• Title/Summary/Keyword: gap measurement

Search Result 696, Processing Time 0.032 seconds

The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers (연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화)

  • Kim, Yong-Bae;Ahn, Hyun-Cheol;HwangBo, Young;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

Error Analysis of Image Velocimetry According to the Variation of the Interrogation Area (상관영역 크기 변화에 따른 영상유속계의 오차 분석)

  • Kim, Seojun;Yu, Kwonkyu;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.821-831
    • /
    • 2013
  • Recently image velocimetries, including particle image velocimetry (PIV) and surface image velocimetry (SIV), are often used to measure flow velocities in laboratories and rivers. The most difficult point in using image velocimetries may be how to determine the sizes of the interrogation areas and the measurement uncertainties. Especially, it is a little hard for unskilled users to use these instruments, since any standardized measuring techniques or measurement uncertainties are not well evaluated. Sometimes the user's skill and understanding on the instruments may make a wide gap between velocity measurement results. The present study aims to evaluate image velocimetry's uncertainties due to the changes in the sizes of interrogation areas and searching areas with the error analyses. For the purpose, we generated 12 series of artificial images with known velocity fields and various numbers and sizes of particles. The analysis results showed that the accuracy of velocity measurements of the image velocimetry was significantly affected by the change of the size of interrogation area. Generally speaking, the error was reduced as the size of interrogation areas became small. For the same sizes of interrogation areas, the larger particle sizes and the larger number of particles resulted smaller errors. Especially, the errors of the image velocimetries were more affected by the number of particles rather than the sizes of them. As the sizes of interrogation areas were increased, the differences between the maximum and the minimum errors seemed to be reduced. For the size of the interrogation area whose average errors were less than 5%, the differences between the maximum and the minimum errors seemed a little large. For the case, in other words, the uncertainty of the velocity measurements of the image velocimetry was large. In the viewpoint of the particle density, the size of the interrogation area was small for large particle density cases. For the cases of large number of particle and small particle density, however, the minimum size of interrogation area became smaller.

Adaptability of zirconia core fabricated by cold isostatic pressing (냉간 정수압 성형법으로 제작된 지르코니아 코어의 적합도에 관한 연구)

  • Seo, Yoon-Jeong;Yun, Kwi-Dug;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.143-150
    • /
    • 2010
  • Purpose: The purpose of this study is to fabricate the new zirconia block (CNU block) and to evaluate fit of core and porcelain veneered zirconia crown. Material and methods: The experimental blocks were fabricated from the commercial ytrria-stabilized zirconia powder (KZ-3YE Type A). The powder was uniaxial pressing and the green bodies were conducted using the Cold Isostatic Pressing. The zirconia blocks were presintered at $1040^{\circ}C$ and the final sintering was performed at $1450^{\circ}C$. The Kavo Everest ZS $blank{(R)}$ (KaVo, Biberach/ $Ri{\beta}$.) was used as a control group. The linear shrinkage of CNU block and Kavo block were compared. Twenty-one cores for porcelain veneered crowns were fabricated with CAD/CAM system ($Everest{(R)}$, Biberach/ $Ri{\beta}$.). Group I; seven cores fabricated from Kavo blocks, Group II; seven cores fabricated from CNU blocks, Group III; seven cores from CNU blocks and porcelain veneering for crowns. All specimens were cemented and sectioned into two planes; diagonal and bucco-lingual. The measurement of the marginal, internal, and occlusal fit was carried out using SEM ($S-4800^{(R)}$) at $30{\times}$. The results were analyzed by one-way ANOVA test. Results: The linear shrinkage of the CNU block and the KaVo block was 19.00% and 20.09%. The marginal gap of cores ($29.67{\pm}6.58{\mu}m$) fabricated from CNU blocks showed significantly smaller than that of the cores of Kavo blocks ($36.84{\pm}7.18{\mu}m$) (P < .05). The internal gaps of the porcelain veneered crowns ($32.23{\pm}6.33{\mu}m$) were larger than those of the other two groups ($37.57{\pm}6.81{\mu}m$ and $38.14{\pm}6.81{\mu}m$). Conclusion: No statistically significant difference was found in between experimental groups and control group. The experimental groups in marginal gap showed significantly smaller than the control group.

