• Title/Summary/Keyword: generalized

Search Result 8,537, Processing Time 0.04 seconds

Two Cases of Acute Poststreptococcal Glomerulonephritis Superimposing to IgA Nephropathy (IgA 신병증에 병발한 급성 연쇄상구균 감염후 사구체신염)

  • Kim Young Kyoun;Lee Jun Ho;Hahn Hyewon;Ha Il Soo;Cheong Hae Il;Choi Yong
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.154-160
    • /
    • 2000
  • The pathogenesis of IgA nephropathy and acute poststreptococcal glomerulonephritis is not fully understood. In the past, acute poststreptococcal glumerulonephritis was the most common cause of gross hematuria in children, but now IgA nephropathy is the most common one. We experienced two cases of acute poststreptococcal glomerulonephritis superimposing to IgA nephropathy in boys Case 1 had upper respiratory infection before elevation of anti-streptolysin O, generalized edema, gross hematuria and proteinuria. The complement levels were normal. Electron microscopic findings of renal biopsy at ten days after onset showed a few big subepithelial 'humps' and localized heavy subendothelial and mesangial deposits. Immunofluoroscopic findings revealed predominant IgA deposition in the mesangium. The electron microscopic findings were diagnostic of acute poststreptococcal glomerulonephritis On the other hand, immunoflorescence microscopic findings were compatible to IgA nephropathy. In case 2, the renal biopsy which was done 2 years after onset showed only finding of IgA nephropathy. To our knowledges, there has been kw reports of acute poststreptococcal glomerulonephritis superimposing to IgA nephropathy which was confirmed by renal biopsy. We report two cases of acute poststreptococcal glomerulonephritis superimposing: to IgA nephropathy with a brief review of the literatures.

  • PDF

Optimal Strategy of Hybrid Marketing Channel in Electronic Commerce (전자상거래하에서의 하이브리드 마케팅 채널의 믹스 전략에 관한 연구)

  • Chun, Se-Hak;Kim, Jae-Cheol
    • Asia pacific journal of information systems
    • /
    • v.17 no.2
    • /
    • pp.83-95
    • /
    • 2007
  • We are motivated by how offline and online firms compete. The Internet made many conventional offline firms build a dynamic online business as another sales channel using their advantages such as brand equity, an existing customer base with comprehensive purchasing data, integrated marketing, economies of scale, and longtime experience with the logistics of order fulfillment and customer service. Even though the hybrid selling using both offline and online channel seems to have advantages over a pure online retailer, all the conventional offline firms are not seen to create an online business. Many conventional offline firms began to launch online business since the Internet era, however, just being online business is not likely to guarantee success. According to Bizate.com's report whether the hybrid channel strategy is successful is still under investigation. For example, consider the classic case of Barnes and Noble versus Amazon.com, Barnes and Noble was already the largest chain of bookstores in the U,S., when Amazon.com was established in 1995, BarnesandNoble.com followed suit in 1997, After suffering losses in its initial years, Amazon finally turned profitable in 2003. In 2004, Amazon's net income was $588 million on revenues of $6.92 billion, while Barnes and Noble earned $143 million on revenues of $4.87 billion, which included BarnesandNoble.com's loss of $21 million on revenues of $420 million. While these examples serve to motivate our thinking, it does not explain when offline firms should venture online. It also does not provide an analytical framework that can generalized to other competitive online-offline situations. We attempt to do this in this paper and analyze a hybrid channel model where a conventional offline firm competes against online firms using its own direct online channels. We are particularly interested in an optimal channel strategy when a conventional offline firm sells its products through its own direct online channel to compete with other rival online firms. We consider two situations where its direct online channel and other online firms are symmetric and asymmetric in the brand effect. The analysis of this paper presents several findings. In the symmetric model where a hybrid firm's online channel is not differentiated from a pure online firm, (i) a conventional offline firm will not launch its online business. In the asymmetric model where a hybrid firm's online channel is differentiated from a pure online firm, (ii) a conventional offline firm can launch its online business if its brand effect is greater than a certain threshold. (iii) there is a positive relationship between its brand effect and online customer costs showing that a conventional offline firm needs more brand effect in order to launch online business as online customer costs decrease. (iv) there is a negative relationship between its brand effect and the number of customers with access to the Internet showing that a conventional offline firm tends to launch its online business when customers with access to the Internet increases.

