• Title/Summary/Keyword: gas control

Search Result 3,580, Processing Time 0.123 seconds

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

Temperature Control of Oil Cooler with Hot-gas Bypass (토출가스 바이패스제어에 의한 산업용 냉각기의 온도제어)

  • Byun, Jong-Yeong;Joo, Woo-Jin;Choi, Jun-Hyuk;Moon, Choon-Geun;Yoon, Jung-In;Jeong, Seok-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.961-966
    • /
    • 2009
  • This paper presents precise temperature control of oil outlet in an oil cooler with hot-gas bypass control as an industrial refrigerator. The control system was designed for obtaining precise temperature control performance even though abrupt disturbances based on flow rate control of hot-gas bypass. PID controller was adopted in feedback control system. We showed that the gain of PID could be easily determined by using gain-tuning methods without any numerical model. Through some experiments, excellent control performances such as overshoot within 1.7%, steady state temperature error within ${\pm}0.1^{\circ}C$ were established by a simple PI controller. We expect that the system can control the target temperature within error of $0.33^{\circ}C$ under abrupt disturbances.

  • PDF

The Analysis and Control of Compressed Gas Discharging System (압축가스 방출 유압시스템 해석 및 제어)

  • 장웅락;김정관;한명철;정찬희;박인기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.458-462
    • /
    • 2004
  • The hydraulic system for discharging compressed gas is composed of compressor tank, proportional flow control servo valve, expulsion spool valve and discharging tube. Purpose of this study is to control of expulsion spool valve. First, we analyzed the hydraulic system. The flow control servo valve is modeled as a 2nd order transfer function and friction force of the expulsion spool valve is modeled as nonlinear model with stribeck effect. However, it is difficult to include the flow reaction force in modeling. So, we exchanged from the simplified flow reaction force of the compressed gas affection into the flow analysis code written in FORTRAN code. Our simulation of the oil pressure system for discharging gas used MATLAB/Simulink. So, we realized 'Level -2 S-Function Fortran' to cooperate for MATLAB/Simulink and FORTRAN code. PD controller is selected to control in this system. Simulation results show that with given conditions the controllers give a good tracking performance.

  • PDF

Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler (산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.429-435
    • /
    • 2011
  • In this study the operational characteristics of the temperature control system between an on-offemployed cooler and a bypass type cooler is analyzed. Currently an on-off controller employed coolerwhich is the industry's leading type on the market for industrial coolers is used. The new type cooler isused a bypass controller at discharge gas. The COP of the bypass controlled cooler with discharge gas is at least 8% higher than the on-off controlled cooler. The maximum COP difference is about 20%. Based on the results, the bypass control with discharge gas shows the possible temperature control with high precision.

A combustion control modeling of coke oven by Swarm-based fuzzy system (스왐기반 퍼지시스템을 이용한 코크오븐 연소제어 모델링)

  • Ko, Ean-Tae;Hwang, Seok-Kyun;Lee, Jin-S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.493-495
    • /
    • 2005
  • This paper proposes a swarm-based fuzzy system modeling technique for coke oven combustion control diagnosis. The coke plant produces coke for the blast furnace plant in steel making process by charging coal into oven and supplying gas to carbonize it. A conventional mathematical model for coke oven combustion control has been used to control the amount of gas input, but it does not work well because of highly nonlinear feature of coke plant. To solve this problem, swarm-based fuzzy system modeling technique is suggested to construct a diagnosis model of coke oven combustion control. Based on the measured input-output data pairs, the fuzzy rules are generated and the parameters are tuned by the PSO(Particle Swarm Optimizer) to increase the accuracy of the fuzzy system is operated. This system computes the proper amount of gas input taking the operation conditions of coke oven into account, and compares the computed result with the supplied gas input.

  • PDF

A Design of Realtime Monitoring System of Automatic gas Control DC-MOTOR for Single Crystal($A1_2O_3$) growth (단결정($A1_2O_3$) 성장을 위한 자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 구현)

  • Lee, Hyung-Chung;Park, Chong-Kug;Cho, Hyeon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2489-2491
    • /
    • 2004
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal($A1_2O_3$) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($A1_2O_3$) growth and we will design about realtime monitoring systems of the automatic gas control DC- Motor for single crystal($A1_2O_3$) growth.

  • PDF

Speed Control of Marine Gas Turbine Engines Using a RCGA and Fuzzy Technique (RCGA와 퍼지기법을 이용한 선박용 가스터빈 엔진의 속도제어)

  • So, Myung-Ok;Lee, Yun-Hyung;Jin, Gang-Gyoo;Jung, Byung-Gun;Kang, In-Chul
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.274-280
    • /
    • 2005
  • The system parameters of gas turbine engine tend to change remarkably in real operating condition. It means that operators have to consider environment and suitably control fuel flow. The conventional PID controller, however, can not guarantee good control performance in the aspect of system parameter change. This paper, therefore, proposes a scheme for integrating PID control and fuzzy technique to obtain the good performance of gas turbine engine speed control on the whole operating range. The effectiveness of the proposed fuzzy PID controller is verified through computer simulation.

