• Title/Summary/Keyword: gas film

Search Result 2,504, Processing Time 0.031 seconds

Analyze of I-V Characteristics and Amorphous Sturcture by XRD Patterns (XRD 패턴에 의한 비정질구조와 I-V 특성분석)

  • Oh, Teresa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.16-19
    • /
    • 2019
  • A thinner film has superior electrical properties and a better amorphous structure. Amorphous structures can be effective in improving conductivity through a depletion effect. Research is needed on the Schottky contact, where potential barriers are formed, as a way to identify these characteristics. $SiO_2/SnO_2$ thin films were prepared to examine the amorphous structure and Schottky contact, $SiO_2$ thin films were prepared using Ar = 20 sccm. $SnO_2$ thin films were deposited using mixed gas with a flow rate of argon and oxygen at 20 sccm, and $SnO_2$ thin films were added by magnetron sputtering and treated at $100^{\circ}C$ and $150^{\circ}C$. To identify the conditions under which the amorphous structure was constructed, the XRD patterns were investigated and C-V and I-V measurements were taken to make Al electrodes and perform electrical analysis. The depletion layer was formed by the recombination of electrons and holes through the heat treatment process. $SiO_2/SnO_2$ thin films confirmed that the pores were well formed when heat treated at $100^{\circ}C$ and an electric current was applied over the micro area. An amorphous $SiO_2/SnO_2$ thin film with heat treatment at $100^{\circ}C$ showed no reflection at $33^{\circ}\;2{\theta}$ in the XRD pattern, and a reflection at $44^{\circ}2\;{\theta}$. The macroscopic view (-30 V

Corrosion Characteristics by CCPP Control in Simulated Distribution System (CCPP 조절에 따른 모의 상수관로의 부식특성에 관한 연구)

  • Kim, Do-Hwan;Lee, Jae-In;Lee, Ji-Hyung;Han, Dong-Yueb;Kim, Dong-Youn;Hong, Soon-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1249-1256
    • /
    • 2005
  • This study was performed to investigate the efficiency of the corrosion prevention in the simulated distribution system using CCPP(Calcium Carbonate Precipitation Potential) as the anti-corrosive index by adjusting pH, total dissolved solids, alkalinity and calcium hardness in the water treatment pilot process. The materials of the simulated distribution system(SDS) were equiped with same materials of real field water distribution system. CCPP concentrations controlled by $Ca(OH)_2$, $CO_2$ gas and $Na_2CO_3$ in the simulated distribution system and uncontrolled by the chemicals in the general water distribution system were average 0.61 mg/L and -7.77 mg/L. The concentrations of heavy metals like Fe, Zn, Cu ions in effluent water of the simulated distribution system controlled with water quality were decreased rather than the general water distribution system uncontrolled with water quality. In simulated distribution system(SDS), corrosion prevention film formed by CCPP control was observed that scale was come into forming six months later and it was formed into density as time goes on. We were analyzed XRD(X-ray diffraction) for investigating component of crystal compounds and structure for galvanized steel pipe(15 mm). Finding on analysis, scale was compounded to $Zn_4CO_3(OH)_6{\cdot}H_2O$ (Zinc Carbonate Hydroxide Hydrate) after ten months late, and it was compounded on $CaCO_3$(Calcium Carbonate) and $ZnCO_3$(Smithsonite) after nineteen months later.

Properties of Indium Tin Oxide Thin Films According to Oxygen Flow Rates by γ-FIB System (γ-FIB 시스템을 이용한 산소 유량 변화에 따른 산화인듐주석 박막의 특성 연구)

