• 제목/요약/키워드: generator failure

검색결과 164건 처리시간 0.024초

Complications Following Permanent Transvenous Endocardial Pacemaker Implantation (Cardiac pacemaker implantation 의 합병증)

  • 왕영필
    • Journal of Chest Surgery
    • /
    • 제10권2호
    • /
    • pp.219-225
    • /
    • 1977
  • Pacemaker therapy has been established as a routine procedure in a variety of disturbances of :cardiac rhythm. Cardiac pacing has greatly reduced the mortality rate in patients suffering from bradyarrhythmias complicated by Stokes-Adams attacks. However, in spite of the simplicity of the treatment and reliability of the devices available today, patients and physicians alike are invovled in a multitde of pacemaker specific problems. Clinical experience with permanent transvenous pacing during a 3 year period is presented. A total of 20 pacemaker operations were performed in 13 patients. The complications in our 20 pacemaker operations were headed by skin ulceration of 3 generator pockets and early dislocation of 3 electrodes. In an additional 2 patient, stimulation of diaphragm due to a position of electrode in the coronary sinus was noticed in one and battery failure of pulse generator was detected in the other. Literatures were reviewed.

  • PDF

Process and instrument faults detection based on steam generator model (증기발생기 모델을 이용한 계통 및 계측기 고장검출에 관한 연구)

  • Kim, Jung-Soo;Lyou, Joon;Na, Nan-Ju;Kwon, Kee-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.250-255
    • /
    • 1993
  • In this paper, for detection and isolation of instrument and process faults related with steam generator(S/G) in nuclear power plant, two types of observers are designed based on the linearized dynamic model of S/G : a bank of Dedicated Observers (DOS) for instrument faults detection and a bank of Unknown Input Observers(UIO) for process faults detection. And then, they are combined to decide which one between the above two faults occurs. In principle, the failure in ith instrument(process) can be isolated by monitoring the error between the ith output and its estimation obtained from the ith DOS(UIO). It is shown via computer simulations that the present scheme is feasible in finding out the source of a fault.

  • PDF

On Hunting Protected Circuit at the Inflow about Load direction Harmonics of a Small Size the Generator (소형 발전기의 부하측 고조파 유입시 HUNTING 방지회로)

  • Bae, Jong-Il;Park, Byeong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2668-2670
    • /
    • 2002
  • The generators of a small size below 100Kw are often used as power suppliers for emergency only in most domestic telecommunication companies. Serious twisted waves occur due to the inflow of harmonies from the generator into a S-type rectifier. And the increasing by stages of load upon the rectifier end up a stoppage of power supply during the serious hunting, which makes it difficult to supply power securely on the other part as well as that of communications. In case of long time of power failure the generators of a small size will be essential because the battery for emergency has a limit in capacity. Therefore it is necessary to solve the problems concerning the generators. This study is focused on the identifying and solving the problem including use of SCR elements connected to the generators.

  • PDF

A Design of Load Shedding System Considering both Angular Stability and Voltage Stability in Industrial Power System (산업용 전력계통의 주파수 안정도와 전압 안정도를 고려한 부하차단 설계)

  • Kim, Bong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제53권3호
    • /
    • pp.103-109
    • /
    • 2004
  • This paper has presented, taking an example of a gas separation plant, dynamic analysis on frequency decline caused by the over-loading at the generator and the knee point causing voltage instability due to reactive power required by re-acceleration of large induction motors, resulting in phenomena of failure in the conventional frequency load shedding. In order to resolve the voltage instability problem, a design of load shedding system employing under-voltage relays has been proposed to the industrial power system containing large induction motors in addition to the conventional load shedding employing frequency relays. For the purpose of dynamic analysis, models of gas turbine and governor, synchronous generator, brushless exciter, and induction motor are introduced.

Flow-Induced Vibration Test in the Preheater Region of a Steam Generator Tube Bundle

  • Kim, Beom-Shig;Hwang, Jong-Keun
    • Nuclear Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.85-91
    • /
    • 1997
  • Cross-flow existing in a shell-and-tube steam generator can cause a tube to vibrate. There are four regions subjected to cross-flow in Yonggwang units 3 and 4 (YGN 3 and 4) steam generators, which are of the same design as the steam generators for Palo Verde nuclear power plant Palo Verde units 1 and 2 steam generators have experienced localized oar at the comers of the cold side recirculating fluid inlet regions. A number of design modifications were made to preclude tube failure in specific regions of YGN 3 and 4 steam generators. Therefore, flow induced vibration experiments were done to determine the vibration magnitude of tubes in the economizer tube free lane region. The objective of this experiment is to demonstrate that the tube displacement is less than 0.01 inch rms at 100% of full power flow and to quantify the remaining design margin at 120ft and 140% of full power flow.

  • PDF

Application of particle filtering for prognostics with measurement uncertainty in nuclear power plants

  • Kim, Gibeom;Kim, Hyeonmin;Zio, Enrico;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1314-1323
    • /
    • 2018
  • For nuclear power plants (NPPs) to have long lifetimes, ageing is a major issue. Currently, ageing management for NPP systems is based on correlations built from generic experimental data. However, each system has its own characteristics, operational history, and environment. To account for this, it is possible to resort to prognostics that predicts the future state and time to failure (TTF) of the target system by updating the generic correlation with specific information of the target system. In this paper, we present an application of particle filtering for the prediction of degradation in steam generator tubes. With a case study, we also show how the prediction results vary depending on the uncertainty of the measurement data.

Calculating Mean Life of Generators with Aging failures Data Using Data Analytic Method (통계적 분석 방법을 이용한 발전설비의 평균수명 계산)

  • Lee Sung Hoon;Lee Seung Hyuk;Kim Jin O;Jeon Dong Hoon;Kim Tae Kyun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.464-466
    • /
    • 2004
  • This paper proposes a method to consider an aging failure probability and survival probability of power system components unlike uses only aging failure probability in existing mean life calculation. The estimates of the mean and its standard deviation is calculated by using Weibull distribution and each estimated parameters is obtained from Data Analytic Method (Type II Censoring). The parameter estimation using Data Analytic Method is simpler and faster than a traditional calculation method. This paper shows how to calculate the mean life and its standard deviation by the proposed method and illustrates a exactness using real historical records of generator utilities in korea.

  • PDF

Fabrication of Microcantilever Ultrasound Sensor and Its Application to the Scanning Laser Source Technique

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제25권6호
    • /
    • pp.459-466
    • /
    • 2005
  • The scanning laser source (SLS) technique has been proposed recently as an effective way to investigate small surface-breaking defects, By monitoring the amplitude and frequency changes of the ultrasound generated as the SLS scans over a defect, the SLS technique has provided enhanced signal-to-noise performance compared to the traditional pitch-catch or pulse-echo ultrasonic methods, An extension of the SLS approach to map defects in microdevices is proposed by bringing both the generator and the receiver to the near-field scattering region of the defects, To facilitate near-field ultrasound measurement, silicon microcantilever probes are fabricated using microfabrication technique and their acoustical characteristics are investigated, Then, both the laser-generated ultrasonic source and the microcantilever probe are used to monitor near-field scattering by a surface-breaking defect.

Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG (배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • 제28권6호
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.