• Title/Summary/Keyword: gas delivery

Search Result 94, Processing Time 0.191 seconds

Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners (공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구)

  • Kim, Hak-Joon;Han, Bangwoo;Kim, Yong-Jin;Cha, Sung-Il
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

LFG Utilization in Hong Kong (Case study of the Shuen Wan and Urban Landfills)

  • Lloyd, Bryce;Chan, Louis;Nardelli, Ray;Sullivan, Kevin
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2001.05b
    • /
    • pp.85-91
    • /
    • 2001
  • This paper provides a case study of landfill gas (LFG) utilization fer direct use as process fuel, and for electrical power generation at restored landfills in the Hong Kong Special Administrative Region of China (HKSAR). The paper specifically covers the LFG utilization schemes, which are required under landfill restoration contracts at the Shuen Wan and Urban Landfills. These contracts provide for the restoration and aftercare of six landfills, and are administered by the Environmental Protection Department (EPD) of the Hong Kong Government. The LFG utilization scheme at the Shuen Wan Landfill incorporates the direct use of LFG by compressing and dehumidifying the LFG prior to conveyance through a 1.6-kilometer (1-mile) pipeline. The pipeline provides an alternate fuel source to naphtha during process heating for gas production at the Tai Po Gas Production Plant of the Hong Kong and China Gas Limited (HKCC). The LFG utilization scheme at the Jordan Valley Landfill (one of the Urban Landfills) beneficially uses the LFG as fuel for electrical power generation with reciprocating internal combustion engines. The LFG is compressed, cooled, and filtered prior to delivery to two engine/generator sets. This system provides power to operate the leachate pre-treatment plant, which processes leachate from all of the Urban Landfill sites. The case study will examine the technical and non-technical considerations, including harriers, for developing, designing and implementing the LFG utilization projects in Hong Kong. Specific regulatory considerations and external governmental agency approvals are discussed, including the requirement to register as a gas-producing utility. While the paper focuses on LFG utilization applications in Hong Kong, many of the considerations discussed are also applicable to development of LFG utilization in other regions of Asia.

  • PDF

The Isoflurane Concentration of Precision Vaporizer Goldman Vaporizer According to Room Temperature and Carrier Gas Flow Rate (온도 및 유량에 따른 흡입 마취제 전용 기화기와 Goldman 기화기의 isoflurane 농도 변화)

  • 김성미;장화석;이정선;최치봉;임희란;최준철;김휘율
    • Journal of Veterinary Clinics
    • /
    • v.21 no.3
    • /
    • pp.270-275
    • /
    • 2004
  • Anesthetic machines may be equipped with either a precision or nonprecision vaporizer. A precision vaporizer is designed to deliver an exact concentration of anesthetic agent. Goldman vaporizer is a low-flow, closed-circle circuit with a low resistance vaporizer, in circuit. Vaporizers used within circle system(VIC) are not usually temperature compensated and this is generally thought to be a disadvantage. As the volatile agent is vaporized, heat is extracted from the liquid and temperature decreases. This cooling of the liquid leads to a decrease in concentration of the anaesthetic agent delivered by the vaporizer. The purpose of this study is to examine the mechanical consistency of the delivery of isoflurane from Goldman vaporizer and precision vaporizer at various gas flow rates and temperatures. And we first studied isoflurane concentration according to room temperature changes delivered by a Goldman vaporizer and precision vaporizer using different gas flow. The room temperature of $15^{\circ}C,$ $20^{\circ}C,$ $28^{\circ}C$ and fresh gas flow rates of 0.5, 1.0, 1.5, 2.0, 3.0 l/min were used. The inspired agent concentration was measured using a Datex-Ohmeda multigas analyzer. As rose in room temperature, the isoflurane concentration of precision vaporizer approximated the dial setting. On the other hand, at a dial setting concentration of 5.0 percent the delivered isoflurane concentration of precision vaporizer was more than the dial setting in high temperature. The isoflurane concentration of precision vaporizer remained constant despite the increase in temperature. The isoflurane concentration of Goldman vaporizer was increased with rise in room temperature and decreased with rise in gas flow.

A Study on the Monitoring Criteria of Disaster Signs for Early-warning System based on Multiple Hazardous Gas Sensor (복합 유해 가스 센서 기반의 조기 경보 시스템을 위한 재난 전조 감시 기준에 관한 연구)

  • Han, Kyusang;Park, Sosoon;Yoon, En Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.28-35
    • /
    • 2013
  • The number of large and complex buildings is growing and they are usually concentrated in metropolitan cities. There is a possibility in such buildings that a small accident can expand to a massive disaster since their scale and complexity. To deal with this issue, a research on gas sensors which can detect multiple gases and early-warning systems has been conducted. Proper criteria or standards are necessary for effective application and operation of such sensor-based disaster monitoring system. In this study, we have proposed the alarm criteria of concentration of hazardous gases for the detection and the alarm release. For each alarm level, systematic disaster response plans consist of responsive actions and information delivery have been prepared. These disaster monitoring criteria can help the detection of hazardous gas-related disaster in the early stage of accident and the provision of appropriate emergency responses.