  • Kim, D.H.;Son, C.H.;Yun, M.S.;Lee, K.A.;Jo, T.H.;Seo, I.W.;Uhm, H.S.;Kim, I.T.;Choi, E.H.;Cho, G.S.;Kwon, G.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.333-341
    • /
    • 2012
  • Indium Tin Oxide (ITO) thin films were prepared by RF magnetron sputtering with different flow rates of $O_2$ gas from 0 to 12 sccm. Electrical and optical properties of these films were characterized and analyzed. ITO deposited on soda lime glass and RF power was 2 kW, frequency was 13.56 MHz, and working pressure was $1.0{\times}10^{-3}$ Torr, Ar gas was fixed at 1,000 sccm. The transmittance was measured at 300~1,100 nm ranges by using Photovoltaic analysis system. Electrical properties were measured by Hall measurement system. ITO thin films surface were measured by Scanning electron microscope. Atomic force microscope surface roughness scan for ITO thin films. ITO thin films secondary electron emission coefficient(${\gamma}$) was measured by ${\gamma}$-Focused ion beam. The resistivity is about $2.4{\times}10^{-4}{\Omega}{\cdot}cm$ and the weighted average transmittance is about 84.93% at 3 sccm oxygen flow rate. Also, we investigated Work-function of ITO thin films by using Auger neutralization mechanism according to secondary electron emission coefficient(${\gamma}$) values. We confirmed secondary electron emission peak at 3 sccm oxygen flow rate.

Development of Questionnaire Measuring Quality of Life in Pneumoconioses (진폐증 환자의 삶의 질 설문지 개발)

  • Baak, Young-Mann;Ahn, Byoung-Yong;Mun, Je-Hyeok;Jeong, Jin-Sook;Kim, Ji-Hong;Kim, Kyoung-Ah;Lim, Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.54-66
    • /
    • 2000
  • Background: Pneumoconiosis, like other chronic respiratory diseases, is essentially incurable and, for many, progressive. While improved survival time is an important aim of treatment, there is growing recognition that for some people, improving the quality of life is more important than extending the length of life. Currently the measurement of the quality of life is used to assess the efficacy of therapeutic agents. Methods: Sixty-three pnemoconiotics who were admitted to St. Mary's Hospital between April and August 1999 were interviewed using COOP charts, Chronic Respiratory Questionnaire(CRQ) and Pneumoconiotic Respiratory Questionnaire(PRQ), a newly developed questionnaire concerning clinical and socioeconomic features of pneumoconiotics. Also, ILO classification of the chest film, pulmonary function test, and arterial blood gas analysis of the patients were evaluated. The scores between Industrial Accident Compensation Insurance(IACI) covered and uncovered patients and between clinically stable and unstable patients were compared. Results: Domains of CRQ and PRQ showed a high internal consistency reliability($\alpha$=0.86-0.89, 0.77-0.81) except the dyspnea domain($\alpha$=0.63) of CRQ. The scores on the CRQ and PRQ showed statistically significant correlations with the results of COOP charts, pulmonary function test and arterial blood gas analysis. The dyspnea domain and social activity domain of the PRQ showed significant difference between IACI covered and uncovered patients and between clinically stable and unstable patients. Conclusion : Korean translation of the Chronic Respiratory Questionnaire and the newly developed Pneumoconiotic Respiratory Questionnaire are reliable and valid methods and are likely to be useful in measuring the quality of life in patients with the chronic respiratory disease including pneumoconiosis.

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Effect of Precooling Treatments on the Storability of Chicon during MA Storage (예냉 처리가 치콘의 MA 저장성에 미치는 영향)

