• 제목/요약/키워드: gauge group

검색결과 178건 처리시간 0.031초

회전방지장치와 지대주의 내육각구조가 임플란트로 전달되는 조임 회전력에 미치는 영향 (EFFECT OF A COUNTER-TORQUE DEVICE AND THE INTERNAL HEXAGON OF ABUTMENT ON THE TIGHTENING TORQUE TRANSMITTED TO THE IMPLANT)

  • 이상민;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.223-231
    • /
    • 2003
  • Statement of problem : Little is known about the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Purpose : The purpose of this study was to examine the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Material and Methods : In this study, three types of abutment were used, (1) two-piece conical abutment with hexagon, (2) two-piece conical abutment without hexagon, and (3) one-piece conical abutment without hexagon. The experimental groups were divided into five groups according to the type of abutment and the usage of a counter-torque device. Group I : two-piece conical abutment with internal hexagon was tightened without the use of a counter-torque device. Group II : two-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group III : one-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group IV : two-piece conical abutment with internal hexagon was tightened with the use of a counter-torque device Group V : two-piece conical abutment without internal hexagon was tightened with the use of a counter-torque device. Abutments were tightened 20Ncm torque with the use of manual torque wrench and then torque values were measured by torque-gauge. After the measurement of torque values, all groups were loosened with the use of manual torque wrench and then detorque values were measured by torque-gauge. Results : The results were as follows. 1. There were no differences in torque values among three types of abutment. 2. Regardless of the existence of the internal hexagon of abutment, a counter-torque device decreased the tightening torque transmitted to the implant about 92% 3. In group III showed the highest detorque value, however there were no differences among group I, II, IV and V. Conclusion : Within the limitations of this study, it was concluded that the internal hexagon of abutment has no effect on the tightening torque transmitted to the implant and the detorque value of abutment screw. The use of a counter-torque device is essential to prevent microfracture on the implant-bone interface but has no effect on preload.

요추간판탈출증 환자의 체질침과 체침에 의한 자각적 통증감소 비교 (Comparison of the Improvement of Subjective Symptoms between Body Acupuncture Group & 8 Constitution Acupuncture Group)

  • 채상진;김남옥;박영철;손성세
    • Journal of Acupuncture Research
    • /
    • 제18권3호
    • /
    • pp.48-55
    • /
    • 2001
  • Objective : The main cause of back pain & sciatica is HNP of L-spine. Recently, 8 Constitution Acupuncture is largely used for it, but the effects isn't announced. So we studied. The perceived pain diminishment is compared with Body acupuncture and 8 Constitution acupuncture. Methods : VAS(Visual analogue scale) was used for this research, with the pain indicator of 10 and 0 which represents a patient admission to a hospital and a status of no pain respectively. Two groups, consisting of Body acupuncture group with 17 persons and 8 Constitution acupuncture group with 12 persons, was randomly allocated for this research. SPSS(Statistical Program for Social Science) for window is used for a statistical analysis, and the independent T-test is performed to gauge the improvement of VAS, in which case, value of P below 0.05 is considered as useful. Results : The result of the VAS of comparison analysis between two groups after 10 days, shows that the improvement of subjective symptoms in Body acupuncture group is more effective than that in 8 Constitution acupuncture group. (independent T-test, P=0.009)

  • PDF

EFFECT OF TIN COATING OF ABUTMENT SCREW ON DETORQUE FORCE

  • Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.329-338
    • /
    • 2007
  • Purpose. The aim of this study is to evaluate the effect of TiN coating of abutment screw on the unscrewing torque. Material and methods. Titanium and Gold-Tite abutment screws were classified into two groups, Group A and C respectively, as control groups. Titanium abutment screws with TiN coatings were also classified into two groups, Group B and D, as experimental ones. Group A and B were tightened to 20 Ncm input torque, and Group C and D were tightened to 32 Ncm torque. Detorque values were measured with digital torque gauge during repeated closing and opening experiment. Results. Abutment screws with TiN coating (Group B and D) showed statistically significant higher mean detorque values than those of Group A and C. Discussion. Physical properties of TiN coating, such as low friction coefficient, high hardness and wear resistance, might contribute to higher detorque values. Conclusion. It is suggested that TiN coating of abutment screw help to reduce the risk of screw loosening and improve the stability of screw joint.