Characteristics of (Ba,Sr)RuO$_3$Bottom Electrodes by Liquid Delivery Metalorganic Chemical Vapor Deposition (액체 운반 유기 금속 화학 기상 증착법에 의한 $(Ba,Sr)RuO_3$ 하부전극의 특성)

  • Choe, Eun-Seok;Yun, Sun-Gil
    • Korean Journal of Materials Research
    • /
    • v.11 no.11
    • /
    • pp.997-1000
    • /
    • 2001
  • Conducting perovskite oxide, $(Ba,Sr)RuO_3(BSR)$, which has many advantages for $(Ba,Sr)TiO_3(BST)$ due to their similarity in crystal structure, lattice constant and chemical composition, was prepared on n-type Si (100) by liquid delivery metalorganic chemical vapor deposition(LDMOCVD). The deposition characteristics of BSR were controlled by gas-phase mass-transfer in the experiment. The BSR films deposited at 50$0^{\circ}C$ and oxygen flow rate of 100 sccm(standard cc/min) showed an average roughness of 22 $\AA$and resistivity of 810 $\mu$$\Omega$-cm. The roughness of BSR films with oxygen flow rate showed a close relationship with the resistivity of films. BSR (110) peak shifted toward lower Bragg angle with increase of x in the$(Ba_x,Sr_{1-x})TiO_3$. The resistivity of BSR films increased from 810 to 924 $\mu$$\Omega$-cm with increase of Ba content(x).

  • PDF

A Study for Regulating Flow Fluctuation and Preventing Backflow of Peristaltic Pump (연동펌프의 유량맥동 조절과 역류현상을 방지하는 장치에 대한 연구)

  • Jeong, Yoo-seok;Lee, Cheol-Soo;Lee, Tae-Kyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.5
    • /
    • pp.28-34
    • /
    • 2016
  • Though a peristaltic pump is a crucial element in miniaturized drug delivery systems, it has some intrinsic disadvantages such as backflow and flow fluctuation. To overcome these limitation, we have developed valve-less peristaltic pump system including orifice and stagnation chamber. we measured flow rate to investigate the performance of rotary peristaltic pump with three rollers and an elastomeric tube pumping a viscous fluid. The flow fluctuations and the backflow happen as a result from the disengagement of the contact interaction between the rollers and the tubes. Stagnation chamber installed in front of orifice plate was composed of rubber tube and gas chamber. By changing orifice hole diameter with stagnation chamber flow rate and pressure in the tube was regulated. The obtained maximum reduction ratio of flow fluctuation is 96.79%.

Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor (흐름주입식 바이오센서용 기질용액 자동희석 장치 개발)

  • Song, D.B.;Jung, H.S.;Jung, D.H.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

A Study on Performance Characteristics of the Developed Fuel Pump for a Single-cylinder Four-stroke Agricultural Diesel Engine (단기통 4행정 농용 디젤기관의 개발 연료펌프 성능특성에 관한 연구)

  • Bae, Myung-whan;Lee, Sang-hae;Jung, Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.756-761
    • /
    • 2016
  • The objective of this study is to design and manufacture a fuel pump with the plunger diameter of 4 mm and stroke of 7 mm that can be mounted in a small single-cylinder four-stroke agricultural diesel engine, and to investigate the performance characteristics of the pump. The combustion pressure in a cylinder was reproduced by forming the back pressure of 1, 6, 11, 16 and 21 bar with a nitrogen gas in the home-manufactured modeling cylinder. In the experiment, the discharge pressure was measured at the spot of 1 cm away from the discharge port of a developed fuel pump. The delivery pressure and delivery flow rate were measured at the spot of 30 cm away from the discharge port of the pump, and the pump efficiency was calculated. The pump motor speed was changed from 600 to 800, 1000, 1200 and 1400 rpm. It is found that the delivery feed rate of fuel pump is increased as the rotational speed is raised, and is decreased as the back pressure, compression pressure in the cylinder, is increased. Also, the pump efficiency is reduced as the rotational speed and back pressure are increased.

Flow characteristics of supersonic twin-fluid atomizers (초음속 2유체 분무노즐의 유동 특성)

  • Park, Byeong-Gyu;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2267-2276
    • /
    • 1996
  • Twin-fluid atomization has been widely used in combustors and process industries because of its high performance and simple structure. Flow visualization and pressure measurements were conducted to investigate the effects of gas flow in twin-fluid atomization. Schlieren photographs showed that changes in atomizing gas pressure, altered the wave patterns, and the lengths of both recitrculating toroid (impinging stangnation point) nad supersonic flow region in the jet. A longer supersonic wave pattern like net-shape wqas observed as atomizing gas pressure increased. The disintegration phenomenon of liquid delivery tube. The variation of spray angles with gas pressures were obtained by visualization using laser sheet beam. Suction pressuresat the nozzle orifice exit and recirculating region are shown to be used to estimate the stable atomization condition of a twin-fluid atomizer.

Self-Service Model Considering Learning Effect : Self-Service Gas Station (학습효과를 고려한 셀프서비스 모델 : 셀프서비스 주유소 분석)

  • Jung, Sung Wook;Yang, Hongsuk;Kim, Soo Wook
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.37 no.4
    • /
    • pp.73-93
    • /
    • 2012
  • In recent years, service delivery systems employing a self-service approach have been rapidly spreading. Since a self-service system provides a lower product price, it attracts more customers. However, some system managers are still hesitant to accept a self-service system, because there is no systematic model to predict its performance. Therefore, this research attempts to provide a systematic and quantitative model to predict the performance of a self-service system, focused specifically on a self-service gas station. Under this model, the traditional queuing theory was adopted to describe the general self-service process, but it is also assumed that some changes occur in both the customer arrival rate and the service performance rate. In particular, the price elasticity was introduced to capture the change in the customer arrival rate, and the existence of learning effect and helpers were assumed to design the changed service performance rate. Under these assumptions, a simulation model for a self-service gas station is established, and three performance measurements, such as average number of customers, average waiting time, and Utilization are observed, depending on the changes in price difference and helper-operating time. In this research, the optimal operation strategy for price differentiation and helper-operating time is proposed in accordance with the level of the customer learning rate. Although this research confines the scope of the study to the self-service gas station model, the results of this research can be applied to any type of self-service system.