• Title/Summary/Keyword: gc/ms

Search Result 2,427, Processing Time 0.034 seconds

Study on the analytical method using GC-MS for the accident preparedness substances (실험실 GC-MS를 이용한 사고대비물질 분석방법 연구)

  • Kim, Kijoon;Lee, Jinseon;Lee, Suyeong;Hwang, Seungryul;Kim, Younghee;Seok, Gwangseol
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.80-85
    • /
    • 2013
  • The sixty nine accident preparedness substances (APS) having high probability of chemical accident are controlled under the Toxic Chemicals Control Act (TCCA). Around the world, there has been a growing interest in the analysis of chemical warfare agent (CWAs). When a chemical accident occurs, it is generally required to detect and identify APS. However, the quantitative analytical data remain limited in Korea. In this study, an analytical method using GC/MS for volatile organic chemicals was established and a quantitative analysis method was studied. The calibration curve for 25 chemicals were obtained and 21 chemicals showed higher coefficient of determination ($r^2$ >0.998).

Analysis of Lacquer and CNSL Using Infrared Spectrometer and Pyrolysis-GC/MS (적외선분광분석과 Py-GC/MS를 이용한 옻칠 및 캐슈칠도막 분석)

  • Choi, Jaewan;Kim, Soo-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Nowadays, synthetic resin varnish such as cashew nut shell liquid (CNSL) is being used as well as traditional lacquer. The code of ethics states that material must be identical to the original when preserving cultural heritage. Therefore, lacquer should be used. However, problem is that even experts have difficulties differentiating lacquer and CNSL as they have similar components. Therefore, this study was carried out to identify the difference between lacquer and CNSL using IR and Py-GC/MS. As a result of IR, in lacquer, $720cm^{-1}$ peak was detected and in CNSL, $750cm^{-1}$, $720cm^{-1}$ and $700cm^{-1}$ peaks were detected. The results of Py-GC/MS detect benzene compounds and alkyl chains for both varnishes. However, hexanoic acid was detected from CNSL but not lacquer. Using these analytical methods, the differences between lacquer and CNSL can be identified on the scene. This is expected to be applied to the authentic conservation and restoration of lacquerware.

Evaluation of a Method for the Measurement of PAHs in the Ambient Atmosphere - Focusing on High Volume Sampling and GC/MS Analysis (대기 중 다환방향족탄화수소 측정방법의 성능평가 - 하이볼륨 샘플링 및 GC/MS 분석방법을 대상으로)

  • Seo, Young-Kyo;Park, Dae-Kwon;Baek, Sung-Ok
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.322-333
    • /
    • 2009
  • In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on $8"{\times}10"$ quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.

GC-MS Analysis of Chemical Constituents from Various Agarwood (GC-MS를 이용한 침향류의 성분 비교 연구)

  • Shin, Kwhang-Ho;Choi, Kyu-Yeol;Cho, Sung-Yong;Ahn, Duk-Kyun;Park, Seong-Kyu
    • The Korea Journal of Herbology
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • Objectives : The purpose of this study is to evaluate the quality of four different kinds of agarwood and analysis chemical constituents by GC-MS. Methods : Four source plants were two of Vietnamese agarwood, Indonesian agarwood and Myanmar agarwood. These plant materials were named sample No. 1-4. The chemical constituents of each agarwood were analysed by GC-MS. Results : GC-MS analysis showed that ${\beta}$-selinene was found in all the samples. The Vietnamese agarwood, Sample 1, and 4 has contained 6.861% and 7.497% of ${\beta}$-selinene and reached the highest level at the retention times 46.245 and 46.274 (min). Sample 2, the Myanmar agarwood has contained 1.608%, the lowest level of ${\beta}$-selinene, and it also has contained about 20% of ${\alpha}-,{\beta}-,{\gamma}$-eudesmol and 4.076% of valerianol. Sample 3, the Indonesian agarwood has contained 9.59% of ${\beta}$-selinene, 9.493% of ${\beta}$-selinene and shown its highest level (more than 19%) at the retention time 43.998 (min). Conclusion : It suggested that ${\beta}$-selinene could be a standard marker to evaluate agarwood by GC-MS analysis.

