• Title/Summary/Keyword: gas control

Search Result 3,580, Processing Time 0.03 seconds

Application a Loop Compensation type 2-DOF PID Controller tuned by Neural Network to Gas Turbine Control Loop (가스터빈 제어 루프에 대한 신경망 튜닝 루프 보상형 2-자유도 PID 제어기의 응용)

  • Kim, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.781-786
    • /
    • 1998
  • Since a gas turbine is still a significant contributor to peak time, it is very important to tune the gains of P. I. D to get a maximum power and stability within permissible limits. In the gas turbine, the main control loop must adjust the fuel flow to ensure the correct output power and frequency. but it is not easy, because the control loop is composed of many subsystems. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply a loop compensation type 2-DOF PID controller tuning by neural-network to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas

  • Suh, Jeong-Se;Park, Young-Sik;Chung, Kyung-Taek;Kim, Byoung-Gi
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.4
    • /
    • pp.125-130
    • /
    • 2006
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with screen meshed wick. The active length of condenser section in a VCHP is varied by non-condensible gas, which controls the operating temperature, and the heat capacity of VCHP is controlled by the operating temperature. In this study, numerical analysis of the VCHP based on the diffusion model of non-condensible gas is done for the thermal control performance of VCHP. Water is used as a working fluid and nitrogen as a control non-condensible gas in the copper tube. As a result, the thermal conductance of VCHP has been compared with that of constant conductance heat pipe (CCHP) corresponding to the variation of operating temperature.

Development of a GVT (Gas Valve Train) Control System for LNG Fueled Vessels (LNG 추진 선박 엔진용 GVT 제어 시스템 개발)

  • Kang, Inpil;Kim, Kyu-Cheol
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.70-76
    • /
    • 2017
  • This paper presents the development of a Gas Valve Train (GVT) control system which is the core equipment of LNG fueled vessels. Due to the increasing worldwide demand for echo friendly green ship products, domestic companies urgently require to develop a core equipments for the LNG fueled vessels to secure worldwide markets in marine engineering. A LNG fueled engine generally equips the GVT, a fuel supply system that steadily supplies clean high-pressure LNG to the engine. The GVT requires a safety operational control system that can prevent any gas leakage accident, and a system that monitors operation status in real time. Therefore, we introduces a development for GVT control and monitoring system design and the design was systematically performed by means of functional analysis and differentiation of foreign advanced products.

Analysis of Thermal Control Performance of Variable Conductance Heat Pipe with Axial Grooves (축방향 그루브형 가변전열 히트파이프의 열제어 특성)

  • Park, Y.S.;Kim, D.E.;Byon, G.S.;Suh, J.S.;Lee, K.W.;Park, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1651-1656
    • /
    • 2003
  • The present study has been conducted to analytically investigate the thermal control performance of variable conductance heat pipe(YCHP) with axial grooves. The condenser port of the YCHP is occupied by a inert gas in which the concentration of gas is varied with the operation temperature and the heat transport capacity is thus varied with the operating temperature due to the variation of inert gas concentration. In this study, numerical evaluation for the thermal control of the YCHP with axial grooves is made from the 1st order diffusion model that considers the diffusive expansion of inert gas by concentration gradient. Ammonia is used as a working fluid and Nitrogen as a control gas in the Aluminum tube. As a result, the thermal performance of YCHP based on diffusion model has been compared with that of YCHP from flat front model. Additionally, it is found that the concentration of inert gas is distributed in the condenser region of YCHP with axial grooves.

  • PDF

Analysis of the Control Variables for Natural Gas Liquefied Process Using Mixed Refrigerant (혼합냉매를 이용한 천연가스 액화공정의 제어변수 분석)

  • Lee, Jae Yong;Kim, Mun-Hyun;Park, Chan-Cook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.51-57
    • /
    • 2013
  • The process of liquefied natural gas is less then $-160^{\circ}C$ to natural gas by cooling at atmospheric pressure. When control strategy was made, one of the most significant is analysis of process. It is important to understand the control variable change according to manipulated variable change. In this study, we experiment natural gas liquefied process using C3MR(Propane Pre-cooled Mixed Refrigerant) process by BSU(Bench Scale Unit). We analyzed the change of refrigerant temperature and natural gas temperature according to the change of refrigerant flow rate so as to search an influence flow rate according to adjust each manipulated variables. One of the manipulated variable affected a number of control variables, but were able to confirm a control variable with a large response.

Field Inspection of Phase-Array Ultrasonic for PolyEthylene Electrofusion Joints

  • Kil, Seong-Hee;Jo, Young-Do;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.22-25
    • /
    • 2012
  • Welding and/or fusion in polyethylene(PE) system made on site is focused on the control of the welding or fusion process to follow proper procedure. The process control is important, but it is not sufficient for the long term reliability of a pipe system. To achieve the rate of failure close to zero, Non Destructive Testing(NDT) is necessary in addition to joining process control. For electrofusion joints several non-destructive testing methods are available. The ultrasonic phased array technique is possible to detect various defects including wire deviations and regions with lack of fusion. In this studies, testing was carried to detect the defect after electrofusion joining of polyethylene piping is utilized by the ultrasonic phased array technique. From testing data, ultrasonic phased array technique is recommended as a reliable non-destructive testing method.

Gas turbine Control using Neural-Network 2-DOF PID Controller

  • Kim, Dong-Hwa
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.03a
    • /
    • pp.61-66
    • /
    • 1998
  • Since a gas turbine is made use of generating electricity for peak time, it is a very important to operate a peak time load with safety. The main components of a gas turbine are the compressor, the combustion chamber and the turbine. So, there also must be modeled a component of gas turbines for the control with safety but it is not easy. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply Neural-Network 2-DOF PID controler to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

Characteristic of Hydrogen-oxygen Mixed Gas Power Conversion System (혼합수소발생기용 전력변환장치의 특성)

  • Mun, Sang-Pil;Lee, Hae-Su;Nakaoka, Mutsuo;Jeong, Jang-Geun;Kim, Chang-Il;Jo, Gil-Je;Kim, Sang-Don
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.323-326
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using SCR converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input rower, it has acquired higher input power per Gas quantities at put pulse current. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

Development of Standard Checklist for Safety Management of Toxic Gas facility in Domestic University Laboratory (국내 대학 실험실 독성가스 시설의 안전관리를 위한 표준 체크리스트 개발)

  • Lee, Sungjin;Kim, Byung-Duk;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.92-98
    • /
    • 2015
  • Toxic gases are managed by High Pressure Gas Safety Control Act. Toxic Gases are "31 designated species and each gas of which the permissible concentration($LC_{50}$) is equal to or less than 5000 ppm as defined in High Pressure Gas Safety Control Act.". Korean toxic gas usage in accordance with the growth of the electronic industry has increased explosively. The demand of toxic gas research in domestic university laboratories has grown together. But the research associated with toxic gas safety management in the domestic laboratory is nonexistent state. In this study, we identified weak points of toxic gas safety management through a survey of domestic university laboratory facilities. This paper presented toxic gas safety measures in order to overcome those weak points. Also this paper developed a standard checklist to improve and ensure safe management of toxic gas facility in accordance with the proposed measures. This research is to enforce safety management of toxic gas facilities in domestic university laboratory and it will provide safety guidelines for every laboratory.