• Title/Summary/Keyword: gap measurement

Search Result 699, Processing Time 0.039 seconds

A study on the Observer Design of the Levitation System using Kalman Filter (칼만필터를 이용한 부상시스템 관측기 설계에 관한 연구)

  • Jo, Jeong-Min;Han, Y.J.;Lee, C.Y.;Lee, H.W.;Kang, B.B.;Lee, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1191_1192
    • /
    • 2009
  • The objective of levitation control design is to stabilize a levitation system, or obtain certain transient response, bandwidth, and steady state error. An air gap signal from the each corner is important parameter to design levitation controller. A levitation controller using gap signals with measurement delay time can not make a expected performance. In this paper, a new air gap estimator to improve the performance of levitation controller is proposed. The estimated gap signal which has little measurement delay time is used as a feedback value in the levitation controller.

  • PDF

Ultrasonic Measurement of Gap between Calandria Tube and Liquid Injection Nozzle in CANDU Reactor (초음파를 이용한 중수로내 칼란드리아관과 원자로 정지물질 주입관과의 간격 측정)

  • Sohn, Seok-Man;Kim, Tae-Rong;Lee, Jun-Sin;Lee, Young-Hee;Park, Chul-Hun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.834-839
    • /
    • 2001
  • Calandria tube wrapping each pressure tube is one of the key structural components of CANDU reactor(Calandria) which is consisted of many pressure tubes containing nuclear fuel assemblies. As the Calandria tube(made of zirconium alloy) is sagging due to its thermal and irradiation creep during the plant operation, it possibly contacts with liquid injection nozzle crossing beneath the Calandria tube, which subsequently results in difficulties on the safe operation. It is therefore necessary to check the gap for the confirmation of no contacts between the two tubes, Calandria tube and liquid injection tube, with a proper measure during the life of plant. In this study, an ultrasonic measurement method was selected among several methods investigated. The ultrasonic device being developed for the measurement of the gap was introduced and its preliminary performance test results were presented here. The gap between LIN and CT at site was measured using by this ultrasonic device at site.

  • PDF

A Comparative Study of a Variable Overlap-area Type and Conventional Types in the Inductive Precision Position Measurement System (자속경로 단면적 및 공극변화를 이용한 인던턴스형 초정밀 변위측정 시스템)

  • Choe, Dong-Jun;Choe, In-Muk;Kim, Su-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.254-259
    • /
    • 2002
  • A variable air-gap type system is widely used for inductive precision position measurement systems. This type transducer has high sensitivity but lacks a linear measurement range due to structural nonlinearity. Furthermore, as measurement range increases, linearity error is also increased. The alternative is a variable overlap-area type system. The sensitivity of this type is determined by the initial air-gap dimension, keeps the original value and does not deteriorate linearity in spite of the variations of the measuring range.

A Study of the Boring Bar Vibration Measurement using Optical Fiber Sensor (보링바 고유진동 계측을 위한 광섬유 진동센서 연구)

  • Song, Doo-Sang;Hong, Jun-Hee;Jeong, Hwang-Young;Kang, Dae-Hwa;Kim, Byung-In
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.107-113
    • /
    • 2009
  • In this paper, we studied of measurement the vibration of natural frequency using optical fiber sensor. The boring bar for measurement of vibration in use optical fiber sensor has the advantage of direct measure for the frequency than accelerometer. Because it deal with output value on electrical signal of optical fiber in physical disturbance when it measures the frequency of vibration. The optical fiber sensor measured the vibration of boring bar by the gap in sensing jig while optical fiber just kept contact with boring bar. A prototype system was composed of jig part with gap and optical system part. In this paper, we found out the possibility to measurement of vibration by the gap in use optical fiber.

A Comparison of High Frequency Properties of LTCC Substrate Systems (LTCC 기판 시스템의 고주파 특성 비교)

  • 이영신;김경철;박성대;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.7-12
    • /
    • 2002
  • In the measurement of the RF properties, the LTCC substrate must be considered as a system including various conductor patterning processes. In this paper, the LTCC substrate system is compared with a conventional PCB(Printed Circuit Board) substrate such as FR-4, Duroid and Teflon, etc. The microstrip resonator method is employed for the measurement of the RF properties in the range of DC to 20 GHz. Experimental results show that the ring resonator method is suitable for system loss measurement, and the series gap resonator method for dielectric constant measurement. The process of conductor patterning and its effect on the system loss were also studied.