  • PDF

Effect of Anaerobic Treatments on the ${\gamma}-Aminobutyric$ acid and Quality of Green Tea(Camellia sinensis var. sinensis) (차잎 혐기처리가 녹차의 기능성분 및 품질에 미치는 영향)

  • Park, Jang-Hyun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.1
    • /
    • pp.26-32
    • /
    • 2001
  • The contents of chemical components such as total nitrogen, total amino acid and vitamin C were somewhat higher in $N_2$ gas treatment at $10^{\circ}C$ for 3 hours than those of other treatments. However, the contents of tannin and chlorophyll were slightly lower than that in the other treatments. The content of ${\gamma}-Aminobutyric$ acid with $N_2$ gas treatment was higher $1.5{\sim}6$ times with values of $51{\sim}205mg/100g$ than in control (35mg/100g). The scores of sensory test was not different between $N_2$ gas treatment for 3 hours and control. The contents of chemical components such as total nitrogen, total amino acid including theanine and caffeine were slightly higher in $N_2$ gas treatment at $20^{\circ}C$ for 3 hours than those of other treatments. However, the contents of tannin and vitamin C were slightly lower than those of other treatment. The content of GABA in tea leaves treated with $N_2$ gas was higher $2.5{\sim}7$ times with values of $85{\sim}225mg/100g$ than in control (35mg/100g). The sensory test was lower in $N_2$ gas treatment($76.3{\sim}78.1$ point) than in control(80.4 point). The contents of chemical components were not different between $N_2$ gas treatment at $30^{\circ}C$ for 3 hours and control. Whereas the contents of chemical components were somewhat lower in $N_2$ gas treatment for 1 hour and 5 hours than in control. The content of GABA in tea leaves treated with $N_2$ gas was higher $3{\sim}7$ times with values of $115{\sim}217mg/100g $than in control(35mg/100g). The sensory test was lower in $N_2$ gas treatment ($74.3{\sim}78.4$ point) than in control(80.4 point). Consequently, tea mading within 5 time $N_2$ gas treatment at $10^{\circ}C$ or 3 time $N_2$ gas treatment at 20, $30^{\circ}C$ after plucking was considered to be the best green tea in terms of functional nature as well as taste nature.

  • PDF

Quality Changes of Strawberry by Slow-released ClO2 Gas Gel-pack during Storage (서방형 이산화염소 가스 젤팩을 이용한 딸기의 저장 중 품질 변화)

  • Lee, Kyung-Haeng;Bong, So-Jung;Yoon, Ye-Ji;Lee, Bom;Kwak, Il-Hwan;Min, Kyung-Hoon;Kim, Hong-Gil
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.3
    • /
    • pp.591-598
    • /
    • 2017
  • To prolong the shelf-life of strawberry, samples were treated with gel packs containing slow-released chlorine dioxide($ClO_2$) gas at 3~7 ppm for 6 days at room temperature. The weight loss and decay ratio as well as changes in pH, color and texture properties of the treated samples were investigated. The weight of the control and $ClO_2$ gas treated samples decreased slightly, but the weight of the control changed faster than those of the $ClO_2$ gas treated samples during the storage period. The decay ratio of control was higher than those of the $ClO_2$ gas treatments since 4 days of storage. The pH and acidity in the control and in the $ClO_2$ gas treated samples were no differences during storage period. The lightness of strawberry decreased during storage, but there was no difference in lightness among the treatments even when storage time was extended. The redness and yellowness of the control showed higher change than those of the $ClO_2$ gas treatments during 6 days. The firmness of the control changed more rapidly than those of the $ClO_2$ gas treatments during 6 days. Especially, the samples treated 3 and 5 ppm $ClO_2$ gas were the least changed. And the scores for appearance, firmness and overall acceptance control and 7 ppm $ClO_2$ gas treatment decreased more rapidly than those of 3 and 5 ppm treatment.

Development of the Gas Charging Simulator for Reaction Control System of KSLV-I (KSLV-I RCS 충전모사 시스템 개발)

  • Jeon, Sang-Woon;Jung, Seul;Kim, Ji-Hun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.122-126
    • /
    • 2009
  • KSLV(Korea Space Launch Vehicle)-I is designed as a launch vehicle to enter a 100 kg-class satellite to the LEO(Low-Earth Orbit). Attitude angles of the upper-stage, including roll, pitch and yaw are controlled by cold gas thruster system using nitrogen gas. To verify the flow rate of the gas charging system and to prepare a nitrogen gas charging scenario, the development of a gas charging simulator for RCS(Reaction Control System) is required. This paper describes the orifice design, development, and test of the gas charging simulator for RCS of KSLV-I.

  • PDF