• Title/Summary/Keyword: gated SPECT

Search Result 65, Processing Time 0.021 seconds

Effects of Perfusion Defect on the Measurement of Left Ventricular Mass, Ventricular Volume and Post-stress Left Ventricular Ejection Fraction in Gated Myocardial Perfusion SPECT (정량적 게이트 심근관류 스펙트 검사에서 관류결손이 좌심근질량 측정과 부하 후 좌심실 용적 및 구혈률에 미치는 영향)

  • Ahn, Byeong-Cheol;Bae, Sun-Keun;Lee, Sang-Woo;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.381-391
    • /
    • 2002
  • Purpose: The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluate the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Subjects and Methods: Forty-six patients (male/female=34:12, mean age=64years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by AutoQUANT program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. Results: LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS un patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between EDVs, ESVs, EFs than patients with reversible defect. Conclusion: These results suggest that perfusion defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

Effects of Scatter Correction on the Assessment of Myocardial Perfusion and Left Ventricular Function by gated Tc-99m Myocardial SPECT (게이트 Tc-99m 심근관류 SPECT에서 산란보정이 심근관류 및 좌심실기능평가에 미치는 영향)

  • Jeong, Hwan-Jeong;Son, Hye-Kyung;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • Purpose: The purpose of this study was to evaluate the effect of scatter correction on the assessment of myocardial perfusion and left ventricular function by gated Tc-99m myocardial SPECT. Materials and Methods: Subjects were 11 normal volunteers, 20 patients with non-cardiac chest pain and 13 patients with coronary artery diseases. We classified above 3 groups into normal and diseased groups. Scatter correction was done using dual-energy-window scatter correction method (DEW-SC). We compared acquired counts, image contrast, corrected maximum relative counts, indices of left ventricular function, extent and severity of perfusion defects calculated by 'CEqual program' between scatter non-corrected and corrected images. Results: Scatter corrected studios was lower in counts by $18{\pm}3%$ than uncorrected studies, but image contrast were improved in all cases. Scatter correction using DEW-SC took 3 minutes to complete, and 512 kB memory to store. There were no significant differences among indices of left ventricular function between scatter non-corrected and corrected images. Although extents of perfusion defects were not significantly different, severity was severer in scatter corrected images. Conclusion: Scatter correction using DEW-SC is simple to do, and improves image contrast without changing other indices of myocardial perfusion and function.

  • PDF

Viability Assessment with T1-201 Rest-24 hour Delay Redistribution SPECT before Coronary Artery Bypass Graft in Coronary Artery Diseases (관상동맥 질환에서 우회로 수술 전 T1-201 휴식-24시간 지연 심근 관류 SPECT를 이용한 심근생존능의 평가)

  • Yoon, Seok-Nam;Kim, Ki-Bong;Lee, Won-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Jung-Don;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.493-501
    • /
    • 1996
  • To assess contribution of T1-201 rest-24 hour delay redistribution in detection of viable myocardium, we studied the predictive value of this redistribution in 17 patients who peformed rest-24 hour delay perfusion SPECT before bypass surgery. Regional wall motion was compared with gated SPECT in 10 patients and echocardiography in 7 patients before and after bypass surgery. Rest and 24 hour delayed uptakes were scored from 0 (normal perfusion) to 3 (defect). In rest SPECT, 56 segments showed perfusion decrease. Thirty four segments(61%) improved after surgery and were defined as viable Nineteen(34%) segments had more uptake of T1-201 at 24 hour delay, and the other 37 segments did not. In 81%(25/31) of segments with mildly decreased perfusion, wall motion after bypass surgery improved, 57% (8/14) of segments with severely decreased perfusion improved, and 9%(1/11) of segments with defects improved. In 14 among 19 segments which had more T1-201 uptakes at 24 hour delay, wall motion was improved(positive predictive value of redistribution: 74%). 20 among 37 segments which had persistent decreases in rest-24 hour redistribution improved and 17 did not(negative predictive value: 46%). Segments having severe perfusion decrease or defects showed improved wall motion after surgery in 64%(7/11), if it had redistribution at delay. Segments with either mildly decreased uptake in resting or rest-delayed redistribution showed improved wall motion in 76%(32/42). Among the 14 segments which showed improvement in wall motion, 10 had partial reversibility in stress-rest images and the other 4 had persistent perfusion defects in stress-rest images. These 4 segments were found viable only with rest-24 hour delayed perfusion SPECT. We concluded that rest T1-201 uptake or redistribution at 24 hour delay should be referred as an evidence to warrant postoperative improvement of abnormal wall motion and we could predict myocardial viability with preoperative rest-24 hour delay perfusion SPECT in the segments with rest perfusion decreases.

