• Title/Summary/Keyword: generators

Search Result 1,899, Processing Time 0.034 seconds

Flow Analysis of PM/NOX Reduction System for Emergency Generator (비상발전기용 PM/NOX 저감장치의 유동특성 연구)

  • Bang, Hyo-Won;Park, Gi-Young;Lee, Seong-Wock
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.163-170
    • /
    • 2021
  • Emergency generators normally use diesel engines. The generators need to conduct weekly no-load operation inspections to ensure stable performance at emergency situations. In particular, the generators with large diesel engines mainly use rectangle type filter substrates. In order to minimize hazardous emissions generated by generators, optimizing the reduction efficiency through CFD analysis of flow characteristics of PM/NOX reduction system is important. In this study, we analyzed internal flow by CFD, which is difficult to confirm by experimental method. The main factors in our numerical study are the changes of flow uniformity and back pressure. Therefore, changes in flow characteristics were studied according to urea injector locations, selective catalyst reduction (SCR) diffuser angle, and filter porosity.

An Extension of Firmware-based LFSR One-Time Password Generators

  • HoonJae Lee;ByungGook Lee
    • International journal of advanced smart convergence
    • /
    • v.13 no.2
    • /
    • pp.35-43
    • /
    • 2024
  • In this paper, we propose two 127-bit LFSR (Linear Feedback Shift Register)-based OTP (One-Time Password) generators. One is a 9-digit decimal OTP generator with thirty taps, while the other is a 12-digit OTP generator with forty taps. The 9-digit OTP generator includes only the positions of Fibonacci numbers to enhance randomness, whereas the 12-digit OTP generator includes the positions of prime numbers and odd numbers. Both proposed OTP generators are implemented on an Arduino module, and randomness evaluations indicate that the generators perform well across six criteria and are straightforward to implement with Arduino.

Disinfective Properties and Ozone Concentrations in Water and Air from an Ozone Generator and a Low-temperature Dielectric Barrier Discharge Plasma Generator (오존발생기와 저온 유전체장벽 플라즈마를 이용한 오존 발생 및 살균력)

  • Lee, Young Sik;Jeon, Hyoung-Joo;Han, Hyung-Gyun;Cheong, Cheong-Jo
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.937-944
    • /
    • 2013
  • Ozone concentrations in water and air, and resulting disinfective properties, were measured following generation by either an ozone generator or a low-temperature dielectric barrier discharge plasma generator. In freshwater, ozone concentrations of 0.81 and 0.48 mg/L $O_3$ were observed after the ozone and plasma generators had been operated for five minutes, respectively. Higher levels of dissolved $O_3$ were attained more easily with the ozone generator. In seawater, both systems were capable of creating concentrations greater than 3.00 mg/L $O_3$ after 5minutes of operation. Higher ozone levels were attained more easily in seawater than in freshwater. Rates of bacterial sterilization in seawater after three minutes were 96% and 88%, using the plasma and ozone generators, respectively. In freshwater, higher concentrations of ozone were released into the atmosphere by the ozone generator than by the plasma generator. In creating equivalent levels of dissolved ozone in freshwater, the plasma generator released 4.5 times more ozone into the atmosphere than did the ozone generator. This shows that ozone generators are more effective than plasma generators for creating ozonated water. For the same concentration of dissolved ozone in seawater, more ozone was released into the atmosphere using the ozone generator than using the plasma generator. Therefore, with regard to air pollution, plasma generators seem to be less expensive than ozone generators.

Design and Verification of Disturbace Observer based Controller for Windturbine with Two Cooperative Generators (두 대의 협력적인 발전기를 갖는 풍력발전기의 외란관측기 기반 제어기의 설계 및 검증)

  • Lee, Kook-Sun;Cho, Whang;Back, Ju-Hoon;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.2
    • /
    • pp.301-308
    • /
    • 2017
  • This paper proposes a disturbance observer based controller design method for generating and yawing control of windturbine with two cooperative generators. Windturbine system with two cooperative generators is a distinct structure in which the wind energy supplied by blade axis is converted into electrical energy by two cooperative generators. In this structure, two generators can be controlled independently and therefore they can generate power, simultaneously performing yawing control of nacelle without extra yawing mechanism by cooperatively controlling generating load in appropriate manner. Using this structural trait, this paper designs a disturbance observer based controller that enables the windturbine system with cooperative generators to generate and yaw stably, and verifies the performance of the controller experimentally by applying it to a small-scale windturbine system with the same structure.