The Strength and Applications of OSB Gusset Trusses for Field Assembly (현장조립용 OSB 덧댐판 트러스의 강도 및 활용방안)

  • Kim, Tae-Woo;Ha, Bin;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.708-713
    • /
    • 2014
  • Trusses are widely used for wooden houses in the areas where wood construction in generalized for residential housings such as North America, Australian, New Zealand. In Korea, joist and rafter system is generally used because of the production cost, transportation cost and lack of experience required for truss manufacturing. In this study, roof trusses and flat trusses were manufactured by using oriented strand board (OSB) gusset plates for field assembly and tested under bending load to obtain the allowable loads. The allowable load and the actual load of 6m span roof trusses were 10.60 kN and 5.26 kN, respectively, which is regarded to be sufficient for use in construction. The allowable load and the actual load of 6m span floor flat trusses were 7.18 kN and 7.43 kN, respectively. For flat trusses, the allowable load is slightly lower than the actual load but the difference in very small, and it is thought that flat trusses can be used for construction by applying small change of structures and members.

A Study on the Evaluation of Simplification Algorithms Based on Map Generalization (지도 일반화에 따른 단순화 알고리즘의 평가에 관한 연구)

  • Kim, Kam-Lae;Lee, Ho-Nam;Park, In-Hae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1992
  • The digital map database is often produced for multiple purposes, including mapping at multiple scales; it is increasingly rare that a base map is digitized for mapping at a single scale. The most important problems in process of line simplification in map generalization and multiple representation is that tolerance value selected for simplifying base map information must be modified as feature geometry varies within the digital file to ensure both accuracy and recognizability of graphic details on a generalized map. In this study, we explored various algorithms regarding to line simplication at many scales from a single digital file, and presents a rule by which to determine those scale at which line feature geometry might be expected to change in map representation. By applying two measured of displacement between a digitized line and its simplification, five algorithms have been evaluated. The results indicate that, of the five, the Douglas-Peucker routine produced less displacement between a line and its simplification. The research has proved to automating map simplification, incorporating numeric guidelines into digital environment about what magnitude and variation in geometric detail should be preserved as the digital data is simplified for representation at reduced map scales.

  • PDF

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF

Estimation of Future Design Flood Under Non-Stationarity for Wonpyeongcheon Watershed (비정상성을 고려한 원평천 유역의 미래 설계홍수량 산정)

  • Ryu, Jeong Hoon;Kang, Moon Seong;Park, Jihoon;Jun, Sang Min;Song, Jung Hun;Kim, Kyeung;Lee, Kyeong-Do
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.139-152
    • /
    • 2015
  • Along with climate change, it is reported that the scale and frequency of extreme climate events show unstable tendency of increase. Thus, to comprehend the change characteristics of precipitation data, it is needed to consider non-stationary. The main objectives of this study were to estimate future design floods for Wonpyeongcheon watershed based on RCP (Representative Concentration Pathways) scenario. Wonpyeongcheon located in the Keum River watershed was selected as the study area. Historical precipitation data of the past 35 years (1976~2010) were collected from the Jeonju meteorological station. Future precipitation data based on RCP4.5 were also obtained for the period of 2011~2100. Systematic bias between observed and simulated data were corrected using the quantile mapping (QM) method. The parameters for the bias-correction were estimated by non-parametric method. A non-stationary frequency analysis was conducted with moving average method which derives change characteristics of generalized extreme value (GEV) distribution parameters. Design floods for different durations and frequencies were estimated using rational formula. As the result, the GEV parameters (location and scale) showed an upward tendency indicating the increase of quantity and fluctuation of an extreme precipitation in the future. The probable rainfall and design flood based on non-stationarity showed higher values than those of stationarity assumption by 1.2%~54.9% and 3.6%~54.9%, respectively, thus empathizing the necessity of non-stationary frequency analysis. The study findings are expected to be used as a basis to analyze the impacts of climate change and to reconsider the future design criteria of Wonpyeongcheon watershed.