  • PDF

Design of 0.6~6 GHz Ultra Wideband Quad-ridge Horn Antenna (0.6~6 GHz 초 광대역 쿼드릿지 혼 안테나 설계)

  • Choi, Cheoljin;Lee, Moonhee;Son, Taeho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.77-82
    • /
    • 2019
  • In this paper, a 0.6~6GHz quad-ridge horn antenna which can be used for the antenna measurement of 5.8GHz WiFi system from lowest frequency band of mobile LTE (Long Term Evolution) is designed and implemented. The quad-ridge horn antenna has quadruple ridges of exponential function, a back-short and a cavity. Based on this structure, we design the cavity size, ridge gap and feed gap to have broadband characteristics. For implementation, the plates material of aluminum and copper are used for the horn and four ridges, respectively. And the insulator supports are used to maintain the gap between ridges. By measurement, antenna has the gain of 6.2~13.35dBi with the return loss of less than -6dB (under VSWR 3 : 1) in the entire design band. The results of this study can be widely used to the antenna studies on the mobile communication including low frequency band of LTE, the EMI measurement and the standard calibration measurement.

A Study on a Displacement Measurement Method of Magnetic Levitation System Applying the Inductance Characteristic (인덕턴스 특성을 이용한 자기부상계의 변위 측정의 한 방법에 관한 연구)

  • 김창화;양주호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.95-99
    • /
    • 1996
  • In this paper, we proposed a method to measure the gap between the magnetic pole and the levitated object applying the inductance characteristic which vary according to gap. We made a driving circuit which supply the control input PWM(Pulse Width Modulation) signal and the carrier PWM signal to estimate the gap. Because the inductance is a function of gap, and the current of the carrier signal is a function of the inductance. We investigated the validity of the proposed method through the experimental results.

  • PDF

A Study of Diffraction Effect on LCOS Microdisplay

  • Liu, Weimin;Liu, Joe;Liu, Vincent;Chiang, Wei Chen;Cheng, Hui Lun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.373-376
    • /
    • 2004
  • The measurement of diffraction of LCOS microdisplay with various pixel size, interpixel gap, pixel height and coatings demonstrates that pixel size is the leading factor for diffraction loss, while the role of varying pixel gap is less significant comparatively. One-dimensional diffraction simulation is found to be in good agreement with the measurement. Noticeable deviation occurs when pixel size is as small as 8um.

  • PDF

Displacement Sensorless Active Magnetic Bearing Control by Current Measurement (전류신호를 이용한 능동 자기 베어링계의 제어)

  • 권계시;정호섭;이종원
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 1995
  • An electronic circuit device is developed such that the displacement between an electromagnet and a moving target can be estimated from the coil current measurement, and then applied to an active magnetic bearing system. In order to levitate the shaft without using displacement sensor the stable control gains are obtained from the linearized model which includes the gap estimation circuit. Experimental results show that the shaft, by the estimated gap feedback, can be levitated within $\pm$6 ${\mu}m$ positioning error.

  • PDF

A Change in the Gap of the Shape of Gathered Skirts Made By Different Gatherings (개더스커트의 개더 구성방법에 따른 착의 공극량 변화)

  • Lee, Myung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.13 no.6
    • /
    • pp.959-966
    • /
    • 2004
  • The purpose of this research is to analyze the shape of gathered skirts made by different gatherings. The shape of gathered skirts is affected by the amount of the gatherings that control fullness along a waistline seam. The gap also has an effect on the shape. We made a few experiments to make gathered skirts in different gathering conditions. The conditions include two types of ratio of gathers, which were given the total amount of gathering, and two types of spread of gathers, which were calculated for waist and hip. Experiments were conducted to figure out the dressed shape through 3-D measurement Exyma- WBS, and also to investigate the proportion, area distribution, and gap of the shape of gathered skirts on the horizontal section map with Rapid Form 2004 SP3, a software for 3-D shape analysis. As the results show, there were differences among the proportion, area distribution, and gap of the dressed shape. It showed that the shape on the horizontal section map was different because the shape between waist and hip per parts on body was not the same.

  • PDF