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Fabrication of Schottky Device Using Lead Sulfide Colloidal Quantum Dot

  • Kim, Jun-Kwan;Song, Jung-Hoon;An, Hye-Jin;Choi, Hye-Kyoung;Jeong, So-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.189-189
    • /
    • 2012
  • Lead sulfide (PbS) nanocrystal quantum dots (NQDs) are promising materials for various optoelectronic devices, especially solar cells, because of their tunability of the optical band-gap controlled by adjusting the diameter of NQDs. PbS is a IV-VI semiconductor enabling infrared-absorption and it can be synthesized using solution process methods. A wide choice of the diameter of PbS NQDs is also a benefit to achieve the quantum confinement regime due to its large Bohr exciton radius (20 nm). To exploit these desirable properties, many research groups have intensively studied to apply for the photovoltaic devices. There are several essential requirements to fabricate the efficient NQDs-based solar cell. First of all, highly confined PbS QDs should be synthesized resulting in a narrow peak with a small full width-half maximum value at the first exciton transition observed in UV-Vis absorbance and photoluminescence spectra. In other words, the size-uniformity of NQDs ought to secure under 5%. Second, PbS NQDs should be assembled carefully in order to enhance the electronic coupling between adjacent NQDs by controlling the inter-QDs distance. Finally, appropriate structure for the photovoltaic device is the key issue to extract the photo-generated carriers from light-absorbing layer in solar cell. In this step, workfunction and Fermi energy difference could be precisely considered for Schottky and hetero junction device, respectively. In this presentation, we introduce the strategy to obtain high performance solar cell fabricated using PbS NQDs below the size of the Bohr radius. The PbS NQDs with various diameters were synthesized using methods established by Hines with a few modifications. PbS NQDs solids were assembled using layer-by-layer spin-coating method. Subsequent ligand-exchange was carried out using 1,2-ethanedithiol (EDT) to reduce inter-NQDs distance. Finally, Schottky junction solar cells were fabricated on ITO-coated glass and 150 nm-thick Al was deposited on the top of PbS NQDs solids as a top electrode using thermal evaporation technique. To evaluate the solar cell performance, current-voltage (I-V) measurement were performed under AM 1.5G solar spectrum at 1 sun intensity. As a result, we could achieve the power conversion efficiency of 3.33% at Schottky junction solar cell. This result indicates that high performance solar cell is successfully fabricated by optimizing the all steps as mentioned above in this work.

  • PDF

Comparative Characteristics of Gold-Gold and Gold-Silver Nanogaps Probed by Raman Scattering Spectroscopy of 1,4-Phenylenediisocyanide

  • Kim, Kwan;Choi, Jeong-Yong;Shin, Dong-Ha;Lee, Hyang-Bong;Shin, Kuan-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.spc8
    • /
    • pp.2941-2948
    • /
    • 2011
  • A nanogap formed by a metal nanoparticle and a flat metal substrate is one kind of "hot site" for surface-enhanced Raman scattering (SERS). The characteristics of a typical nanogap formed by a planar Au and either an Au and Ag nanoparticle have been well studied using 4-aminobenzenethiol (4-ABT) as a probe. 4-ABT is, however, an unusual molecule in the sense that its SERS spectral feature is dependent not only on the kinds of SERS substrates but also on the measurement conditions; thus further characterization is required using other adsorbate molecules such as 1,4-phenylenediisocyanide (1,4-PDI). In fact, no Raman signal was observable when 1,4-PDI was selfassembled on a flat Au substrate, but a distinct spectrum was obtained when 60 nm-sized Au or Ag nanoparticles were adsorbed on the pendent -NC groups of 1,4-PDI. This is definitely due to the electromagnetic coupling between the localized surface plasmon of Au or Ag nanoparticle with the surface plasmon polariton of the planar Au substrate, allowing an intense electric field to be induced in the gap between them. A higher Raman signal was observed when Ag nanoparticles were attached to 1,4-PDI, irrespective of the excitation wavelength, and especially the highest Raman signal was measured at the 632.8 nm excitation (with the enhancement factor on the order of ${\sim}10^3$), followed by the excitation at 568 and 514.5 nm, in agreement with the finite-difference timedomain calculation. From a separate potential-dependent SERS study, the voltage applied to the planar Au appeared to be transmitted without loss to the Au or Ag nanoparticles, and from the study of the effect of volatile organics, the voltage transmission from Au or Ag nanoparticles to the planar Au also appeared as equally probable to that from the planar Au to the Au or Ag nanoparticles in a nanogap electrode. The response of the Au-Ag nanogap to the external stimuli was, however, not the same as that of the Au-Au nanogap.

