• Title/Summary/Keyword: gauge group

Search Result 176, Processing Time 0.031 seconds

Effect of artificial shrinkage on clinical outcome in fresh blastocyst transfer cycles

  • Hur, Yong-Soo;Park, Jeong-Hyun;Ryu, Eun-Kyung;Yoon, Hae-Jin;Yoon, San-Hyun;Hur, Chang-Young;Lee, Won-Don;Lim, Jin-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.2
    • /
    • pp.87-92
    • /
    • 2011
  • Objective: This study aimed to determine the safety and clinical effect of artificial shrinkage (AS) in terms of assisted hatching of fresh blastocysts. Also, we evaluated the correlation between patient age and the effect of AS on clinical outcome. Methods: Two AS methods, using a 29-gauge needle and laser pulse, were compared. Seventy-three blastocysts were shrunk using a 29-gauge needle and the same number of other blastocysts were shrunk by a laser pulse. We evaluated the shrunken blastocysts hourly and considered them viable if they re-expanded >70%. Blastocyst transfer cycles (n=134) were divided into two groups: a control group consisted of the cycles whose intact embryos were transferred (n=100), while the AS group consisted of the cycles whose embryos were replaced following AS (n=34). The implantation and pregnancy rates of the control group and AS group were compared ($p$ <0.05). Results: The re-expansion rates of the 29-gauge needle and laser pulse AS groups were similar (56 [76.7%] vs. 62 [84.9%], respectively). All of the remaining shrunken blastocysts were re-expanded within 2 hours. There was no degeneration of shrunken blastocysts. The total and clinical pregnancy rate of the AS group (23 [67.6%]; 20 [58.8%], respectively) was significantly higher than that of the control group (47 [47.0%]; 39 [39.0%], respectively). In the older patient group, there was no difference in the clinical outcomes between the AS and control groups. Conclusion: These results suggest that AS of blastocoele cavity, followed by the transfer, would be a useful approach to improve the clinical outcome in cycles in which fresh blastocyst stage embryos are transferred.

Design of Two-DOF Optimal Controller for Strip Gage and Tension Control of Cold Tandem Mills Using Reference Shaping Filter and Disturbance Observer (목표치 정형화 및 외란 관측기를 활용한 연속 냉간압연 시스템의 2-자유도 스트립 두께 및 장력 최적 제어기 설계)

  • Hong, Wan-Kee;Kang, Hyun-Seok;Hwang, I-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.237-244
    • /
    • 2012
  • This paper studies the design of a two-DOF optimal controller for the strip gauge-tension of cold tandem mill processes, that uses a reference shaping filter and a disturbance observer. First, a mathematical model of the strip gauge and tension system is constructed using the gauge meter equation and Hooke's law, respectively. Next, a two-DOF controller considering of a feedforward controller and a feedback controller is designed. The former is based on the reference shaping filter and the disturbance observer, and the latter is based on the ILQ optimal control algorithm. Finally, it is shown through a computer simulation that the proposed optimal controller is able to improve the strip gauge accuracy and the tension variation more than the conventional MV-AGC controller.

A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE (Strain gauge를 사용한 임플랜트 인상법의 정확도 비교)

  • Han, Eu-Taek;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Assessment of sediment profiles applying nuclear techniques: use of a nucleonic gauge in Panama Canal watershed

  • Xavier Sanchez;Henry Hoo;Patrick Brisset;Reinhardt Pinzon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4236-4243
    • /
    • 2022
  • An industrial nuclear technique based on the use of an X-ray profiler was implemented to estimate the densities or concentrations of sediments present in an Atlantic maritime zone in the areas subjected to dredging under the governance of the Panama Canal Authority (ACP). The sediment profiles show in most areas there is a concentration of between 1.00-1.15 g/cm3 except for one area in particular, the density starts at 1.20 g/cm3 and even reaches values greater than 1.50 g/cm3; therefore, an already consolidated sediment is present, which, depending on the depth found. Values of 1.265 g/cm3, 1.297 g/cm3, 1.185 g/cm3 obtained by ACP previous studies are within the range of 1.20-1.30 g/cm3 measured with the nucleonic gauge. However, it should be noted that during the tests with the X ray profiler, sediment densities values greater than the aforementioned limit were also obtained that varying according at depths close to 12 m and 18 m with values reached up to 1.513 g/cm3 and 1.60 g/cm3, respectively. This demonstrates that sediment accumulation depends on depth. This nucleonic gauge is feasible technique for the study of the sedimentation phenomenon in channel basins and even in other projects nationwide.