광조사 방법에 따른 복합레진의 중합수축에 관한 연구 (A STUDY ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO VARIOUS LIGHT-CURING METHODS)

  • 권오진;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.102-109
    • /
    • 2003
  • 본 연구는 중합수축을 줄이기 위해 개발된 2단계 광조사법을 사용하여 복합레진의 중합시 발생하는 수축양상을 스트레인 게이지법(strain gauge method)으로 측정해 보고, 중합도의 비교를 위해 미세경도를 측정해 본 다음 이 결과를 기존의 광조사법과 비교해 보고자 하는 것이었다. 내경 6mm, 높이 2mm의 아크릴 주형에 복합레진인 $Z100^{TM}$(3M, USA)을 충전하였고 Curing light 2500(3M, USA)과 Elipar Highlight(ESPE, Germany)의 광조사기를 사용하였다. I 군은 광도가 $450mW/cm^2$인 Curing light 2500으로 40초간 광조사하였고, II 군은 광도가 $650mW/cm^2$인 Elipar Highlight로 40초간 광조사하였으며, III 군은 Elipar Highlight의 2단계 중합 방법을 이용하여 초기 10초간은 $150mW/cm^2$로, 나머지 30초간은 $650mW/cm^2$의 광도로 조사하였다. 스트레인 게이지법을 이용하여 광조사 후 1초 간격으로 10분간 선중합 수축률(linear polymerization shrinkage)을 측정한 다음 그래프로 분석하였고, 중합 1분 후와 10분 후의 선수축률을 측정하여 통계분석하였으며 미세경도기를 사용하여 중합 24시간 후의 각 군의 미세경도를 측정하여 통계분석하였다. 중합수축 양상을 관찰해 본 결과 각 군에서 모두 중합 초기에 일시적인 재료의 팽창을 나타내었고, 그 후 약 1분간은 수축량이 급격히 증가하다가 증가의 폭이 점차 감소하는 양상을 보였다. 전반적으로 2단계 광조사법을 사용한 III 군에서 수축률이 낮게 나타났다. 중합 후 1분과 10분에서의 선수축률을 비교해 본 결과 통상적인 광조사법을 사용한 I 군과 II 군에 비해 2단계 광조사법을 사용한 III군에서 유의하게 낮은 수축률을 나타내었다(p<0.05). 미세경도 측정결과 상면과 하면에서 모두 각 군간에 유의한 차이를 발견할 수 없었다.

  • PDF

다공 세라믹 컵을 이용한 디지털 토양수분 장력계 개발 (Development of a Digital Soil Tensiometer using Porous Ceramic Cups)

  • 정인규;장영창;김기복;김용일;정선옥
    • Journal of Biosystems Engineering
    • /
    • 제32권6호
    • /
    • pp.448-454
    • /
    • 2007
  • This study was conducted to develop a 100 kPa soil tensiometer mainly consisted of a porous ceramic cup, water-holding tube, and a digital vacuum gauge, through theoretical design analysis and experimental performance evaluation. Major findings were as follows. 1. Theoretical analysis showed that air entry value of a porous media decreased as the maximum effective size of the pore increased, and the maximum diameter of the pores was $2.9\;{\mu}m$ for measuring up a 100 kPa of soil-water tension. 2. Property analysis of tensiometer porous cups supplied in Korean domestic market indicated that main components were $SiO_2$ and $Al_2O_3$ with a porosity range of $33.8{\sim}49.3%$. 3. The porous cup selected through sample fabrication and air-permeability tests showed weight ratios of 87% and 11% for $Al_2O_3$ and $SiO_2$. The analysis of SEM (scanning electron microscope) images showed that the sample was sintered at temperatures of about $1150^{\circ}C$, which consisted of pores with sizes of up to 25% of those for commercial porous cups. 4. The prototype soil tensiometer was fabricated using the developed porous cup and a digital vacuum gauge that could measure water tension with a pressure of 85 kPa in air tests. 5. In-soil tests of the prototype conducted during a period of 25-day drying showed that soil-water tension values measured with the prototype and commercial units were not significantly different, and soil-water characteristic curves could be established for different soils, confirming accuracy and stability of the prototype.

