• Title/Summary/Keyword: gap measurement

Search Result 700, Processing Time 0.029 seconds

Measurement of Cell Gap of Reflective LCD and Study of :Error Rate (반사형 LCD의 Cell Gap 측정 및 오차율 연구)

  • 이서헌;박원상;이기동;김재창;윤태훈
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.142-143
    • /
    • 2001
  • Cell gap은 LCD(Liquid Crystal Display)의 중요한 파라미터들 중의 하나이다. cell gap이 LCD의 광학적인 성능에 영향을 주기 때문에 정확한 cell gap 측정방법은 제조공정을 향상시키는데 중요하다 특히 최근 고속 영상 디스플레이를 제공할 수 있는 장점 때문에 낮은 cell gap의 LCD가 요구되고 있는 시장 추세에 따라 낮은 cell gap을 측정할 수 있는 기술이 요구되고 있다. LCD의 cell gap 측정 방법들 가운데 가장 보편화되어 있는 것으로 회전편광자법(rotating polarizer method)[1, 2]과 위상보상법(phase compensation method)[3,4]을 들 수 있는데 낮은 셀갭을 정확히 측정하기가 어려우며 주기적인 해가 발생한다는 단점이 있다. (중략)

  • PDF

DEVELOPMENT OF AN IMPROVED INSTALLATION PROCEDURE AND SCHEDULE OF RVI MODULARIZATION FOR APR1400

  • Ko, Do-Young
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.89-98
    • /
    • 2011
  • The construction technology for reactor vessel internals (RVI) modularization is one of the most important factors to be considered in reducing the construction period of nuclear power plants. For RVI modularization, gaps between the reactor vessel (RV) core-stabilizing lug and the core support barrel (CSB) snubber lug must be measured using a remote method from outside the RV. In order to measure RVI gaps remotely at nuclear power plant construction sites, certain core technologies must be developed and verified. These include a remote measurement system to measure the gaps between the RV core-stabilizing lug and the CSB snubber lug, an RVI mockup to perform the gap measurement tests, and a new procedure and schedule for RVI installation. A remote measurement system was developed previously, and a gap measurement test was completed successfully using the RVI mockup. We also developed a new procedure and schedule for RVI installation. This paper presents the new and improved installation procedure and schedule for RVI modularization. These are expected to become core technologies that will allow us to shorten the construction period by a minimum of two months compared to the existing installation procedure and schedule.

Measurement of Nursing Service Quality using SERVQUAL Model (SERVQUAL 모델을 이용한 간호 서비스 질 측정)

  • Lim, Ji-Young;Kim, So-In
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.2
    • /
    • pp.259-279
    • /
    • 2000
  • This study is a descriptive analytic research measuring nursing service quality, using SERVQUAL model, to make fundamental data and strategies for nursing service improvement. Data were collected by self-reported questionnaire from 202 patients and 142 nurses, from June 7 to 14, 1999. The reliability of instrument were adequate(Cronbach ${\alpha}=.94$). SAS program was utilized for statistical analysis of collected data. The results were as follows; 1. There was a gab between patient's expectation and perception on nursing service(Gap B). Gap D was indicated an affecting factor to decide nursing service quality. Gap C was indicated an indirect affecting factor of nursing service quality. Because it was not statistically significant in total item analysis, but in individual item analysis, 7 items were appeared statistically significant. Gap A was not a gap occurrence factor of nursing service quality. 2. Focuses of nursing service quality improvement strategies were; (1) to direct qualitative improvement of nursing service in order to correspondence patient's nursing service expectation. (2) to make nurse's service activity modified because nurse's practice were not reached patient's expectation level. (3) to need internal, external factor analysis affecting nurse's service activity. 3. Nursing service quality was decided by rather environmental inappropriateness provided nursing service than itself. Therefore, to make nursing service quality improvement, it is required to improve nursing service environment. For this, followings are required; (1) to strengthen nurse's education on lower part of nursing service satisfaction and QI activities. (2) to balance demand and supply of nursing personnel. 3) to fix computerized system for reducing other duties weight except nursing care through analysis of nursing activity. (4) to construct rational cooperating system among related departments. 4. The important parts for nursing service quality improvement were indicated as follows: (1) Gap B: 'prompt reaction', 'examination symptom before patient's complaint', 'hearted nursing service reducing patient's dissatisfaction', 'explanation goals of nursing activities', 'having special Knowledge enough', 'maintenance position comfortably', 'management of patient's physical hygiene'. (2) Gap C: 'maintenance physical safety', 'explanation about hospital rules and facilities'. (3) Gap D: 'tender, safe injection and wound care'. Because above items are mostly improved through nurse's attitude change and quality improvement, it is required to establish nursing standardization and to strengthen nurse's clinical education. As the based on above results, followings are suggested; 1. SERVQUAL model is very useful to make strategies for nursing service quality improvement because it indicates multiple factors affecting hap occurrence. 2. At individual items analysis of Gap C, statistically significant 7 items appeared higher nurse's perception level than patient's perception level on nursing service were trouble perception level on nursing service quality improvement. So. it need further research to analysis about these difference occurring factors. 3. At analysis of Gap D, it is indicated that in nursing service performance process, multiple factors lowing nursing service quality were intruded. So it needs further research to analysis what these factors are and how each factors affect on nursing performance process. 4. nursing service quality measurement is changeable according to sample select time or sampled subject's characteristics. So to develope strategy for nursing service quality improvement is based on the results of periodical analysis.