Semiquantitative Dynamic Headspace GC-MS Analysis for Organic Compounds Outgassed from FAB Materials of Air Shower (에어샤워부품의 용출 가스 중 유기화합물의 반 정량적 Headspace GC-MS 분석)

  • Park, Hyun-Mee;Baig, Soung-Woo;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.412-422
    • /
    • 2000
  • The polymeric FAB materials of air shower used in clean room of wafer industry have been outgassed with the dynamic headspace (ca.$100^{\circ}C$) for half an hour, and analyzed using GC-MS. The air in the clean room running air shower was sampled using sorbent tube method, and the organic compounds adsorbed in the sorbent tube were extracted using Soxhlet extraction method, and analyzed using GC-MS. The analytical results from FAB materials of air shower (electric over current relay, acryl plate. polycarbonate window, filter, fan housing, steel galvanized cold plate and canvas buffer) indicated that most of chemicals were originated from polymer fragments of FAB materials. Their analytical results have been compared with those from the air of clean room running air shower. These comparative results could lead to identify whether the sources of trace organic contaminants in clean room air are originated from the polymeric FAB material of air shower.

  • PDF

Analysis of Multi-layered Thin Film Using ATR FT-IR and pyro-GC/MS (ATR FT-IR과 pyro-GC/MS를 이용한 다층박막필름의 분석)

  • Park, Sung Il;Lee, Jung-Hyun;Lee, Myung Cheon
    • Journal of Adhesion and Interface
    • /
    • v.20 no.3
    • /
    • pp.102-109
    • /
    • 2019
  • The material constitution of multi-layered thin film coated on the PET base film was analyzed using ATR FT-IR and pyro GC/MS combination. The cross section of the film was acquired by cracking the film after dipping in liquid nitrogen and was observed using optical microscope. Total thickness of the coated film was $70{\mu}m$ and three layers were observed. Since each layers were too thin to analyze directly except the surface layer, analyzable area of each layers were exposed by using a proper solvent and were investigated using ATR FT-IR and pyro GC/MS. Results shows that three layers were commonly consisted of urethane-acrylate copolymers. Also, inorganic and/or metal inclusions detected by XPS and SEM-EDAX were exhibited by nano size $SiO_2$ particles in layer(1) and aluminum flakes in layer(2).

Synthesis of DMDBTDMA and determination of radiolysis products by GC/MS (DMDBTDMA의 합성 및 방사선 분해산물의 GC/MS 분석)

  • Yang, Han-Beom;Lee, Eil-Hee;Park, Gyo-Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.403-411
    • /
    • 2008
  • Dimethyldibutyltetradecylmalonamide (DMDBTDMA) extractant was used in a solvent extraction process for a radioactive liquid waste treatment. For the study of radiolysis phenomena, DMDBTDMA was synthesized and the degradation compounds (n-methylbutylamine, tetradecane, 1-tetradecanol) in the DMDBTDMA extractant, irradiated with $^{60}Co$ gamma ray, were identified and determined as radiolysis products by a Fourier transform infrared (FT-IR), gas chromatograph/mass spectrometer (GC/MS) analysis and GC/MS with selected ion monitoring (SIM) mode. Retention behavior of n-methylbutylamine, n-dodecane, tetradecane and 1-tetradecanol in the total ion chromatogram with the standard materials and n-dodecane as the internal standard (ISTD) were 2.35 min., 8.83 min., 10.68 min. and 12.75 min., respectively. In the case of tetradecane, there was a linear relationship between the concentration of the tetradecane and the absorbed dose of the ${\gamma}$-ray irradiated DMDBTDMA.