  • Jung, Hyun-Jin;Seo, Hyun-Taek;Choi, In-Lee;Yoo, Tae-Jong;Son, Jin-Sung;Won, Jae-Hee;Kim, Il-Seop;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.360-365
    • /
    • 2010
  • The effects of precooling treatments on the storability of chicon were investigated during modified atmosphere (MA) storage. The forced air cooling showed faster precooling rate that reduced the internal temperature of chicon to $2{\pm}1^{\circ}C$, and the precooling time of forced air cooling was 1/6 of room cooling. The half cooling time was 3 hr 21 min in room cooling and 1 hr 17 min in forced air cooling. Weight loss was less than 0.5% in all treatments both $5^{\circ}C$ and $10^{\circ}C$ MA storage and maintained higher in forced air cooling treatment. The concentration of carbon dioxide, oxygen, and ethylene of $50{\mu}m$ ceramic film packages were observed higher at $10^{\circ}C$ than $5^{\circ}C$. The precooling effect on respiration reduction was not shown at $5^{\circ}C$, but appeared that the gas concentration of precooling treatments showed less carbon dioxide and higher oxygen than non precooling treatment by 9 days after $10^{\circ}C$ storage. Ethylene concentration of precooling treatments showed lower than non precooling treatment until 3 days both $5^{\circ}C$ and $10^{\circ}C$ MA storage. Precooling showed the effect on maintaining visual quality of chicon both $5^{\circ}C$ and $10^{\circ}C$ MA storage. However, the forced air cooling that showed faster precooling rate did not appeared more precooling effect on the visual quality than room cooling because the fast air flow (6.0 m/sec) of forced air cooling hit directly on chicon outer leaves and might cause physical damage to chicon. Although the forced air cooling showed the effect on maintaining quality of chicon, but additional studies should be needed that investigated proper air flow rate and cooling box structure can prevent physical damage by air flow.

An Comparison of Storability of Several Cultivars Chicon Grown in Different Regions (품종과 재배지역에 따른 치콘의 저장성 비교)

  • Kang, Ho-Min;Kim, Hyuk-Su;Seo, Hyun-Taek;Won, Jae-Hee
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.291-296
    • /
    • 2009
  • This study was conducted to compare the storability of 6 chicory cultivars for producing chicon; 'Vintor', 'Focus', 'Metafora', 'Kibora', 'Nobus', and 'Redoria Red' grown in 2 regions: Chuncheon (plain region) and Pyeongchang (high land region). Chicons were produced from chicory roots that grown for 120days and then stored for over 120days at $2^{\circ}C$ and 90% of RH conditions. To produce chicon, chicory root was forced at $18^{\circ}C$ for 22days with suppling the nutrient solution ($KNO_30.54g{\cdot}L^{-1}$, $Ca(NO_3)_2\;1.02g{\cdot}L^{-1}$, $MgSO_4\;0.36g{\cdot}L^{-1}$, $KH_2PO_4\;0.21g{\cdot}L^{-1}$, $K_2SO_4\;0.10g{\cdot}L^{-1}$, pH 7.0). Chicons produced from 6 different chicory cultivars packed with $25{\mu}m$ ceramic film and stored for 25days at $8^{\circ}C$. The fresh weight of chicon in MAP was maintained to 99.5% of pre-storage weight. The fresh weight of 'Redoria Red' was lowest in all cultivars, and that of Chuncheon region cultivated treatment was lower than Pyeongchang treatment. The $CO_2$ and $O_2$ concentration in chicon MAP were 2% and $10{\sim}17%$. There were not significantly different among cultivars and between regions, although 'Redoria Red' cultivar showed highest $CO_2$ and lowest $O_2$ concentrations. The ethylene concentration in chicon MAP was $1.0{\mu}{\iota}{\cdot}{\iota}^{-1}$ and also didn't show any significant difference among all treatments. Chicon detoriorated visual quality with appearing russet spotting that result from ethylene gas. The visual quality of 'Redoria Red' cultivar decreased faster than the other cultivars. 'Metafora', 'Focus', and 'Kibora' maintained higher firmness of their leaf than the others, and the firmness was higher grown in Pyeongchang region cultivated treatments than in Chuncheon region.

Effect of Different Temperatures on the storability of Salsola komarovi Iljin and Suaeda maritima L. Dum. in MA Storage (저장온도가 MA 저장한 수송나물(Salsola komarovi Iljin)과 해홍나물(Suaeda maritima L. Dum.)의 MA저장성에 미치는 영향)

