• 제목/요약/키워드: gas measurement

검색결과 1,916건 처리시간 0.033초

가스수집시간을 이용한 유중수소가스 측정감도 향상 연구 (Sensitivity Enhancement in Measurement of Hydrogen Gas Dissolved in Oil using Gas Collection Time)

  • 허종철;선종호;강동식;정주영;박정후
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.539-543
    • /
    • 2009
  • This paper describes the sensitivity enhancement in measurement of the hydrogen gas dissolved in oil using gas collection time. On-line gas measurement is a useful for continuous monitoring of power transformer. Recently many studies on hydrogen gas measurement, due to their simplicity and low price, have been done for transformer monitoring. In measurement of the hydrogen gas in oil, the suitable sensitivity and resolution in the desired ranges of the gas concentrations are needed for the reliable monitoring of power transformers. In this study, the sensor output trends were analyzed with the hydrogen gas collection time which means the time to collect the hydrogen gas before reaction of hydrogen gas sensor. It is indicated that the sensor outputs were increased with the increase of hydrogen gas collection times at the same hydrogen gas concentrations.

쓰레기 매립지 가스 포집관에서 가스조성에 따른 계측오차의 최소화 (Minimizing the Measurement Error from Gas Compositions of Gas Vent in Sanitary Landfill)

  • 이해승;이문형
    • 환경위생공학
    • /
    • 제17권1호
    • /
    • pp.28-35
    • /
    • 2002
  • 본 연구 목적은 계측저항이 없는 열선유속계를 이용하여 매립지 가스의 유량을 산정할 때 가스조성에 의해 발생되는 계측오차를 최소화할 수 있는 방안을 제시하고자하였다. Rotor meter와 가스조성 밀도를 이용하여 산정한 관 중심유속을 계측저항이 없는 열선유속계를 이용하여 구한 관 중심유속을 비교함으로서 계측오차를 측정하였다. 실험결과 열선 유속계와 rotor meter를 이용한 매립지 가스유속 계측오차의 최소화 방안을 통하여 매립지 가스유량의 오차 범위를 10% 이내로 최소화 할 수 있는 것으로 조사되었다.

인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석 (Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage)

  • 최연석;이인환
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

기체 유량 측정에서 몬테 카를로 모사를 이용한 측정불확도 평가 (Uncertainty Assessment Using Monte Carlo Simulation in Gas Flow Measurement)

  • 이대성;양인영;김춘택;양수석
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1758-1765
    • /
    • 2003
  • Monte Carlo simulation(MC) method was used as an uncertainty assessment tool for gas flow measurement in this paper. Uncertainty sources for gas flow measurement were analyzed, and probability distribution characteristics of each source were discussed. Detailed MC methodology was described including the effect of the number of simulation. The uncertainty result was compared with that of the conventional sensitivity coefficient method, and it was revealed that the results were different from each other for this particular gas flow measurement case of which the modelling equation was nonlinear. The MC was comparatively simple, convenient and accurate as an uncertainty assessment method, especially in cases of complex, nonlinear measurement modelling equations. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the measurement.

Small-Gap을 이용한 가스차단기에서의 열가스 속도측정에 관한 연구 (A Study on A Hot Gas Velocity Measurement in GCB Using Small-Gap)

  • 김홍규;송기동;박경엽;홍정표;정진교
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권3호
    • /
    • pp.155-158
    • /
    • 2006
  • $SF_6$ gas circuit breakers we widely used for short circuit current interruption in EHV or UHV power system. For a $SF_6$ gas circuit breaker development, the hot gas velocity measurement is necessary during $SF_6$ gas circuit breaker's trip operation. Small-gap flashover characteristics are used for this hot gas velocity measurement. This study sho was the hot gas velocity measurement results during $SF_6$ gas circuit breaker' trip operation.

운행 휘발유 자동차의 배출가스검사 시스템 비교 (Comparision in Emission Inspection System of a Gasoline Vehicle in Service)

  • 오상엽;박원덕
    • 한국자동차공학회논문집
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2014
  • In the most of a nation, the safety and emission gas inspection system of a vehicle in service have been conducted with the most compatible inspection system according to its real environmental situation. Especially, the state of vehicle emission gas is measured by advanced emission gas inspection equipment. It has the problem that the decrease effect of an environmental pollution matter is not calculated by weight percent measurement type equipment. Therefore, in this study, the correlations for the results of emission gas measurement are analyzed by comparing a weight percent measurement type (IDLE+ASM2525 mode) and an advanced mass measurement type (IM240 mode). As the result, the selectivity of an emission gas by IM240 mode is higher than that by IDLE+ASM2525 mode. In the future, therefore, the introduction of IM240 mode and a mass measurement type equipment are necessary. Also, we need to prepare a vehicle emission gas inspection system for introducing IM240 mode.

돈사내 암모니아가스 계측시스템 개발 (Development of a Measurement System for Ammonia Gas in Swine Housing)

  • 방승훈;장동일;장홍희;임영일
    • Journal of Biosystems Engineering
    • /
    • 제23권4호
    • /
    • pp.359-364
    • /
    • 1998
  • A PC based measurement system was developed and it consisted of ammonia sensor(TS-1000), AMP & MUX Board, A/D Converter, and personal computer. The results obtained from the study are summarized as follows : 1. The relationship of outputs(V) of ammonia sensor(AS) and concentrations(ppm) of ammonia gas was analyzed by the linear regression analysis and the output values were very accurate when compared with standard ammonia gas. 2. The test results showed that the performance of ammonia gas sensor was not 31B3c1e4 by temperatures and humidities 3. The developed ammonia gas measurement system was proved to be practically uesful for measuring concentrations of ammonia gas in pig housing.

  • PDF

무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템 (NDIR Multi-Gas Measurement System for Air Quality based on Wireless Sensor Network)

  • 백승현;이준영;정상우;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제11권5호
    • /
    • pp.299-304
    • /
    • 2016
  • As public interest in air quality and environment problem is increasing, many researches are being carried out the gas measurement system. Especially, Non-dispersive infrared (NDIR) measurements using Beer-Lambert gas sensing principle with very high selectivity and long life time are noted for reliable method. It is possible to detect various gases such as carbon dioxide (CO2), carbon monoxide (CO), and nitrogen dioxide (NO2), but many researches are mostly concentrated on CO2 sensor. The multi-gas measuring instrument is high price and unwieldy, therefore it is not suitable for wide area required numerous instrument. So we study the NDIR multi-gas measurement system for air quality based on wireless sensor network, and experiment the realized measurement system.

아세톤 PLIF를 이용한 가스터빈 연소기 버너 출구 연료분포의 정량적 측정 (Quantitative Acetone PLIF Measurement of Fuel Distribution in a Gas Turbine Combustor Burner)

  • 전우진;김형모;이강엽;양수석
    • 한국연소학회지
    • /
    • 제15권4호
    • /
    • pp.43-52
    • /
    • 2010
  • A non-intrusive measurement, Planar Laser Induced Fluorescence was employed to visualize and measure the fuel distribution of the non-reacting field at the burner exit of gas turbine combustor. Measurement techniques, image processing method and quantification procedure were presented. Also, concentration measurement with gas analyzer was carried out to verify the propriety of PLIF result. The PLIF result coincides well with gas analyzer measurement result. PLIF test result for several other conditions are mentioned as well.

수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구 (A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station)

  • 최진영;이화영;임상식;이재훈
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.