Analysis of Repeated Measured VAS in a Clinical Trial for Evaluating a New NSAID with GEE Method (퇴행성 관절염 환자를 대상으로 새로운 진통제 평가를 위한 임상시험자료의 GEE 분석)

  • Lim, Hoi-Jeong;Kim, Yoon-I;Jung, Young-Bok;Seong, Sang-Cheol;Ahn, Jin-Hwan;Roh, Kwon-Jae;Kim, Jung-Man;Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • Objective : To compare the efficacy between SKI306X and Diclofenac by using generalized estimating equations (GEE) methodology in the analysis of correlated bivariate binary outcome data in Osteoarthritis (OA) diseases. Methods : A randomized, double-blind, active comparator-controlled, non-inferiority clinical trial was conducted at 5 institutions in Korea with the random assignment of 248 patients aged 35 to 75 years old with OA of the knee and clinical evidence of OA. Patients were enrolled in this study if they had at least moderate pain in the affected knee joint and a score larger than 35mm as assessed by VAS (Visual Analog Scale). The main exposure variable was treatment (SKI 306X vs. Diclofenac) and other covariates were age, sex, BMI, baseline VAS, center, operation history (Yes/No), NSAIDS (Y/N), acupuncture (Y/N), herbal medicine (Y/N), past history of musculoskeletal disease (Y/N), and previous therapy related with OA (Y/N). The main study outcome was the change of VAS pain scores from baseline to the 2nd and 4th weeks after treatment. Pain scores were obtained as baseline, 2nd and 4th weeks after treatment. We applied GEE approach with empirical covariance matrix and independent(or exchangeable) working correlation matrix to evaluate the relation of several risk factors to the change of VAS pain scores with correlated binary bivariate outcomes. Results : While baseline VAS, age, and acupuncture variables had protective effects for reducing the OA pain, its treatment (Joins/Diclofenac) was not statistically significant through GEE methodology (ITT:aOR=1.37, 95% CI=(0.8200, 2.26), PP:aOR=1.47, 95% CI=(0.73, 2.95)). The goodness-of-fit statistic for GEE (6.55, p=0.68) was computed to assess the adequacy of the fitted final model. Conclusions : Both ANCOVA and GEE methods yielded non statistical significance in the evaluation of non-inferiority of the efficacy between SKI306X and Diclofenac. While VAS outcome for each visit was applied in GEE, only VAS outcome for the fourth visit was applied in ANCOVA. So the GEE methodology is more accurate for the analysis of correlated outcomes.

Evaluated the L-spine Magnetic Resonance Imaging for the Scanning Method of the Lateral Recumbent Position with to the Embarrassed Control of the Acute Low Back Pain (자기공명검사에서 통증제어가 불가능한 급성 요통 환자의 옆으로 누운 자세에 대한 영상평가)

  • Lee, Jaeheun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.255-260
    • /
    • 2014
  • The acute lumbar pain patients who were unavoidable to take MRI examination were made to take altered lateral recumbent position. they were also not able to control their painfulness and to be in supine position. In this study, it is supposed to increase success rate of the MRI examination through taking the altered lateral recumbent position in using spine and body matrix coil. This altered position made relaxing lumber pain and fatigue for the patients who suffered from sever lumber pain. In these reasons, it decreases the motion artifacts through correcting uncomfortable posture. As a result, qualitative analysis for the image quality was estimated to have average points of supine position A group(lateral recumbent position) of normal candidates and B group(lateral recumbent position) of the abnormal candidates who have sever pain at 4.64, 3.44, and 3.40, respectively. In conclusion, while qualitative analysis in the examination with supine position of the normal patients had significantly high points, the qualitative analysis in the examination with lateral recumbent position of the normal patients and abnormal patients who had sever lumbar pain was almost same. In addition, it was judged that radiologists' imagery interpretation had no other problems in the image evaluation of B group who had acute lumbar pain of abnormal patients. Hereupon, if this technique becomes generalized for the patients who suffer from supine position in the examination, it is supposed to be useful in medical field.