  • PDF

Implementation of an Auditory Late Latency Response Measurement System for Researching Objective Tinnitus Detection Method (객관적 이명검사 연구를 위한 청성 후기 반응 측정 시스템의 구현)

  • Park, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Recently, a method for detecting animal tinnitus objectively, gap prepulse inhibition of acoustic startling (GPIAS) were reported. However, the GPIAS method is difficult to be directly applied to human tinnitus research because measuring repeatedly startling responses evoked by more than 110 dB SPL acoustic stimuli for human is not easy. In this paper, the auditory late latency response (ALLR) measurement system which can measure conveniently evoked potentials involving the information about the brain cortical activity related with auditory psychologic phenomena such as a tinnitus has been implemented. By using the implemented system, 8 persons with normal hearing sense have been experimented to measure N1-P2 amplitudes of ALLRs evoked by gap prepulse based acoustic stimuli. Through the experimental results, the prepulse inhibitions of all the participants' N1-P2 responses have been observed and their characteristics were evaluated. And it is verified that our implemented system can be utilized as a device for researching and evaluating the objective tinnitus detection method in the future study.

  • PDF

A Study on the Measurement Error Induced by Air Gap of Electromagnetic Wave Absorber in the Coaxial Line Method (동축선법을 이용한 전파흡수체 특성 측정시 Air Gap에 의한 오차에 대한 연구)

  • 김경용;김왕섭;주윤돈;김병호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.874-879
    • /
    • 1991
  • The effect of air gap between specimen and jig on the material constant (permittivity, permeability) and attenuation characteristics of electromagnetic wave absorbers in the coaxial line method was investigated. The presence of a air gap made both permittivity and permeability measured lower than true value, and the tendency was greater in the case of permittivity. An inner gap compared to an outer gop was found to yield a larger difference between measured and true values. The effect of air gap was measured for a Ni0.3Zn0.7Fe2O4, with the gap eliminated by metallizing with Ag-paste. The measured characteristics were in good agreement with corrected values by calculation.

  • PDF

Fine Gap Control System Design Using Pneumatics servo System

  • Kim, Dong-Hwan;Kim, Young-Jin;Jeong, Dae-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.111.2-111
    • /
    • 2001
  • The research focuses on controlling a gap to measure the surface defect in semi-conductor fabrication device. The measurement is available accompanying a near field image gap control. In this article, a pneumatic servo system is adopted for the near field gap control. The advantage of the pneumatic servo system is on the preventing the possibility of contacting the device to the wapper surface, fence arising fatal damage. Furthermore, the air from the pneumatic system blows the some particle on the wapper during controlling. The target gap is less than 20 $\mu$m and the gap should keep same amount while the device moves around the surface. The experiment by the pneumatic servo control system is done by employing a simple PID control, and the tracking performance is remarkably verified. The target gap is set from 10 $\mu$m to 100 $\mu$m ...