Relationship Between Electromyographic Activity of the Abductor Hallucis and the Pressure of a Pinch Gauge During Short Foot Exercise

  • Park, Kyung-Mi;Cynn, Heon-Seock;Choi, Houng-Sik
    • 한국전문물리치료학회지
    • /
    • 제18권4호
    • /
    • pp.19-25
    • /
    • 2011
  • The aims of this study were to investigate the correlation between the electromyographic (EMG) activity of the abductor hallucis (AbdH) and the amount of pressure measured by a pinch gauge (PG), and to compare the EMG activity of AbdH and the pressure measured by the PG during short foot (SF) exercise in subjects with pes planus and in subjects with a neutral foot alignment. Fourteen subjects were recruited for this study (pes planus group=7; neutral foot alignment group=7). A surface EMG was used to collect AbdH activity, and a PG was positioned under the first metatarsophalangeal joint to measure the pressure produced by the first metatarsal head during the SF exercise. The AbdH activity and the pressure measured by the PG showed a positive good correlation (r=.80, p<.05). The EMG activity of the AbdH and the pressure measured by the PG were significantly lower for subjects with pes planus than for subjects with a neutral foot alignment (p<.05). Based on these findings, the PG can be recommended as an effective instrument for evaluating the performance of the AbdH. It may also be beneficial for monitoring how well the SF exercise is performed, and for providing visual feedback to patients with pes planus during SF exercise in a clinical setting.

The Effects of Handicraft Activities on Hand Promptness and Grasp in the Elderly

  • Lee, Jung-Sook;Noh, Kyung-Ok;Kim, Bo-Kyoung;Choi, Wan-Suk;Lee, Sang-Min;Moon, Ok-Kon;Park, Joo-Hyun;Kim, Sung-Won
    • 국제물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.308-317
    • /
    • 2011
  • The purpose of this study was to investigate the influence of handicraft activities on hand promptness and grasp in the elderly. Subjects were comprised of 14 senior citizens between the ages of 70-85, with 7 subjects in the experiment group and 7 in the control group. Subjects in the experiment group practiced various handicrafts twice a day, while those in the control group did not participate in any special activity. The Jebsen Taylor Hand Function Test was used to evaluate the results, while a dynamometer and pinch gauge were used to measure hand promptness and grasp. The 7 senior citizens in the experiment group were able to increase their hand promptness and grasping skills. Conclusively, handicrafts can help improve hand promptness and grasp in the elderly. Furthermore, the development and improvement of such skills can have a positive influence on the daily lives of senior citizens. Such skills are expected to improve the overall neuro-function in the elderly population.

미양(微量) Morphine 지주막하(蜘蛛膜下) 주입(注入)에 의(依)한 항문각위술후(肛門脚圍術後) 제통효과(除痛效果)에 대(對)한 임상연구(臨床硏究) (Subarachnoid Morphine for Perianal Postoperative Pain Control)

  • 임화택;이영식;오흥근
    • The Korean Journal of Pain
    • /
    • 제1권1호
    • /
    • pp.98-102
    • /
    • 1988
  • In order to control the pain after hemorrhoidectomy and anal fistulectomy, 6 mg of 0.5% hyperbaric tetracaine without(control, group I) or wilt 0.3 mg(group II) or 0.5 mg (group III) of 0.1% morphine was injected with a 22 gauge spinal needle into the subarachnoid space through L 3-4 interspace of patients in lateral position. About 30 minutes in Fowler' sposition after injection, operation was performed in lithotomy position. All the patients who ha4 morphine showed remarkable relief of postoperative pain for an average of 27 hours. However, the dosage(0.3 or 0.5 mg) of morphine administered did not affect the duration of pain relief. Blood pressure, pulse rate and pupil size were unchanged in all patients. Dysuria after block developed for on average of 5,6, 13.2 and 14.6 hours in group I, II and III respectively. Most of these cases required urethral catheterization. Minor complications such as nausea, vomiting, itching, fever, burning sensation and paresthesia were observed 16.7, 20 and 20% of cases in group I, II and III respectively; however, no treatment was required.