Application of SWAT-CUP for Streamflow Auto-calibration at Soyang-gang Dam Watershed (소양강댐 유역의 유출 자동보정을 위한 SWAT-CUP의 적용 및 평가)

  • Ryu, Jichul;Kang, Hyunwoo;Choi, Jae Wan;Kong, Dong Soo;Gum, Donghyuk;Jang, Chun Hwa;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.347-358
    • /
    • 2012
  • The SWAT (Soil and Water Assessment Tool) should be calibrated and validated with observed data to secure accuracy of model prediction. Recently, the SWAT-CUP (Calibration and Uncertainty Program for SWAT) software, which can calibrate SWAT using various algorithms, were developed to help SWAT users calibrate model efficiently. In this study, three algorithms (GLUE: Generalized Likelihood Uncertainty Estimation, PARASOL: Parameter solution, SUFI-2: Sequential Uncertainty Fitting ver. 2) in the SWAT-CUP were applied for the Soyang-gang dam watershed to evaluate these algorithms. Simulated total streamflow and 0~75% percentile streamflow were compared with observed data, respectively. The NSE (Nash-Sutcliffe Efficiency) and $R^2$ (Coefficient of Determination) values were the same from three algorithms but the P-factor for confidence of calibration ranged from 0.27 to 0.81 . the PARASOL shows the lowest p-factor (0.27), SUFI-2 gives the greatest P-factor (0.81) among these three algorithms. Based on calibration results, the SUFI-2 was found to be suitable for calibration in Soyang-gang dam watershed. Although the NSE and $R^2$ values were satisfactory for total streamflow estimation, the SWAT simulated values for low flow regime were not satisfactory (negative NSE values) in this study. This is because of limitations in semi-distributed SWAT modeling structure, which cannot simulated effects of spatial locations of HRUs (Hydrologic Response Unit) within subwatersheds in SWAT. To solve this problem, a module capable of simulating groundwater/baseflow should be developed and added to the SWAT system. With this enhancement in SWAT/SWAT-CUP, the SWAT estimated streamflow values could be used in determining standard flow rate in TMDLs (Total Maximum Daily Load) application at a watershed.

Surgical Treatment of the Pseudoaneurysm of the Ascending Aorta Following the Repair of Congenital VSD -1 case report- (선천성 심실중격결손증 교정술 후 발생한 가성 상행대동맥류 수술 치험 -1례 보고-)

  • An, Byeong-Hui;Kim, Gwang-Hyu;Na, Guk-Ju;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.564-568
    • /
    • 1996
  • Pseudoaneurysm of the ascending aorta following cardiac surgery is very unusual and it is poten- tially fatal. We report here a fourteen year-old female patient with pseudoaneurysm of the ascending aorta following a repair of a congenital ventricular septal defect at other hospital 50 months ago. Although she had a mild superficial wound infection postoperatively, she enjoyed uneventful. life until she visited our hospital for a generalized weakness and exertional dyspnea which developed a month ago. Chest CT and echocardiogram showed partially calcified pseudoaneurysm of the ascending aorta. Two aortic defects were located on the anterolateral ascending aortic wall wkere it was suspected as a previous sites of aortic and cardioplegic cannulation. The internal wall of the pseudoaneurysm was covered with neoendothelium and intervened by septal tissue. Two defects on he aortic wall were oval in shape and about 1.5cm in the greatest diameter The defects were trimmed to make a one large de- fect and it was reconstructed with patch designed from 22mm collagen impregnated double velour Dacron graft. The postoperative course was uneventful.

  • PDF