• 제목/요약/키워드: gas chromatography-mass selective detector

검색결과 57건 처리시간 0.029초

Gas-Chromatography/Mass Selective Detector를 사용하여 쥐의 뇨시료 중 benzidine 대사체의 확인 및 in vitro 독성 (Identification of Benzidine Metabolites in Rats by Gas Chromatography/Mass Selective Detector and its Toxicity in vitro)

  • 류재천;권오승
    • 약학회지
    • /
    • 제44권5호
    • /
    • pp.384-390
    • /
    • 2000
  • Metabolism study of the dye, benzidine, was performed by gas chromatography-mass selective detector (GC/MSD) in the urine of rats orally administered 100 mg/kg benzidine. Urine samples were collected in metabolic cages for 0-24, 24-48, and 48-72 hrs. Ten ml of the urine was extracted with XAD-2 resin and the XAD-2 column was eluted with methanol. After evaporation, benzidine and its metabolites were extracted with diethyl ether (for non-conjugated fraction). For conjugated metabolites, $\beta$-glucu-ronidase was added to the aqueous layer that was incubated for 1 hr at 5$0^{\circ}C$ and the aqueous layer was extracted as in non-conjugated fraction. Aliquot of trimethylsilylated derivatives was applied to the GC/MSD. The mutagenicity of benzidine and its acetylated metabolites was tested by histidine/reversion assay. Five metabolites observed and confirmed either by electron impact and chemical ionization modes of the GC/MSD, or authentic compounds were monoacetyl-, diacetyl-, hydroxyacetyl-, hydroxydiacetyl-, and hydroxy-benzidine. Monoacetyl-benzidine was more potent than benzidine in histidine/reversion assay. This data indicates that monoacetylation of benzidine may be one of the metabolites produced in metabolic activation process.

  • PDF

요중 알파나프틸아민 분석에 관한 연구 (The study on the analysis of α-naphthylamine in urine)

  • 김춘성;노재훈;배문주;김치년;임남구;원종욱
    • 한국산업보건학회지
    • /
    • 제7권1호
    • /
    • pp.49-59
    • /
    • 1997
  • This study was performed to analyze the purity of technical grade ${\alpha}$-naphthylamine, to establish optimal analytical condition of ${\alpha}$-naphthylamine in urine and to determine the urine sample of workers exposed to ${\alpha}$-naphthylamine. The purity of technical grade ${\alpha}$-naphthylamine were $96.5{\pm}2.38%$, $94.1{\pm}0.97%$, $97.0{\pm}0.02%$ by gas chromatography-mass selective detector. To analyze ${\alpha}$-naphthylamine in urine, high performance liquid chromatography-electrochemical detector and gas chromatography-electron capture detector operating conditions have been optimized by preliminary expriment. In high performance liquid chromatography-electrochemical detector, the mobile phase was consisted of acetonitrile(35%) and water(65%), and the flow rate was maintained at 1.0ml per minute. Optimal detective condition was 9.0V(10nA/V) of electrochemical detector. The recovery of sep-pak treatment method was highly estimated as pretreatment of ${\alpha}$-naphthylamine in urine. The free amine was isolated by gas chromatography-electron capture detector after basic hydrosis, sep-pak treatment, toluene elution and HFBA(heptafluoro-butyric anhydride) derivatization of urine. The recovery of ${\alpha}$-naphthylamine in urine was $98.73{\pm}3.29%$ by gas chromatography-electron capture detector. The sensitivity was more higher than that of high performance liquid chromatography-electrochemical detector. Urinary ${\alpha}$-naphthylamine was detected in only one worker among nine workers. The level of ${\alpha}$-naphthylamine in urine was 6.42 ng/ml.

  • PDF

기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구 (Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권3호
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

Gas Chromatography-Electron Capture Detector를 이용한 산분해간장중의 3-Monochloro-1, 2-propanediol 분석법에 관한 연구 (Determination of 3-Monochloro-1, 2-propanediol in Acid Hydrolyzed Soysauce(Ganjang) by Gas-Chromatography with Electron Capture Detector)

  • 최종동;문귀임;오현숙;김동술
    • 한국식품위생안전성학회지
    • /
    • 제16권1호
    • /
    • pp.61-65
    • /
    • 2001
  • Electron capture deteotor가 장착된 gas chromatography를 이용하여 간장에서 3-monochloro-1, 2-propanediol(MCPD)의 효율적인 분석조건을 조사하였다. MCPD를 직접 분석하는 것 보다 MCPD를 phenylboric acid로 유도체화하여 분석하는 경우가 sharp한 peak를 얻을 수 있었으며, 감도도 우수하였다. 유도체화 방법을 실온에서 5분간 vortex혹은 9$0^{\circ}C$에서 20분 반응시켜 분석한 결과, R값이 각각 0.9997과 0.9977로 큰 차이를 보이지는 않았다. MCPD의 추출방법은 Extrelut 3 column을 사용하는 것이 ethyl acetate로 직접 추출하는 것보다 회수율이 월등히 높았으며, MCPD의 농노가 높을수록 회수율이 낮게 나타났다. 하지만 MCPD를 정성적으로 분석하고자 할 경우 ethyl acetate로 직접 추출하는 방법도 유효한 것으로 나타났다. 간장에 MCPD를 spiking 하고 gas chromatography-electron capture detector 및 gas chromatography-mass selective detector로 분석한 결과 sharp한 모양의 peak를 얻을 수 있었으며, mass spectrum으로 MCPD를 확인할 수 있었다.

