are investigated by using dual-mode phase Doppler anemometry (DPDA). Spray characteristic parameters such as the mean velocity, Sauter mean diameter (SMD), and velocity fluctuation are measured at various locations along the spray axis as well as on the radial direction. Those data are quantified in radial profile and also used to scrutinize the correlation between diameter and turbulence intensity of spray droplets. For the better visual grasp, dynamic behavior of spray droplets along the spray stream is presented through the velocity vectors projected on the plane of geometric axis of nozzle orifice and radial coordinate.

  • PDF

A Study on the Disintegration and Spreading Behavior of Fuel-spray Emanating from a Liquid-thruster Injector by Pseudo-3D Spatial Distribution Measurement (준3차원적 공간분포 계측에 의한 액체추력기 인젝터 연료분무의 분열 및 확산 거동에 관한 연구)

  • Kim, Jin-Seok;Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.9-17
    • /
    • 2008
  • Pseudo-3D spatial distribution of spray droplets is investigated by using Dual-mode Phase Doppler Anemometry (DPDA) in order to examine the disintegration and spreading behavior of spray exiting from liquid-propellant thruster injector. Spray injected from nozzle orifice with length-to-diameter ratio ($L/d_o$) of 1.67 and under the injection pressure of 27.6 bar is aligned to the vertical. Vertical and horizontal mean velocities of droplets, Sauter Mean Diameter (SMD), and volumetric flux decrease as droplets travel from center/upstream toward outer region/downstream of spray. Although the distribution of spray characteristic parameters is symmetric against the geometric axis of nozzle orifice, their absolute values are asymmetric.

The Measurement of Oil Globule Size Distribution in the Soymilk Suspended with the Soybean Particle (대두입자가 분산된 두유에서 기름입자의 입도분포 측정)

  • Chung, J.B.;Yoon, S.K.;Sohn, H.S.
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 1990
  • Although the measurement of oil globule size distribution is necessary to detect the process of demulsification, the reasonable methodology for its measurement has not been suggested because the solution of soymilk contains insoluble soybean particle and the protein to interfere with the detection of oil globule or oil content. The oil globule size distribution was measured by the homogeneous suspension and cumulative method under gravitational force or centrifugal force, which were modified with Stokes' low. The geometric mean diameter of oil globules in this soymilk was $033{\mu}m\;and\;031{\mu}m$ under gravitational method and centrifugal method, respectively. The differences of oil globule size distribution in the solutions emulsified by different pressures were detected by this method. The mean diameter of the solutions treated at higher pressure was shifted to smaller size and the distribution pattern of the solutions at higher pressure became more compact around the mean diameter.

  • PDF