ON THE HOMOLOGY OF THE MODULI SPACE OF $G_2$ INSTANTONS

  • Park, Young-Gi
    • Communications of the Korean Mathematical Society
    • /
    • v.9 no.4
    • /
    • pp.933-944
    • /
    • 1994
  • Let $\pi : P \to S^4$ be a principal G-bundle over $S^4$ whose the structure group G is a compact, connected, simple Lie group. Since $\pi_3(G) = \pi_4 (BG) = Z$, we can classify the principal bundle $P_k$ over $S^4$ by the map $S^4 \to BG$ of degree k. Atiyah and Jones [2] showed that $C_k = A_k/g^b_k$ is homotopy equivalent to $\Omega^3_k G \simeq \Omega^4_k BG$ where $A_k$ is the space of the all connections in $P_k$ and $g^b_k$ is the based gauge group which consists of all base point preserving automorphisms on $P_k$. Here $\Omega^nX$ is the space of all base-point preserving continuous map from $S^n$ to X. Let $M_k$ be the space of based gauge equivalence classes of all connections in $P_k$ satisfying the Yang-Mills self-duality equations, which we call the moduli space of G instantons.

  • PDF

An Experiment on How the Length and the Diameter of the sprue Effects the Size of the porosity, that is Created During the Moduling Process (주조 시 발생되는 porosity가 sprue의 길이와 굵기에 따라 주조체에 미치는 영향에 관한 실험적 연구)

  • Hwang, Seung-Sig
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • This experiment was done to find out how the length and the diameter of the sprue effects the porosity created during the moduling process, which is caused by the metal's shrinking and stretching action. the experiment was done in two groups(A and B), using experimental gold, and made 10 copings for both groups. 1. In group A, The length of the sprues were given the same, but the diameter of the sprue were 6, 8, 10, 12, 18 gauge. As a result, the porosity came out big with 12 and 18 gauge and for 10, 8, 6 gauge, the porosity was hardly seen or none was noticeable. 2. In group B, the diameter was given the sam for the sprues, but the length of the sprues were 5, 10, 15, 20, 25mm. As a result, the porosity came out big with 25, 20, 15mm the porosity was hardly seen or none was noticeable. 3. The diameter needs to be big and the length, short. 4. The appropriate sized sprue must be chosen for each individual tooth, according to it's shape and size.

  • PDF

Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses

  • Lee, Mi-Young;Heo, Seong-Joo;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.312-318
    • /
    • 2013
  • PURPOSE. The aim of this study was to compare the passivity of implant superstructures by assessing the strain development around the internal tapered connection implants with strain gauges. MATERIALS AND METHODS. A polyurethane resin block in which two implants were embedded served as a measurement model. Two groups of implant restorations utilized cement-retained design and internal surface of the first group was adjusted until premature contact between the restoration and the abutment completely disappeared. In the second group, only nodules detectable to the naked eye were removed. The third group employed screw-retained design and specimens were generated by computer-aided design/computer-aided manufacturing system (n=10). Four strain gauges were fixed on the measurement model mesially and distally to the implants. The strains developed in each strain gauge were recorded during fixation of specimens. To compare the difference among groups, repeated measures 2-factor analysis was performed at a level of significance of ${\alpha}$=.05. RESULTS. The absolute strain values were measured to analyze the magnitude of strain. The mean absolute strain value ranged from 29.53 to 412.94 ${\mu}m/m$ at the different strain gauge locations. According to the result of overall comparison, the cement-retained prosthesis groups exhibited significant difference. No significant difference was detected between milled screw-retained prostheses group and cement-retained prosthesis groups. CONCLUSION. Within the limitations of the study, it was concluded that the cement-retained designs do not always exhibit lower levels of stress than screw-retained designs. The internal adjustment of a cement-retained implant restoration is essential to achieve passive fit.

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.

THE IRRIGATING EFFECT BEFORE AND AFTER CORONAL FLARING (Coronal flaring 전, 후의 근관세척효과)

  • Hwang, Ho-Keel;Bae, Seong-Chul;Cho, Young-Lin
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.72-79
    • /
    • 2003
  • The objective of this in vitro study was to evaluate the efficacy of a Ca(OH)$_2$removal before and after early coronal flaring using different types of instruments. 100 plastic blocks with 30$^{\circ}$artificial curved canals were used in this study and randomly divided into a control group and 4 experimental groups(GG, OS, GT, PT Group) 20 teeth each. The canals were instrumented, and Ca(OH)$_2$was temporary filled into the each canal. Irrigation was peformed with Max-i-Probe 25- 30-gauge probes before and after recapitulation. The results of this study were as follows 1. There were no significant difference among the groups in size of irrigating needle(p<0.05). 2. There was a significant difference between before and after recapitulation regardless size of irrigating needle(p<0.05). 3. Before recapitulation, there was a significant difference between 25- and 30-gauge needle in all groups(P<0.05). 4. After recapitulation, there was a significant difference between 25- and 30-gauge needle in the control group(p<0.05). But there were no significant difference among the experimental groups. It is concluded that the effectiveness of canal irrigation was decided to the depth of irrigating needle into the canal. The effect of canal irrigation tend to facilitate by the early coronal flaring. The recapitulation was the most effective during canal irrigation regardless the size of irrigating needle. Therefore, the recapitulation is a mandatory way to facilitate the effectiveness of canal irrigation during canal enlargement.