• Title/Summary/Keyword: gas boiler

Search Result 365, Processing Time 0.027 seconds

Virtual Analysis of District Heating System Using ENetPLAN (EnetPLAN을 이용한 지역난방시스템 가상 운전 분석)

  • Ahn, Jeongjin;Lee, Minkyung;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.18-25
    • /
    • 2019
  • In this study, in order to solve the problem of the program of calculating code input by experienced users in the power generation, the wide area energy network research group developed the local heating operation analysis program EntPLAN, which can be easily used by anyone, including scalability, with domestic technology. Therefore, the Commission intended to compare the heat sources, heat demand, and the results of operation of the combined heat plant (CHP) on the energy network through simulation with the EnetPLAN and the program A on the market. The results showed that the heat and power output on the energy network of the EnetPLAN and A programs were mostly similar in pattern in the simulation results of the heat supply and the operation method of the accumulator. This enabled the application of the simulation for the various operation modes of the cogeneration facilities existing on the energy network. It is expected that EntPLAN, which was developed with domestic technology, will be easily applied in the field in the future and will present efficient operation simulation results.

International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES) (친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구)

  • Shim, Byoung Ohan
    • Economic and Environmental Geology
    • /
    • v.51 no.1
    • /
    • pp.67-76
    • /
    • 2018
  • This study reviews three eco-friendly energy towns with hybrid thermal energy supply systems and borehole thermal energy storage (BTES) in Canada and Denmark. The district heating and cooling systems were designed by using multi-source energy for the higher efficiency and reliability as well as environment. ADEU (Alexandra District Energy Utility) located at the developing area in the city of Richmond, Canada was designed to supply district energy with the installation of 726 borehole heat exchangers (BHEs) and a backup boiler using natural gas. DLSC (Drake Landing Solar Community) located in the town of Okotoks, Canada is a district system to store solar thermal energy underground during the summer season by seasonal BTES with 144 BHEs. Brædstrup Solpark district heating system located in Denmark has been conducted energy supply from multiple energy sources of solar thermal, heat pump, boiler plants and seasonal BTES with 48 BHEs. These systems are designed based on social and economic benefits as well as nature-friendly living space according to the city based energy perspective. Each system has the energy center which distribute the stored thermal energy to each house for heating during the winter season. The BHE depth and ground thermal storage volume are designed by the heating and cooling load as well as the condition of ground water flow and thermophysical properties of the ground. These systems have been proved the reliance and economic benefits by providing consistent energy supply with competitive energy price for many years. In addition, the several expansions of the service area in ADEU and Brædstrup Solpark have been processed based on energy supply master plan. In order to implement this kind of project in our country, the regulation and policy support of government or related federal organization are required. As well as the government have to make a energy management agency associated with long-term supply energy plan.

A Study on the Development of Marine Fuel Oil Homogenizer for Fuel Costs Saving (연료비 절감을 위한 선박용 연료유 균질기 개발에 관한 연구)

  • Han, Sang-Goo;Choi, Jung-Sik;Park, Ro-Seong;Kim, Dae-Hun;Ryu, Kyoung-Boo;Chun, Kang-Woo;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.584-590
    • /
    • 2012
  • In this study, we have conducted a work on homogenizer development which is operated by high shearing force generated by stator and rotor inside it. To investigate the performance for homogenization and atomization of homogenizer, Bunker-C (IFO 380 cSt) was used as a fuel for experiment. Pre-treatment of bunker-C was carried out with homogenizer developed in this study. Oil purifier was used to investigate effect of oil sludge reduction after pre-treatment. Experimental result showed that the amount of sludge of fuel oil after pre-treatment with homogenizer has decreased by 13 %. To confirm combustion efficiency, Bunker-C which have pre-treatment with homogenizer and purified after are burned in boiler system. The result showed that CO concentration in exhaust gas was decreased. These results mean that if the homogenizer which is developed in this study for marine fuel oil is applied on real vessels, oil costs and operating costs can be reduced.

The Source Identification of Spilled Oil by Pristane/Phytane Ratio

  • Bae, Il-Sang;Kweon Jung;Oh, Hyun-Jung;Shin, Ho-Sang;Lee, Jae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.4
    • /
    • pp.64-67
    • /
    • 2003
  • In order to identify the origin and nature of the spilled oil in the potential source, we analyzed the concentrations of specific fuel constituents in fuel standard and environmental samples. The ratios of pristane/phytane are virtually unaltered because these compounds have the same bolatility in environmental samples. These were useful to identify the source of the fuel oil and to assess the effect of microbial degradation and weathering of the fuel oil. We analyzed the ratios of pristane/phytane in neat white kerosene, boiler kerosene, JP-8 and diesel products from L and S gas station. The ratios of pristane/phytane in L-white kerosene and JP-8 was 3.10 $\pm$0.03 and 1.77 $\pm$ 0.01, respectively. Otherwise, the ratios of pristane/phytane in water phase after distribution of fuel oil and water was 2.97 $\pm$0.02 in case of white kerosene and 1.65 $\pm$ 0.02 in case of JP-8. It is apparent from the results that the ratios of pristane/phytane were as product-specific, especially between kerosene and JP-8, and therefore, can also be used for fuel type identification in free products and groundwater samples which were collected in monitoring wells.