  • PDF

Identification of Homoserine Lactone Derivatives Using the Methionine Functionalized Solid Phase Synthesis by Gas Chromatography/Mass Spectrometry

  • Moon, Hong-Sik
    • Archives of Pharmacal Research
    • /
    • 제27권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Combinatorial homoserine lactone mixtures and individual products were obtained from the methionine-functionalized resin in solid-phase synthesis. The four-step process consisting of a coupling step of an N-Fmoc-L-methionine, deprotection of N-Fmoc group, N-coupling with a carboxylic acid, and cleavage reaction through a polymer supported strategy is described. Gas chromatography-mass selective detector (GC-MSD) techniques provide the most powerful methods for identifying both the combinatorial mixtures and individual products.

Bioavailability Test of TestoTM Tablets (Methyltestosterone, 25 mg) in Male Healthy Volunteers by a Gas-chromatography/Mass Selective Detector

  • Kwon, Oh-Seung;Kim, Hye-Jung;Pyo, Hee-Soo;Kim, Dae-Duk;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권5호
    • /
    • pp.383-388
    • /
    • 2005
  • A simple and specific method for determination of methyltestosterone (MT) has been established by a gas chromatography/mass selective detector and applied in plasma of healthy male volunteers received a single oral dose of 50 mg MT $(Testo^{TM}\;tablets,\;25\;mg)$ for bioavailability test. This method involves using liquid-liquid extraction of the sample with diethyl ether and derivatization with MSTFA. MT showed good resolution in this condition. The detection limit of quantitation was 5 ng/ml. A good linearity (r>0.996) was obtained at the range of 5-250 ng/ml of MT. Intra-day precision and accuracy were 2.76-12.56% and 0.39-8.01 %, and inter-day precision and accuracy were 2.29-17.69% and 0.42-7.99%, respectively. The established method was applied on bioavailability test of MT in human volunteers. The value of $AUC_{0\;to\;last}$ to last was $264.5{\pm}123.9\;ng{\cdot}hr/ml$ and that of $AUC_{0\;to\;inf}$ was determined to be $275.2{\pm}126.5\;ng{\cdot}hr/ml$. The values of $C_{max}$ and $T_{max}$ were $95.9{\pm}67.1\;ng/ml$ and $1.13{\pm}0.9\;hr$, respectively. The mean elimination half-life $(t_{1/2})$ was $4.4{\pm}0.9\;hr$. This analytical method is suitable and useful for the pharmacokinetics and bioequivalence studies of MT.

Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석 (Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector)

  • 홍인석;최윤화;권택부;이정학
    • 한국동물위생학회지
    • /
    • 제28권3호
    • /
    • pp.285-294
    • /
    • 2005
  • This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석 (Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD))

  • 홍인석;최윤화;권택부;이정학
    • 한국동물위생학회지
    • /
    • 제29권3호
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

Polychlorinated biphenyl 전처리한 횐쥐 간장의 S-9 분획에서 Stanozolol의 Hydroxylation 대사체의 생성 (In vitro Metabolism of Stanozolol to 3'-Hydroxystanozolol in the Liver S-9 Fraction of Polychlorinated Biphenyl-treated Rats)

  • 권오승;류재천
    • 약학회지
    • /
    • 제44권5호
    • /
    • pp.379-383
    • /
    • 2000
  • Stanozolol (STZ, 17$\alpha$-methyl-17$\beta$-hydroxy-5$\alpha$-androstano-(3,2-c) pyrazole), an anabolic steroid, is an abused drug by body-builders or atheletes, as well as medicine for treatment of aplastic anemia and vascular thrombosis. In human volunteers, the major urinary metabolite of STZ was reported to be 3'-hydroxystanozolol that was identified by gas chromatography-mass selective detector (GC/MSD). The objective of this experiment is to investigate the in vitro metabolism of STZ in liver S-9 faction of polychlorinated biphenyl-induced rats. Reaction mixture including STZ as substrate and the S-9 faction was extracted with diethyl ether and quantified by the selected ion monitoring mode of GC/MSD. The selected concentration of substrate STZ is 100 nmole and the selected time for incubation in the reaction mixture was determined to 60 min. The amount of 3'-hydroxystanozolol produced was increased by about 6-fold in the reaction medium including the liver S-9 fraction of polychlorinated biphenyl-induced rats, compared to that of untreated rats. Inhibitors of cytochrome P450, SKF-525A and 7,8-benzoflavone, decreased the production of 3'-hydroxystanozolol by about 89~100% and 65~75%, respectively; In conclusion, hydroxylation of STZ into 3'-hydroxystanozolol is confirmed by GC/MSD and is catalyzed by cytochrome P450.

  • PDF