  • PDF

스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구 (A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD)

  • 김윤철;김종수;권순원;김용기
    • 대한소아치과학회지
    • /
    • 제29권1호
    • /
    • pp.19-29
    • /
    • 2002
  • 본 연구의 목적은 다양한 중합과정에 따른 복합레진과 컴포머의 수축 양상을 스트레인 게이지법(strain gauge method)을 이용하여 평가해보고자 하는 것이었다. 광중합기는 기존의 할로겐 시스템인 XL 3000(3M, USA)과 최근 소개된 plasma arc curing 시스템인 Flipo(LOKKI, France)를 사용하였고, 충전 재료는 복합레진인 Z-100(3M, USA)과 컴포머인 Dyract AP(Dentsply, Germany)를 사용하였다. 주형과 치아 와동 내에 충전된 실험재료의 중합수축을 각각 측정하였으며, 만능시험기를 이용하여 압축강도를 측정하였다. 중합수축 측정 결과 모두 중합초기에는 일시적인 재료의 팽창을 나타냈고, 그 후 약 1분간은 수축량이 급격히 증가하다가 증가의 폭이 점차 감소하는 양상을 보였다. 전반적으로 컴포머를 사용한 군에 비해 복합레진을 사용한 군에서 중합수축이 크게 나타났으며 plasma arc curing 시스템을 사용한 군에 비해 기존의 광조사 시스템 군에서 더 큰 중합수축을 보였다. 압축 강도의 측정결과는 컴포머 군에 비해 복합레진 군에서 크게 나타났다. 이상의 결과를 종합해 볼 때, plasma arc curing unit와 컴포머의 사용은 시술시간의 단축과 항우식 효과를 감안한다면 소아치과 영역에서의 사용이 긍정적으로 고려될 수 있다고 생각된다.

  • PDF

희석된 헤파린과 생리식염수가 간헐적 말초정맥장치의 폐색, 유지기간 및 정맥염 발생에 미치는 영향 (Efficacy of 1:1000 Diluted Heparin versus 0.9% Normal Saline for Maintenance of Intermittent Intravenous Locks)

  • 박미미;김창희;조은숙;이미정;김혜숙
    • 기본간호학회지
    • /
    • 제7권2호
    • /
    • pp.208-221
    • /
    • 2000
  • The objective of this research was to compare the flushing effects using 1:1,000 diluted heparin or 0.9% normal saline in relation to needle gauge and frequency of IV medications. The comparative categories were clotting, duration of patency, and incidence of phlebitis. The design of research was a Nonequivalent Control group, Post test, Nonsynchrorized Design. The independent variable was 0.9% normal saline flushing the IV locks and the dependent variables were clotting, duration of patency, and incidence of phlebitis. Subjects were medical-surgical inpatients over 15 years old and with peripherally placed IVs who were hospitalized in a university medical center. Exclusion criteria included foreigners and those who were rejected for this research. The final sample for data analysis included 295 IV sites in 194 patients; 154 were in the saline group and 141 were in the heparin group. Subjects were assigned to have IV locks is flushed with 0.9% normal saline in the experimental group and to have IV lock flushed with 1:1,000 diluted heparin(100 units) in the control group. In order to increase reliability, the nurses who were assigned to the units involved in the study received an explanation on the standard method for locking an IV, recording method for observational data and criteria for the detection of phlebitis. Data were collected for a period of 2 weeks, from March 16, 2000 to March 29, 2000. Total duration of IV was defined the time of IV insertion to the time of discontinuation. Phlebitis was defined as the presence of the following : pain, swelling. erythema at the insertion site. Chi-square was used to determine the association between the degree of clotting, duration of patency, and incidence of phlebitis for the diluted heparin or the normal saline and needle gauge and frequency of IV medications. The results are summarized as follows : (a) There was difference in the degree of clotting between two groups($X^2=5.882$, p=.015). (b) There was no difference in the degree of duration of patency between two groups($X^2=2.439$, p=.295). (c) There was no difference in the incidence of phlebitis between two groups($X^2=0.190$, p=.663). (d) There was difference in the degree of clotting($X^2=6.209$, p=.013) and in the degree of duration of patency($X^2=6.978$, p=.031) according the needle guage between the two groups. (e) There was difference in the incidence of phlebitis($X^2=5.008$, p=.025) according to the frequencies of IV injection between two groups.

  • PDF