• Title/Summary/Keyword: gas generation rate

Search Result 356, Processing Time 0.033 seconds

Experimental Study on Thermoelectric Generator Performance for Waste Heat Recovery in Vehicles (자동차 배기폐열 회수용 열전발전 시스템의 성능에 관한 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.287-293
    • /
    • 2014
  • Internal combustion engines release 30~40% of the energy from fossil fuels into the atmosphere in the form of exhaust gases. By utilizing this waste heat, plenty of energy can be conserved in the auto industry. Thermoelectric generation is one way of transforming the energy from engine's exhaust gases into electricity in a vehicle. The thermoelectric generators located on the exhaust pipe have been developed for vehicle applications. Different experiments with thermoelectric generators have been conducted under various test conditions as following examples: hot gas temperature, hot gas mass flow rate, coolant temperature, and coolant mass flow rate. The experimental results have shown that the generated electrical power increases significantly with the temperature difference between the hot and the cold side of the thermoelectric generator and the gas flow rate of the hot-side heat exchanger. In addition, the gas temperature of the hot-side heat exchanger decreases with the length of the thermoelectric generator, especially at a low gas flow rate.

The Hydrogen Generation's Characteristics using Plasma Reactor of Multi-needle Electrode Type (다중침전극형 플라즈마 반응기를 이용한 수소발생 특성)

  • Park, Jae-Yoon;Kim, Jong-Seok;Jung, Jang-Gun;Goh, Hee-Seok;Park, Sang-Hyun;Lee, Hyun-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1246-1251
    • /
    • 2004
  • This paper is investigated about the effect of carrier gas type and the humidity for generating hydrogen gas. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 3500 ppm. In the experimental result of generating hydrogen gas by non-thermal plasma reactor, the rate of generating hydrogen gas is different with what kind of carrier gas is. We used two types of carrier gas, such as $N_2$ and He. $N_2$ as carrier gas is more efficient to generate hydrogen gas than He because $N_2$ is reacted with $O_2$, which is made from water dissociation. In comparison with water droplet by humidifier and without water droplet by humidifier, the generation of hydrogen gas is decreased in case of water droplet by humidifier. That is the result that the energy for water dissociation is reduced on water surface because a part of plasma energy is absorbed at the small water molecular produced from humidifier.

Potential of gas generation and natural gas hydrate formation in the near seafloor sediment of the Ulleung Basin (울릉분지 천부 퇴적층에서의 가스 생성과 천연가스 하이드레이트 형성 잠재력)

  • Ryu, Byong-Jae;Lee, Young-Joo;Kim, Ji-Hoon;Kim, Il-Soo;Park, Myong-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.419-423
    • /
    • 2006
  • Basic studies on natural gas hydrates in the East Sea were been carried out by the Korea Institute of Geoscience and Mineral Resources (KIGAM) from 2000 to 2004 involving 2D multichannel seismic lines and piston coring. 27 piston cores recovered from the deed-water Ulleung Basin of the East Sea were analyzed in this study. In piston cores cracks generally developed parallel to bedding suggest significant gas content. The core analyses showed high total organic carbon (TOC) content, sedimentation rate and heat flow of sediments. The cores recovered from the southern study area show also high residual hydrocarbon gas concentrations for the formation of natural gas hydrates. This study indicates that there is the potential for the generation of biogenic gas and the formation of natural gas hydrates in the near seafloor sediments of the study area.

  • PDF

Assessment of Landfill Gas Generation - A Case Study of Cheongju Megalo Landfill (매립지 가스 발생량 평가 - 청주권 광역생활폐기물 매립장 사례연구)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.5
    • /
    • pp.321-330
    • /
    • 2008
  • Methane is a potent greenhouse gas and methane emissions from landfills have been linked to global warming. In this study, LandGEM (Landfill Gas Emission Model) was applied to predict landfill gas quantity over time, and then this result was compared with the data surveyed on the site, Cheongju Megalo Landfill. LandGEM allows the input of site-specific values for methane generation rate (k) and potential methane generation capacity $L_o$, but in this study, k value of 0.05/yr and $L_o$ value of $170m^3/Mg$ were considered to be most appropriate for reflecting non-arid temperate region conventional landfilling, Cheongju Megalo Landfill. High discrepancies between the surveyed data and the predicted data about landfill gas seems to be derived from insufficient compaction of daily soil-cover, inefficient recovery of landfill gas and banning of direct landfilling of food garbage waste in 2005. This study can be used for dissemination of information and increasing awareness about the benefits of recovering and utilizing LFG (landfill gas) and mitigating greenhouse gas emissions.

Effects of Different Coal Type on Gasification Characteristics (Pilot 규모 석탄 가스화기에서의 탄종별 가스화성능 특성)

  • Park, Se-Ik;Lee, Joon-Won;Seo, Hea-Kyung
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.5
    • /
    • pp.470-477
    • /
    • 2010
  • The IGCC (Integrated gasification combined cycle) is known for one of the highest efficiency and the lowest emitting coal fueled power generating technologies. As the core technology of this system is the gasifier to make the efficiency and the continuous operation time increase, the research about different coal's gasification has been conducted. Our research group had set-up the coal gasifier for the pilot test to study the effect of different coals-Shenhua and Adaro coal- on gasification characteristics. Gasification conditions like temperature and pressure were controlled at a fixed condition and coal feed rate was also controlled 30 kg/h to retain the constant experimental condition. Through this study we found effects of coal composition and $O_2$/coal ratio on the cold gas efficiency, carbon conversion rate. The compounds of coal like carbon and ash make the performance of gasifier change. And carbon conversion rate was decreased with reduced $O_2$/coal ratio. The optical $O_2$/coal ratio is 0.8 for the highest cold gas efficiency approximately. At those operating conditions, the higher coal has the C/H ratio, the lower syn-gas has the $H_2$/CO ratio.