Modeling Planned Maintenance Outage of Generators Based on Advanced Demand Clustering Algorithms (개선된 수요 클러스터링 기법을 이용한 발전기 보수정지계획 모델링)

  • Kim, Jin-Ho;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.4
    • /
    • pp.172-178
    • /
    • 2006
  • In this paper, an advanced demand clustering algorithm which can explore the planned maintenance outage of generators in changed electricity industry is proposed. The major contribution of this paper can be captured in the development of the long-term estimates for the generation availability considering planned maintenance outage. Two conflicting viewpoints, one of which is reliability-focused and the other is economy-focused, are incorporated in the development of estimates of maintenance outage based on the advanced demand clustering algorithm. Based on the advanced clustering algorithm, in each demand cluster, conventional effective outage of generators which conceptually capture maintenance and forced outage of generators, are newly defined in order to properly address the characteristic of the planned maintenance outage in changed electricity markets. First, initial market demand is classified into multiple demand clusters, which are defined by the effective outage rates of generators and by the inherent characteristic of the initial demand. Then, based on the advanced demand clustering algorithm, the planned maintenance outages and corresponding effective outages of generators are reevaluated. Finally, the conventional demand clusters are newly classified in order to reflect the improved effective outages of generation markets. We have found that the revision of the demand clusters can change the number of the initial demand clusters, which cannot be captured in the conventional demand clustering process. Therefore, it can be seen that electricity market situations, which can also be classified into several groups which show similar patterns, can be more accurately clustered. From this the fundamental characteristics of power systems can be more efficiently analyzed, for this advanced classification can be widely applicable to other technical problems in power systems such as generation scheduling, power flow analysis, price forecasts, and so on.

THE GENERATORS OF COMPLETE INTERSECTION

  • Kang, Oh-Jin;Ko, Hyuong-J.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.37 no.4
    • /
    • pp.829-841
    • /
    • 2000
  • We classify complete intersections I of grade 3 in a regular local ring (R, M) by the number of minimal generators of a minimal prime ideal P over I. Here P is either a complete intersection or a Gorenstein ideal which is not a compete intersection.

  • PDF

Integrated High-Voltage Generators for Low-Power Bistable LCD Drivers

  • Doutreloigne, Jan;Hendrix, Wim
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.135-138
    • /
    • 2004
  • This paper describes the architecture, the basic operation principle and detailed experimental results of digitally programmable high-voltage generators that can be used in monolithic low-power high-voltage bistable LCD drivers. Two different design approaches, depending on whether the application allows the use of external passive components or not, are analyzed.

  • PDF

FUZZY SUBMACHINES OF A FUZZY FINITE STATE MACHINE

  • Hwang, Seok-Yoon
    • Journal of applied mathematics & informatics
    • /
    • v.19 no.1_2
    • /
    • pp.457-466
    • /
    • 2005
  • In this paper we present the concepts of fuzzy submachine, which are the generalized form of crisp submachine of a fuzzy finite state machine. Also we extend the concepts of system of generators to fuzzified form.

AUTOMORPHISMS OF K3 SURFACES WITH PICARD NUMBER TWO

  • Kwangwoo Lee
    • Bulletin of the Korean Mathematical Society
    • /
    • v.60 no.6
    • /
    • pp.1427-1437
    • /
    • 2023
  • It is known that the automorphism group of a K3 surface with Picard number two is either an infinite cyclic group or an infinite dihedral group when it is infinite. In this paper, we study the generators of such automorphism groups. We use the eigenvector corresponding to the spectral radius of an automorphism of infinite order to determine the generators.