  • PDF

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

The Effect on The Result, in Case of the In-vitro Test Performance after an Imaging Test (핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향)

  • Moon, Ki Choon;Kwon, Won Hyun;Kim, Jung In;Lee, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.149-152
    • /
    • 2014
  • Purpose: At our hospital blood is collected from a patient before an imaging test, with the concern of any effect possible when a nuclear medicine imaging test and an in-vitro test are carried out at the same time. However, occasionally, the blood collection is performed after an imaging test, with the reasons that the patient is not properly guided or the patient doesn't follow the guide correctly. In that case, we prefer to gather blood again after a few days. The purpose of this study is not only to see whether there is any effect of an imaging test on the result of the in-vitro test performed with the blood collected after the imaging test, but also to study how many days waiting after each test is appropriate to take a blood sample, if the effect exists. Materials and Methods: From September to October 2013, blood were collected from 13 patients in our hospital regardless of age and sex each time before and after the injection of the radioactive isotope from the tests : PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan. Considering a half-life, AFP, CA19-9, CEA, TSH, and T3 were carried out right after the blood collection. In case of an iodine therapy, blood were taken each time before and after taking radioactive iodine, and, after AFP, CA19-9, and CEA, the difference between them in consistency and in cpm were compared. Results: With 10 patients after the imaging tests and 3 patients after the iodine therapy, their serum cpm was over 10,000. Over time, the cpm decreased in accordance with the half-life ($^{18}F$ 110minutes, $^{99}mTc$ 6hours, $^{201}Tl$ 72hours, $^{131}I$ 7days). Between the two cases, one before and the other after the injection of the radioactive isotope, the cpm and the results of AFP, CA19-9, CEA, TSH, and T3 from three patients each test, PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan, were very similar. In addition, in case of an iodine therapy, there was also not a meaningful difference in the cpm and the results of AFP, CA19-9, and CEA, from three patients in an iodine therapy, between the two cases, one before and the other after taking the radioactive iodine. Conclusion: In case a blood collection was performed after the imaging test which required a radioactive isotope injection, the cpm increased, differently according to the kind of the radioactive isotope. However, the results of the in-vitro tests like AFP, CA19-9, CEA, TSH, T3, etc were nearly not affected. As the result, it's considered that there will not be any significant effect also from other tests, as the result from the performed seven tests.

  • PDF

Comparison of Regional Myocardial Perfusion, Left Ventricular Volume and Ejection Fraction between 8- and 16-Frame Gated SPECT (8-단위영상과 16-단위영상으로 얻은 게이트 심근관류 스펙트에서 국소 심근관류, 좌심실 용적과 구혈률의 비교)

  • Lee, Sang-Woo;Lee, Jae-Tae;Bae, Jin-Ho;Jeong, Shin-Young;Chun, Kyung-Ah;Ha, Jeoung-Hee;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.269-277
    • /
    • 2003
  • 목적: 게이트 심근관류 스펙트는 심근의 관류와 좌심실 기능을 동시에 평가할 수 있는 유용한 방법이다. 현재, 게이트 영상 획득시 8 단위영상이 널리 사용되지만, 아직 가장 적절한 단위영상의 수에 대해서는 논의의 여지가 있다. 본 연구는 동일한 환자에서 8 단위영상과 16 단위영상으로 게이트 심근관류 스펙트를 2회 연속적으로 시행하여 국소적 심근관류, 좌심실 용적과 구혈률등을 비교하였다. 대상 및 방법: 42명(평균 연령: 55세, 남: 녀=26: 16)의 관상동맥 질환이 의심되거나 알려진 환자를 대상으로 안정시 Tc-99m MIBI를 이용한 게이트 스펙트를 8 단위영상과 16 단위영상으로 2회 연속하여 시행하였다. 좌심실의 확장기말 용적, 수축기말 용적과 구혈률을 각각 얻었으며 확장기말의 단층영상을 18 분절로 나누고 각 분절마다 심근의 관류정도를 4등급으로 나누어 국소적 심근관류를 평가하였다. 결과: 8 단위영상과 16 단위영상 게이트 스펙트에서 국소적 심근관류의 일치도는 85.7% (tau-b=0.786, p<0.001)로 우수하였다. 두 방법간에 1등급의 차이는 100 분절(13.2%), 2등급 차이는 8 분절(1.1 %)이 있었고 3등급 차이는 없었다. 좌심실의 확장기말 용적, 수축기말 용적, 구혈률은 두 방법간에 높은 상관성을 보였으며(r=0.993, 0.989, 0.935), 좌심실 구혈률은 8 단위영상을 사용할 때 평균 1.8% 낮게 측정되어 통계적인 유의성은 있었으나(p<0.05), 그 차이는 크지 않았다. 결론: 8 단위영상과 16 단위영상을 사용한 게이트 심근관류 스펙트에서 국소적 심근관류의 일치도는 우수하였으며, 좌심실의 기능적 계수의 차이도 크지 않았다. 비록 높은 단위영상을 사용했을 때 더 정확하고 자세한 정보를 얻을 수 있다 하더라도, 구혈률과 용적 등을 얻는 일상적인 임상검사에는 8 단위영상 또한 그 역할을 충분히 할 수 있을 것으로 사료된다.

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF