• Title/Summary/Keyword: gap length

Search Result 657, Processing Time 0.021 seconds

THE DIMENSIONAL CHANGE OF CAST IMPLANT BARS AFTER LABORATORY PROCEDURE

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.354-361
    • /
    • 2007
  • Statement of Problems. The precision of fit between the bearing surfaces of implant abutments and the prosthesis framework has been considered fundamental to implant prosthodontic protocol. Purpose. The study aimed to investigate the effect of laboratory procedure on the dimensional accuracy of cast implant bars. Material and methods Thirty implant bars were fabricated on a metal master model. The gap distances were measured at the right implant abutment replica-gold cylinder interface after casting procedure. The bar length data of precasting and postcasting state were collected and analyzed. Results. The mean gap distance found after casting was $106.3{\mu}m$ for buccal side, $122.1{\mu}m$ for distal side and $117.1{\mu}m$ for the lingual side. The mean bar length was $17964.7{\mu}m$ at precasting measurement, $17891.6{\mu}m$ at postcasting measurement. The mean change of bar length was $-73.1{\mu}m$. Conclusion. Even though the techniques used in this study strictly followed the guidelines established in the literature, the 30 cast implant bars evaluated all yielded gap distances that were beyond acceptable accuracy. There was a statistically significant difference between precasting and postcasting bar length (P<0.01). There was a decreasing tendency in bar length after casting procedure. It was necessary to correct this dimensional change from laboratory procedure by some corrective methods.

A Study on the Exhaust Gas Recirculation in a MILD Combustion Furnace by Using the Coanda Nozzle Effect (MILD 연소로에서 Coanda 노즐 효과를 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.967-972
    • /
    • 2013
  • A MILD (Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow rate of hot exhaust gas to the combustion furnace. The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of coanda nozzle geometrical parameters, nozzle passage gap length, nozzle passage length, nozzle angle and expansion length. The optimal configuration of coanda nozzle for the best entrainment flow rate was gap length, 0.5 mm, expansion angle, 4o and expansion length, 146 mm. The nozzle passage length was irrelevant to the exhaust gas entrainement.

Experimental Studies on the Motion and Discharge Behavior of Free Conducting Wire Particle in DC GIL

  • Wang, Jian;Wang, Zhiyuan;Ni, Xiaoru;Liu, Sihua
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.858-864
    • /
    • 2017
  • This study aims to restrain free conducting wire-type particles which are commonly and dangerously existing within DC gas-insulated transmission lines. A realistic platform of a coaxial cylindrical electrode was established by using a high-speed camera and a partial discharge (PD) monitor to observe the motion, PD, and breakdown of these particles. The probabilities of standing or bouncing, which can be affected by the length of the particles, were also quantitatively examined. The corona images of the particles were recorded, and particle-triggered PD signals were monitored and extracted. Breakdown images were also obtained. The air-gap breakdown with the particles was subjected to mechanism analysis on the basis of stream theory. Results reveal that the lifting voltage of the wire particles is almost irrelevant to their length but is proportional to the square root of their radius. Short particles correspond to high bouncing probability. The intensity and frequency of PD and the micro-discharge gap increase as the length of the particles increases. The breakdown voltage decreases as the length of the particles decreases.

POOL BOILING HEAT TRANSFER IN A VERTICAL ANNULUS WITH A NARROWER UPSIDE GAP

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1285-1292
    • /
    • 2009
  • The effects of the narrowed upside gap on nucleate pool boiling heat transfer in a vertical annulus were investigated experimentally. For the study, a stainless steel tube with a diameter of 25.4 mm and saturated water that kept an atmospheric condition were used. The ratio between the gaps measured at the upper and the lower regions of the annulus ranged from 0.18 to 1. Two different lengths of the modified gap also were investigated. The change in heat transfer due to the modified gap became evident as the gap ratio decreased and the length of the gap increased. As the gap ratio became less than 0.51, a significant decrease in heat transfer was observed compared to the plain annulus. The longer gap size resulted in an additional decrease in heat transfer. The major cause for the tendency was attributed to the formation of lumped bubbles around the upper region of the annulus followed by the increased flow friction between the fluid and the surface around the modified gap.

A Study on the roll gap set-up at top-end in plate rolling using finite element analysis (유한요소해석을 이용한 후판 압연공정의 선단부 롤갭 설정연구)

  • Yim, H.S.;Jang, J.H.;Choi, M.K.;Seo, J.H.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.252-255
    • /
    • 2009
  • The roll gap set-up in the finishing mill is one of the most important technologies in the hot plate rolling process. As the target thickness can be obtained by the correct set-up of the roll gap, improving the roll gap set-up technology is very critical for plate thickness accuracy. The main cause of thickness variation in hot plate mills is the non-uniform temperature distribution along the length of the slab. The objective of this study is to adjust the roll gap set-up for the thickness accuracy of plate in hot rolling process considering top-end temperature drop. Therefore this study has concentrated on determining the correct amounts of roll gap to compensate thickness variation due to top-end temperature drop. The off-line simulation of compensated roil gap significantly decreases top-end thickness variation.

  • PDF

A Elicitation of Polynomial Equation of Thrust Coefficient for Linear Synchronous Motor by Experimental Design Method (영구자석의 overhang 길이 및 skew 효과를 고려한 LSM 추력함수 도출)

  • Jang, Ki-Bong;Pyo, Se-Ho;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1105-1109
    • /
    • 2009
  • This paper deals with a polynomial thrust equation of a permanent magnet linear synchronous motor that is considered by a skew and overhang effects of permanent magnet. The skew length, the overhang length, the width and height of permanent magnet, the teeth length and air-gap length which effect to the flux density of air-gap are selected as variables of the polynomial thrust equation. Polynomial thrust equation is elicited by the 6 parameters. The results are satisfied that the values by polynomial thrust equation are compared ones by using 3-dimensional finite element analysis and experiment.

A Study on Horizontal Fillet Welding by Using Rotating Arc (II) - Development of High-speed Welding Process - (회전아크를 이용한 수평필릿 용접에 관한 연구 (II) - 고속용접공정의 개발 -)

  • 김철희;나석주;이현철;김세환
    • Journal of Welding and Joining
    • /
    • v.21 no.3
    • /
    • pp.46-50
    • /
    • 2003
  • The horizontal fillet joint is one of the most important weld joints in the shipbuilding industry. High-speed rotating arc welding, which can increase the leg length, is an effective way to improve the weld productivity and quality for the horizontal fillet welding. Based on the Taguchi method, the effects of welding parameters on bead characteristics - leg length, asymmetry, undercut, overlap - are investigated fur high-speed welding process. As a result, the adequate welding parameters are selected for the required leg length, symmetric bead and no undercut. Besides, considerably consistent leg length is observed for the horizontal fillet welding with gap variation up to 3mm.

An Experimental Study of 3-D Axial Type Turbine Performance with Various Axial Gaps between the Rotor and Stator (축류형 터빈에서 정${\cdot}$동익 축방향 거리의 변화에 대한 실험적 연구)

  • Kim Jong-Ho;Kim Eun-Jong;Cho Soo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.541-544
    • /
    • 2002
  • The turbine performance test of an axial-type turbine is carried out with various axial gap distances between the stator and rotor. The turbine is operated at the low pressure and speed, and the degree of reaction is 0.373 at the mean radius. The axial-type turbine consists of ons-stage and 3-dimensional blades. The chord length of rotor is 28.2mm and mean diameter of turbine is 257.56mm. The power of turbo-blower for input power is 30kW and mass flow rate is $340m^3/min\;at\;290mmAq$ static-pressure. The RPM and output power are controlled by a dynamometer connected directly to the turbine shaft. The axial gap distances are changed from a quarter to two times of stator axial chord length, and performance curves are obtained with 7 different axial gaps. The efficiency is dropped about $5{\%}$ of its highest value due to the variation of axial gap on the same non-dimensional mass flow rate and RPM, and experimental results show that the optimum axial gap is 1.0-1.5Cx.

  • PDF

An Analysis on the Discharge Characteristics through 1-D Numerical Simulation in an AC PDP (AC PDP에서 1차원 수치해석을 통한 방전 특성 연구)

  • Lee, J.H.;Seo, J.H.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.220-222
    • /
    • 2003
  • In this paper, we analyze on the discharge characteristics through 1-D simulations in an at plasma display panel discharge cell. The model is based on a Poisson' equation, continuity and drift-diffusion equation. Results are presented in a 95% neon, 5% xenon gas mixture, for a gap length of 100us and a gas pressure of 400Torr at ambient temperature. Results for other gap length are also discussed. As a result, an increase of the gap cause increase of luminous efficiency but with larger sustaining voltage.

  • PDF

Characteristics of acoustic emission according to variation gap length on artificial needle shape void (인공적 침상보이드의 갭길이 변화에 따른 음향방출 특성)

  • 박재준;김상남
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.495-503
    • /
    • 1995
  • As lengthen gap leng of artificial needle shape void 0.24.rarw.1.5[mm]), the amplitude of AE(Acoustic Emission) pulses was enlarged and number of pulses be generated was few. The longer gap length of void, the shorter breakdown time. As a result of this, I found that existen of void in insulation mate was fatal deterioration of insulation. According to phase angle of applied voltage, time being void was scattered largely in region of phase angle of pulses of origination in phase angle of applied voltage. The result will be used to analysis of void diagnosis.

  • PDF