Sol-Gel Synthesis, Crystal Structure, Magnetic and Optical Properties in ZnCo2O3 Oxide

  • Das, Bidhu Bhusan;Barman, Bittesh
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.453-458
    • /
    • 2019
  • Synthesis of ZnCo2O3 oxide is performed by sol-gel method via nitrate-citrate route. Powder X-ray diffraction (XRD) study shows monoclinic unit cell having lattice parameters: a = 5.721(1) Å, b = 8.073(2) Å, c = 5.670(1) Å, β = 93.221(8)°, space group P2/m and Z = 4. Average crystallite sizes determined by Scherrer equation are the range ~14-32 nm, whereas SEM micrographs show nano-micro meter size particles formed in ZnCo2O3. Endothermic peak at ~798 K in the Differential scanning calorimetric (DSC) trace without weight loss could be due to structural transformation and the endothermic peak ~1143 K with weight loss is due to reversible loss of O2 in air atmosphere. Energy Dispersive X-ray (EDX) analysis profile shows the presence of elements Zn, Co and O which indicates the purity of the sample. Magnetic measurements in the range of +12 kOe to -12 kOe at 10 K, 77 K, 120 K and at 300 K by PPMS-II Physical Property Measurement System (PPMS) shows hysteresis loops having very low values of the coercivity and retentivity which indicates the weakly ferromagnetic nature of the oxide. Observed X-band EPR isotropic lineshapes at 300 K and 77 K show positive g-shift at giso ~2.230 and giso ~2.217, respectively which is in agreement with the presence of paramagnetic site Co2+(3d7) in the oxide. DC conductivity value of 2.875 ×10-8 S/cm indicates very weakly semiconducting nature of ZnCo2O3 at 300 K. DRS absorption bands ~357 nm, ~572 nm, ~619 nm and ~654 nm are due to the d-d transitions 4T1g(4F)→2Eg(2G), 4T1g(4F)→4T1g(4P), 4T1g(4F)→4A2g(4F), 4T1g(4F)→4T2g(4F), respectively in octahedral ligand field around Co2+ ions. Direct band gap energy, Eg~ 1.5 eV in the oxide is obtained by extrapolating the linear part of the Tauc plot to the energy axis indicates fairly strong semiconducting nature of ZnCo2O3.

Study on Developing Instrument System for Measuring Action time of K4 Grenade Machine Gun for Improving Quality Assurance on 40mm High Velocity Grenade (40mm 고속유탄의 품질보증 향상을 위한 K4 기관총의 Action Time 계측시스템 개발에 관한 연구)

  • Hong, Sung-Kook;Shin, Jun-Goo;Jeon, Hye-Jin;Kim, Yong-Hwa;Ju, Jin-Chun;Kwon, In-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4828-4834
    • /
    • 2015
  • From the moment that a firing pin triggers the detonator to the moment that a grenade leaves a barrel is called Action Time. Since a loading and percussion of 40mm grenade happens simultaneously, action time should be within a certain time in order to prevent a Jamming malfunction. Previously, unreliable action time device of 40mm grenade made it difficult to improve quality assurance of K4 Grenade Machine Gun. Here, various sensors were compared and a special device was designed to seek an accurate measurement on action time. In this device, the gap between a signal from an optical sensor in Firing Pin and that from Eddy current probe in the barrel was recorded and data were sent to a computer in real time. Confirming if action time is within the criteria, it is expected that action time plays an important role in quality assurance on 40mm grenade.

Synthesis of Doped Polymethylphenylsilane Conductive Polymers and their Structure Characteristics (포리메틸페닐실란계 전도성 고분자의 합성과 구조 특성)

  • Yang, Hyun-Soo;Kang, Phil-Hyun;Kim, Jeong-Soo;Ryu, Hae-il;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.954-962
    • /
    • 1996
  • Four kind of polysilanes which had side chains of methyl, phenyl, and mixed structures, were synthesized and modified by doping with iodine. The structural, thermal, and electric characteristics of obtained polymers were systematically observed with iodine, The structural, thermal, and electric characteristics of obtained polymers were systematically observed with FT-IR, UV/VIS, TGA/DTG, DSC, and measurement of electric conductivity. From FT-IR spectra, it was confirmed that the synthesized polysilanes had side chains of methyl, phenyl, and mixed structures. The thermal stabilities of the polymers were found to increase with phenyl substituents. The polysilanes with phenyl side groups showed ${\sigma}-{\sigma}*$ transition absorption at wavelengths longer than 350 nm. The bathochromic shift of polysilanes with phenyl substituents relates probably to the narrowed band gap caused by delocalization of ${\pi}$-electron. The polymers doped with iodine showed multi-step pyrolysis behavior and higher residue compared with that of the undoped polymers. The electric conductivities of the undoped and doped polysilanes were $10^{-5}S/cm$ and $10^{-4}S/cm$, respectively.

  • PDF