Development of Simultaneous Analysis for Multiple Agricultural Pesticides in Raw Milk Products using GC-MS/MS (GC-MS/MS를 이용한 원유 원료 중 농약 동시분석법 확립)

  • Young Nae Choi;Yoon ho Shin;Hwangeui Cho;Jung Bok Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.420-429
    • /
    • 2023
  • GC-MS/MS using liquid-liquid extraction (LLE) and C18 cartridges was used to identify and quantify levels of chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin and permethrin in bulk raw milk. A calibration curve spanning 10 ng/mL to 200 ng/mL was obtained with a satisfactory correlation coefficient of 0.99. The limits of detection (LOD) and limits of quantitation (LOQ) for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in the matrix ranged from 0.06 to 1.81 ng/mL and 0.19 to 6.04 ng/mL, respectively. The recoveries of 5 pesticides from spiked samples at 37.5-125 ng/mL ranged from 86.1 to 102.1%. The measurement of uncertainty of the GC-MS/MS method for these five pesticides was developed based on the analytical process and quantification. An analysis method that is easier and faster than the method specified in the Korean food standards codes for analyzing these five pesticides in raw material milk was developed. Moreover, the analytical method for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in bulk raw milk by GC-MS/MS was established.

Determination of Quintozene Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Quintozene의 잔류분석)

  • Ahn, Kyung-Geun;Kim, Gyeong-Ha;Kim, Gi-Ppeum;Hwang, Young-Sun;Hong, Seung-Beom;Lee, Young Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.195-203
    • /
    • 2015
  • Quintozene, pentachloronitrobenzene (PCNB) is a contact fungicide for control of soilborne phytopathogenic fungi during cultivation of diverse crops. It was introduced to agricultural use around 1930's as a substitute for mercurial disinfectants. Although quintozene had been first registered in Korea on 1969. However, now it was banned to use due to its high residue levels in selected harvest products. Also, high possibility is expected that the residue may be contained in imported agricultural commodities as it is still used widely over the world. Therefore, this study was conducted to establish a determination method for quintozene residue in crops using GC/ECD/MS. Quintozene residue was extracted with acetonitrile from representative samples of five raw products which comprised hulled rice, soybean, Kimchi cabbage, green pepper, and apple. The extract was diluted with saline water, and n-hexane partition was followed to recover quintozene from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The quintozene was quantitated by GLC with ECD, using a DB-1 capillary column. The crops were fortified with quintozene at 3 levels per crop. Mean recoveries ranged from 79.9% to 102.7% in five representative agricultural commodities. The coefficients of variation were less than 4.3%. Quantitative limit of quintozene was 0.004 mg/kg in representative five crop samples. A GC/MS with selected-ion monitoring was also provided to confirm the suspected residue. Therefore, this analytical method was reproducible and sensitive enough to determine the residue of quintozene in agricultural commodities.

Identification of Lignan Compounds in Fruits of Schisandra chinensis BAILLON by Gas Chromatography/Mass Spectrometry (GC/MS에 의한 오미자 Lignan성분의 동정)

  • Sohn, Hyun-Joo;Bock, Jin-Young
    • Applied Biological Chemistry
    • /
    • v.32 no.4
    • /
    • pp.344-349
    • /
    • 1989
  • Eleven lignan compounds in fruits of Schisandra chinensis BAILLON were identified by gas chromatography/mass spectrometry(GC/MS). The GC/MS conditions were as followed: the GC column used was SPB-1 fused silica capillary $(0.25mm\;id{\times}30m,Supelco)$ and the column oven temperature was programmed from $200^{\circ}C$ to $300^{\circ}C$ at the rate of $4^{\circ}C$ per minute; the MS ionization voltage was 70eV (EI mode). The compounds identified were gomisin J $(M^+;\;388)$, deoxyschizandrin$(M^+;\;416)$, gomisin N $(M^+;\;400)$, schizandrin$(M^+;\;432)$, wuweizisu C $(M^+;\;384)$, gomisin A $(M^+;\;416)$, angeloylgomisin H $(M^+;\;500)$, tigloylgomisin H $(M^+;\;500)$, angeloylgomisin Q $(M^+;\;530)$, gomisin B $(M^+;\;514)$ and benzoylgomisin H $(M^+;\;522)$, peaks of which were separated well on the GC chromatogram.

  • PDF