Stabilization of Industrial Wastes Landfill using Lab-lysimeter (모형매립조를 이용한 산업폐기물 매립지의 안정화 조사 기초 연구)

  • 박동일;최석규;홍종순;장인용
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.9-18
    • /
    • 1998
  • An experimental research was conducted to establish primary data for the stabilization assessment of industrial wastes landfill with analysis of waste components and investigation of leachate and gas generation, using three sets of lysimeter as experimental apparatus. Comparing results of lysimeter from data of landfill, it is suggested that lysimeter of this study can be used to accomplish the stabilization assessment of the real landfill site. Moisture content was lower as landfill period was older and combustible component was the highest in lysimeter C. The C/N ratio of waste was 7.4~14.4 and, with the elemental analysis, the theoretical gas generation rate based on the modified Buswell equation was 0.47~0.49 $m^3/kg-dry$ waste in lysimeter C. Considering the C/N ratio of leachate, it is concluded that the addition of carbon source is needed to biodegrade leachate hereafter. Gas generation rate($m^3/kg-dry$ waste) from lysimeter A, B and C was 0.0009, 0.014 and 0.0067, respectively, and different from each other according to the landfill period of wastes. The results in this study show that the biodegradation of microorganism for stabilization of landfill was inhibited and more activated in acidogenic step than in methanogenic of anaerobic degradation.

  • PDF

A Study on the Operational Optimization of Turbo-Expander Pressure Reduction System to the Natural Gas Flow Rates (천연가스 유량변화에 따른 터보팽창기 감압시스템 운전 최적화에 관한 연구)

  • Yoo, Han Bit;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.72-79
    • /
    • 2015
  • Electricity can be generated when the natural gas passes through a turbo-expander pressure reduction system at natural gas pressure reduction stations. Efficiency of the turbo-expander depends on the ratio of the natural gas flow rates to the design flow rate of the turbo-expander. Therefore, the optimal conditions for the operation of the pressure reduction system can be determined by controlling the natural gas flow rates. In this study, we have calculated the electric energy generation depending on the natural gas flow rates at the two low-pressure reduction stations when the pressure of the natural gas is reduced from 17.5 bar to 8.5 bar and have found the optimal conditions for the turbo-expander pressure reduction system through the comparison with the calculation results. The turbo-expander generates the electric power efficiently for the high natural gas flow rates which variations are slight. The determined design flow rate of the turbo-expander has the highest coverage of the natural gas flow rates. The electricity generation is calculated as much as 9 MW(B station) and 12 MW(D station) at each pressure reduction station.

Ozone Generation and NO Gas Removal Characteristics a Hybrid Discharge Type Ozonizer (복합방전형 오존발생기의 오존생성 및 NO 가스 제거특성)

  • Song, Hyun-Jig;Lee, Sang-Seock;Shin, Yong-Chul;Kim, Min-Huei;Park, Chan-Gyu;Lee, Kwang-Sik;Im, Chang-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.278-280
    • /
    • 2006
  • A hybrid discharge type ozonizer, which is superposed silent and surface discharges, has been designed and manufactured to apply for Nitrogen Oxides(NO) gas removal. The ozonizer consists of three electrodes, and is classified three types of ozonizer by changing applied voltage. Investigation was carried out variance with the flow rate of supplied oxygen gas, discharge power and the sorts of superposed discharge type ozonizer. Moreover, $NO(1200[ppm])/N_2$ gas removal investigation was also conducted to apply for environment improvement field. Two kinds of NO gas removal investigations were conducted. It distinguishes the investigations into NO gas reaction method. According to these studies, maximum removal rate of 100[%] in NO gas was obtained, and 8334[ppm] and 3249[mg/h] of maximum ozone concentration and generation were also obtained respectively.

  • PDF

The effect of vibration of the water surface for hydrogen gas generation by plasma electrical discharge (비열플라즈마에 의한 수소가스발생에 미치는 수표면 진통효과)

  • Kim, Jong-Seog;Park, Jae-Yoon;Jung, Jang-Gun;Kim, Tae-Yong;Lee, Jae-Dong;Koh, Hee-Seog;Lee, Hyun-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.115-119
    • /
    • 2004
  • This paper is investigated about the effect of vibration of the water surface for hydrogen gas generation by non-thermal plasma. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 6.8[ml/sec]. Although the generation of hydrogen gas is increased with elevating time, it is saturated after specific time due to the volume of reactor and the saturation of taylor cone.

  • PDF

A Study on the Optimal Condition for Minimizing Spatter Generation at GMAW Robot (GMAW Robot에서 Spatter최소 발생 조건에 관한 연구)

  • Kim, Han-Sik;Han, Shin-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.83-91
    • /
    • 2008
  • GMAW(Gas Metal Arc Welding) processes are usually used in industrial side in order to get its high productivity. But those are only adopted in the semi-automated welding equipment because of a lot of welding spatters. Many industrial robot actually percents from being engaged in the welding processes. The welding spatter problem of causes blocking them being a fully automated welding process.This study was carried out to investigate the optimal conditions for minimizing welding spatter generation at GMAW robot. The spatter can be significantly reduced below 2% of welding spatter generation at the following conditions ; First, below 18V at the wire-feed rate 2.0mm/min Second, below 23V at the wire-feed rate 3.6mm/min Third, below 24V at the wire-feed rate 5.5mm/min.

  • PDF