A Study on the PCDDs/PCDFs Contents in the Flue Gas of Muncipal Solid Waste Incinerator(III) -Emission Concentration Varying the Combustion Temperature- (쓰레기소각로 배출가스의 PCDDs/PCDFs 함유량에 관한 연구(III) -소각로 연소 온도변화에 따른 보일러 후단에서의 배출 농도 변화-)

  • Shin, S.K.;Chung, Y.H.;Lee, J.I.
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.540-549
    • /
    • 1999
  • The combustion temperature was controlled between $880^{\circ}C$ to $1070^{\circ}C$ to find the relation the combustion temperature and emission amount of PCDDs/PCDFs in the Municipal solid waste incinerator. The emission amount of PCDDs/PCDFs decreased when the temperature increased in the rear of the boiler. The PCDDs/PCDFs concentration were detected $7.82ng-TEQ/Nm^3$ at $880^{\circ}C$, $6.97ng-TEQ/Nm^3$ at $970^{\circ}C$ and $6.13ng-TEQ/Nm^3$ at $1070^{\circ}C$. Also, The chlorophenols, chlorobenzenes, and PCB concentration decreased by increasing the temperature from $880^{\circ}C$ to at $1070^{\circ}C$, and the isomer of the prescsors had a tendency to emit the higbly cbiorinated compounds.

  • PDF

Physical, Morphological, and Chemical Analysis of Fly Ash Generated from the Coal Fired Power Plant (석탄 화력발전소에서 발생되는 석탄회 특성과 형성 분석에 관한 연구)

  • 이정언;이재근
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.146-156
    • /
    • 1998
  • Fly ash produced in coal combustion is a fine-grained material consisting mostly of spherical, glassy, and porous particles. A physical, morphological, and chemical characteristic of fly ash has been analyzed. This study may contribute to the data base of domestic fly ash, the improvement of combustion efficiency, ash recycling and ash collection in the electrostatic precipitator. The physical property of fly ash is determined using a particle counter for the measurement of ash size distribution and gravimeter. Morphological characteristic of fly ash is performed using a scanning electron micrograph and an optical microscope. The chemical components of fly ash are determined using an inductively coupled plasma emission spectrometry (ICP). The distribution of fly ash size was ranged from 15 to 25 $\mu$m in mass median diameter. Exposure conditions of flue gas temperature and duration within the combustion zone of the boiler played an important role on the morphological properties of the fly ash such as shape, relative opacity, coloration, cenosphere and plerosphere. The spherical fly ash might be generated at the condition of complete combustion. The size of fly ash was found to be increased the with particle-particle interaction of agglomeration and coagulation. Fly ash consisted of $SiO_2\;Al_2O_3\;and\;Fe_2O_3$ with 85% and carbon with 3~10% of total mass.

  • PDF

Unresolving Pneumonia (치료에 대한 반응이 없는 폐렴)

  • Bang, Do Seok;Jung, In Sung;Kang, Ki Man;Park, Bum Chul;Yoon, Young Gul;Kim, Jae Su;Park, Yol;Lee, Sung Hoon;Hong, Young Chul;Ko, Kyoung Tae;Park, Sang Min;Na, Dong Jib
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.604-608
    • /
    • 2004
  • A 47-year-old-man was admitted to the emergency department with dyspnea, right pleuritic pain, and high fevers for 3 days. He had a nonproductive cough that exacerbated the chest pain. A clinical examination revealed distressed and slightly tachypneic patient, with blood pressure of 110/90 mmHg, temperature of $39^{\circ}C$, pulse of 90 beats/min, respiratory rate of 24 breaths/min. A chest examination showed significantly diminished breath sounds in the right lung with dullness to percussion. Laboratory investigation demonstrated leukocytosis and a raised C-reactive protein. The results of arterial blood gas analysis revealed moderate hypoxemia. A radiograph and a CT scan of the chest showed extensive consolidation with multifocal low densities, and pleural effusion in the right lung. A diagnostic thoracentesis revealed straw-colored fluid, which was found to be a neutrophil-predominant exudate. At 7 days after admission, the clinical symptoms had not improved and the temperature was still $39^{\circ}C$ despite the aggressive therapy of community-acquired pneumonia. After comprehensive history taking, we realized then that he accidentally aspirated kerosene while siphoning from fuel tank to put into the boiler 3 days ago. Bronchoscopy with bronchial washings could be successful in establishing the diagnosis of hydrocarbon pneumonitis by demonstration of a high lipid-laden macrophage index. Thereafter, the symptoms and radiographic opacities gradually improved, and he was discharged several days later.