  • PDF

Development of a Microscopic Gap Measuring Algorithm with a Fuzzy-RANSAC (퍼지란삭을 이용한 미소 거리 측정 알고리즘 개발)

  • Kim, Jae-Hoon;Park, Seung-Kyu;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1545-1546
    • /
    • 2008
  • In this study, an image processing method with FRANSAC(Fuzzy RANSAC) is presented and discussed for the development of a microscopic gap measuring algorithm. Many problems in edge detection processing are mainly occurred by the illumination system. A serious problem is that the edge set of gap could include the error elements that have relatively larger error than normal. This problem leads to a incorrect measurement of gap. We present a gap measuring algorithm using FRANSAC[1] that is a representative robust estimation algorithm. FRANSAC is peformed by first categorizing all data into good sample set, bad sample set and vague sample set using a fuzzy classification and then sampling in only good sample set. Experimental results show that the presented gap measuring algorithm gives a higher accurate value of gap especially for the more noisy image data.

  • PDF

A Study on the Gap Estimation Circuit Design of the Magnetic Levitation System (자기 부상계의 변위추정 회로설계에 관한 연구)

  • Kim, C.H.;Ha, Y.W.;Sim, S.H.;Yang, J.H.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.144-153
    • /
    • 1997
  • The magnetic levitation system is utilized in the magnetic bearing of high-speed rotor because of little friction, no lubrication, no noise and so on. The magnetic levitation system need the feedback controller for the stabilization of system, and gap sensors are generally used to measure the gap. The use of gap sensors brings out the increase of the number of troublesome, and the decrease of the control performance because of the dislocation between the measurement point and the control point. This paper presents the design of the gap estimation circuit for the sensorless method proposed by authors in the magnetic levitation system. We made the gap estimation circuit which was composed of both the superposition circuit and the measuring circuit. And we investigated the validity of the usefulness of the proposed sensorless method in the magnetic levitation system through results of actual experiment.

  • PDF

Analysis of the Shape of Gathered Skirts using a Three-Dimensional Measurement System (3차원 계측시스템을 이용한 개더스커트 형상 분석)

  • Jung Hee-Kyeong;Lee Myung-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.11
    • /
    • pp.1399-1409
    • /
    • 2005
  • The purpose of this study was to analyze the shape of gathered skirts using a three-dimensional measurement system. And in this experiment, I try to accumulate three-dimensional data of wearing model and to figure out analyzing method made by shape of clothes. The experimental design consists of two factorial designs. I set up three different kinds of fabrics, ratio of gathers. Therefore nine samples were made. The instrument and tools for three-dimensional measurement was whole body 3D scanner. Analysis program used in experiment is RapidForm 2004 PP1 and Pattern Design 2000. Data analysis utilizes SPSS WIN 10.0 Package. T-test to effect an inspection of evidence, there was difference about measurement times. One-way ANOVA to analysis effect of gather made by gathering conditions. The following results were obtained; 1. As a result of inspecting an error several times using a three-dimension measurement system, convinced data was obtained. 2. At front, distribution of gap amount was larger than back. And as ratio of gathers increased, distribution of gap amount showed regularly. 3. After analyzing horizontal sectional figure of skirts, as a height of skirt changed from waist to the bottom of skirts, the results showed as follows. While section width, section thickness, node width, node depth increased, node count decreased. 4. With the horizontal section levels of gather skirt, the silhouette on middle hip section was similar with the silhouette of body line. And as ratio of gathers around hip section increased, nodes showed regularly. At the bottom of skirts showed different nodes by different gathering condition.

Diagnosis of Performance Measurement System of Knowledge Management : A Case of University (대학 지식경영 성과측정시스템의 진단 사례연구)

  • Lee, Young-Chan;Lee, Seung-Seok
    • Knowledge Management Research
    • /
    • v.10 no.1
    • /
    • pp.71-100
    • /
    • 2009
  • Recently, many of organizations build up their performance measurement system (PMS) to measure their knowledge management performance. However, the system that doesn't well reflect the organization's strategies as well as surroundings could obstruct their performance improvement, instead. Therefore, It is really important to establish the PMS to reflect organization's surroundings and strategies. The purpose of this study is to make a diagnosis of a performance measurement practice of a domestic university's knowledge management. To serve this research purpose, we examine the uptight performance index and PMS from existing references. And we diagnose the specific practices and maturity rates of measuring performances, and the recognition of the performance index at "D" university recently adopting balanced scorecard to performance evaluation through the survey on academic affairs committee members, performance evaluation committee members, and administration members. The method analyzing data from the survey is a gap analysis which includes alignment analysis, congruence analysis, consensus analysis, and confusion analysis. We make a diagnosis of performance measurement practices at "D" university, raise several points of this performance measurement system, and present the improvement plans from these problems.

  • PDF