  • Yoo, Tae-Jong;Kim, Il-Seop;Kang, Wie-Soo;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.19 no.3
    • /
    • pp.159-164
    • /
    • 2010
  • This study was carried out to compare the storability of Salsola komarovi Iljin and Suaeda maritima L. Dum which stored at different storage temperatures in MA storage. These plants that had grown in greenhouse packed with $50\;{\mu}m$ ceramic film and then stored in $2^{\circ}C$, $10^{\circ}C$, and $25^{\circ}C$ temperature. The fresh weight loss both plants was less than 1% in all temperature treatments. The highest fresh weight loss showed at $25^{\circ}C$ among storage temperature treatments in Salsola komarovi Iljin between plants. The highest carbon dioxide contents in package showed at $25^{\circ}C$ among storage temperature treatments in Salsola komarovi Iljin between plants, and at $2^{\circ}C$ and $10^{\circ}C$ temperature treatments remained less than 1%. Oxygen contents in package both plants showed the highest level at $2^{\circ}C$ temperature treatment, but Salsola komarovi Iljin showed less oxygen contents than Suaeda maritima L. Dum. Although there was no significant difference ethylene contents in package between $2^{\circ}C$ and $10^{\circ}C$ temperature treatments, the higher showed in $10^{\circ}C$ than $2^{\circ}C$ temperature treatments. The ethylene contents in package both plants were roughly $20\;{\mu}L{\cdot}L^{-1}$ and the higher was in Suaeda maritima L. Dum than Salsola komarovi Iljin at $2^{\circ}C$. As increasing the storage temperature, the contents of carbon dioxide and ethylene in package also increased in both plants. The carbon dioxide and ethylene contents of Salsola komarovi Iljin showed a significant difference between $2^{\circ}C$ and $10^{\circ}C$ temperature treatments, but Suaeda maritima L. Dum did not show. The shelf life of Salsola komarovi Iljin based on visual quality was 14 days at $2^{\circ}C$ temperature treatment and 7.5 days at $10^{\circ}C$ temperature treatment. However, the shelf life of Suaeda maritima L. Dum did not show a significant difference between $2^{\circ}C$ temperature treatment that was 11 days, and $10^{\circ}C$ temperature treatment that was 9.5 days. Considering visual quality and gas contents in package, Suaeda maritima L. Dum might appear chilling injury at $2^{\circ}C$ temperature treatment.

Effect of Application of Rice Bran Extract on Quality of Agaricus bisporus during Storage (쌀겨추출물을 적용한 양송이의 저장 중 품질 변화)

  • Park, Hye Jin;Kim, Gun-Hee
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.834-844
    • /
    • 2014
  • Postharvest browning of mushroom (Agaricus bisporus) reduces the shelf life of harvested mushrooms. Here, mushrooms were dipped in various solutions (distilled water; DW, 0.25% rice bran extract; RB, 0.1% ascorbic acid; AA, RB + AA) for 3 min. After air-drying at room temperature, the dipped mushrooms were packaged in a polypropylene (PP) films and stored at 4 or $15^{\circ}C$. The quality changes of mushrooms were measured in terms of color, gas composition, firmness, and sensory evaluation during storage. Rice bran extract was measured for total polyphenol content, total flavonoid content, DPPH, ABTS radical scavenging, chelating activity and PPO inhibition activity. No difference in firmness were found in the mushroom samples regardless of dipping solution or storage temperature. At both 4 and $15^{\circ}C$ storage temperatures, RB + AA solution-dipped samples showed the highest L value and lowest delta E value. During the storage period, sensory evaluation showed that overall acceptability of mushrooms treated with RB and RB + AA solution was higher than that of the untreated mushrooms. Total polyphenol and flavonoid contents of 0.25% rice bran extract were $36.42mg\;GAE{\cdot}g^{-1}$ and $4.85mg\;QE{\cdot}g^{-1}$, respectively. The DPPH and ABTS radical scavenging activity of 0.1% ascorbic acid was higher than that of 0.25% rice bran extract. The highest copper ($Cu^{2+}$) chelating activity was found in the 0.25% rice bran extract. The PPO inhibition activity of 0.1% ascorbic acid was higher than that of 0.25% rice bran extract. Our results suggest that 0.25% rice bran extract with 0.1% ascorbic acid is effective anti-browning agent for maintaining quality of Agaricus bisporus during storage.