Welding Fume and Metals Exposure Assessment among Construction Welders (건설현장 용접직종별 용접흄 및 금속류 노출 실태)

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.147-158
    • /
    • 2016
  • Objectives: The objective of this study was to evaluate the assessment of exposure to welding fume and heavy metals among construction welders. Methods: Activity-specific personal air samplings(n=206) were carried out at construction sites of three apartment, two office buildings, and two plant buildings using PVC(poly vinyl chloride) filters with personal air samplers. The concentration of fumes and heavy metals were evaluated for five different types of construction welding jobs: general building pipefitter, chemical plant pipefitter, boiler maker, ironworker, metal finishing welder. Results: The concentration of welding fumes was highest among general building pipefitters($4.753mg/m^3$) followed by ironworkers($3.765mg/m^3$), boilermakers($1.384mg/m^3$), metal finishing welders($0.783mg/m^3$), chemical pipefitters($0.710mg/m^3$). Among the different types of welding methods, the concentration of welding fumes was highest with the $CO_2$ welding method($2.08mg/m^3$) followed by SMAW(shield metal arc welding, $1.54mg/m^3$) and TIG(tungsten inert gas, $0.70mg/m^3$). Among the different types of workplace, the concentration of welding fumes was highest in underground workplaces($1.97mg/m^3$) followed by outdoor($0.93mg/m^3$) and indoor(wall opening as $0.87mg/m^3$). Specifically comparing the workplaces of general building welders, the concentration of welding fumes was highest in underground workplaces($7.75mg/m^3$) followed by indoor(wall opening as $2.15mg/m^3$). Conclusions: It was found that construction welders experience a risk of expose to welding hazards at a level exceeding the exposure limits. In particular, for high-risk welding jobs such as general building pipefitters and ironworkers, underground welding work and $CO_2$ welding operations require special occupational health management regarding the use of air supply and exhaust equipment and special safety and health education and fume mask are necessary. In addition, there is a need to establish construction work monitoring systems, health planning and management practices.

Living Conditions of the Rural Elderly: Clothing, Nutrition, Housing, and Psychological Adjustment (농촌지역 노인의 생활실태 조사연구 -의.식.주생활 및 심리적 적응을 중심으로-)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.4
    • /
    • pp.65-86
    • /
    • 1990
  • Living conditions of the rural elderly were assessed in terms of clothing behavior, health and nutritional status, housing and envioronmental condition, and psychological adjustment. The subjects were eighty individuals over sixty residing in the rural community of Iksan-kun, Chollabukdo. The interview method using questionnaires, direct measurement, and observation was used for this study. Data were compared with those obtained from a previous study of the elderly residing in an urban area. Clothing behavior showed that the elderly residing in the rural community were more concerned about plain and conservative design of clothes than their urban counterparts. Special protective clothes for cropdusting with agricultural chemicals had not been prepared. The following urgent needs were pointed out: development and supply of agricultural chemical protective clothing and development and education of appropriate washing and clothing care methods. The health status of the elderly was generally good, but poor eating habits were found more frequently in the rural elderly than among the urban dwellers. Several dietary nutrient intakes were insufficient. Contrasting the urban elderly with the rural group, it was found that the urban group lacked sufficient vitamin A and vitamin C and the urban women had insufficient calorie whereas the rural group was deficient in protein, vitamin A, calorie, and fat. A significant relationship was found between dietary nutrient intake and health index, food habit points, self recognized health status, meal satisfaction, and economic status. Urgent needs of the development of a nutrition education program for the elderly were pointed out. Most of elderly residing in the surveyed rural communities were living alone or with their spouse only, therefore only one room was used among the three or four available rooms. Most of the rural elderly were living either in a traditional Korean house built with differing floor levels or in a modified Korean style house. Minimal modernization had been made for kitchen facilities such as sink and gas range or for heating facilities with the briquette boiler. However, sanitary space such as lavatory and bathroom had not been remodeled. A housing welfare program for rural communities should be implemented at the national level. The comparison of psychological characteristics of the rural elderly with their city counterparts revealed that the rural elderly have a more stable psychological status and optimistic attitude than those living in a city. However, it was found that most of the elderly did not have any future plan. Community programs for the elderly including hobbies or leisure activities or education programs to generate close interpersonal relationships with their children should be developed and provided.

  • PDF

Determination of fuel marker in petroleum products using GC-MS (GC-MS를 이용한 석유제품 중의 식별제 분석)

  • Youn, Ju Min;Doe, Jin Woo;Yim, Eui Soon;Lee, Jung Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1073-1080
    • /
    • 2018
  • There are several types of petroleum products used for the fuel oil, according to their respective quality standards, grades and usage. Depending on the degree of oil tax rate by country, even the same petroleum products will have price gap. The illegal mixing of cheap petroleum products, which are subject to the lower tax rate, with relatively expensive transportation fuel causes problems such as tax evasion, environmental pollution and vehicle breakdown. In order to prevent illicit production and mixing of these different petroleum products, a small amount of markers are legally added to specific petroleum products. In Korea, markers are introduced and used to prevent illegal activity that kerosene used as fuel for house and commercial boiler are mixed with automotive diesel fuels, and marker contents are analyzed to use UV-Vis spectrophotometer and high performance liquid chromatography (HPLC). In this study, we have developed a method to qualitatively and quantitatively determine the marker added to petroleum products by gas chromatography-mass spectrometry (GC-MS) without adding developing reagent or sample pre-treatments.