• Title/Summary/Keyword: gamma-ray measurement

Search Result 208, Processing Time 0.033 seconds

Search for the activity measurement of radionuclides I-131 (131I을 이용한 방사능 측정에 관한 연구)

  • Baek, Seong-Min;Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • Iodine is one of important nuclides to be checked for radiation exposure after nuclear power facility accidents. After Chernobyl accident, it was observed that there is a greater amount of organic iodine in the atmosphere than inorganic iodine. In this study, we not only varied the amount of sample being exposed to $^{131}I$ and the duration of exposure to $^{131}I$ but also diluted the sample in distilled water and mixed the sample in kelp and liquid $^{131}I$ to measure and analyze the radiation detection levels. We concluded that the radiation levels were not high enough to be harmful to human body. The radiation from $^{131}I$ decreased over time, and we calculated the half life at 7-9 days. We found that the radiation from any sample containing $^{131}I$ was halved by up to 7days.

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

Study on Measurements in Thyroid Uptake Rate Test (갑상선섭취율검사시(甲狀腺攝取率檢査時) 측정조건(測定條件)에 관(關)한 조사연구(調査硏究))

  • Kyong, Kwang-Hyon;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 1981
  • This study was conducted, during the period of 20-30th, July in 1981, to survey measurement methods in thyroid uptake rate test in Seoul city. The results were summarized as follows: 1. For the great part of nuclear medcine department, a mount of radioiodine($^{131}I$) administrated to the patients was $50-100{\mu}Ci$ in thyroid uptake rate test. 2. Distribution of scintillation, counter with crystal size of $1\frac{1}{2}inch$ was 43%, 3inch(22%), 2.5inch(14%) and $2\frac{1}{2}inch$ was 7% in RAI uptake rate test. 3. When RAI uptake rate test was performed, distribution of collimator in use was flat field type collimator(78%) in general and cylindrical type collimator was 22%. 4. High voltage applied to the P-M tube was $900{\sim}1000V$(50%) and most units provided $3{\sim}15%$ of the window range for the $^{131}I$ peak $\gamma-ray$ energy. 5. Distribution on the use of neck phantom for measurements standard solution was 57% and distribution of b filter in use for room background counts and extrathyroidal tissue was 43% and 50%. 6. The distance between the counter and the source was 25cm(58%) in measuring radioactivity of standard solution, thyroid tissue and background radioactivity count. 7. The early uptake measurements(2, 4, 6 hours) are done after administration of the radioiodine dose and also 24-hour and 48-hour uptake measurements are done in routine test.

  • PDF

Preparation and Characterization of Ordered Perovskite (CaLa) (MgMo) $_6$

  • Choy, Jin-Ho;Hong, Seung-Tae;Suh, Hyeong-Mi
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.6
    • /
    • pp.345-349
    • /
    • 1988
  • The polycrystalline powder of (CaLa) (MgMo)$O_6$ has been prepared at $1350^{\circ}C$ in $H_2/H_2O$ and $N_2$ flowing atmosphere. The powder X-ray diffraction pattern indicates that (CaLa) (MgMo)$O_6$ has a monoclinic perovskite structure with the lattice constants $a_0=b_0=7.901(1){\AA}$, $c =7.875(1){\AA}\;and\;{\gamma}=89^{\circ}$16'(1'), which can be reduced to orthorhombic unit cell, a = 5.551(1) ${\AA}$, b = 5.622(1) ${\AA}$ and c = 7.875(1) ${\AA}$. The infrared spectrum shows two strong absorption bands with their maxima at 590($ν_3$) and 380($ν_4$) cm, which are attributed to $2T_{1u}$ modes indicating the existence of highly charged molybdenum octahedron $MoO_6$ in the crystal lattice. According to the magnetic susceptibility measurement, the compound follows the Curie-Weiss law below room temperature with the effective magnetic moment 1.83(1)$_{{\mu}B}$, which is well consistent with that of spin only value (1.73 $_{\mu}_B$) for $Mo^{5+}$ with $4d^1$-electronic configuration within the limit of experimental error. From the thermogravimetric analysis, it has been confirmed that (CaLa) (MgMo)$O_6$ decomposes gradually into $CaMoO_4,\;MoO_3,\;MgO,\;La_2O_3$ and unidentified phases due to the oxidation of $Mo^{5+}$ to $Mo^{6+}$.

Parameter Analysis by Electron Spin Resonance Spectroscopy of Cellulose Radicals in Gamma-irradiated Dried Spicy Vegetables (방사선 조사 건조향신료의 ESR 측정에서 Cellulose Radical의 Parameter 분석)

  • Ahn, Jae-Jun;Kim, Dong-Gil;Chung, Hyung-Wook;Kwon, Joong-Ho
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.371-375
    • /
    • 2009
  • Electron spin resonance (ESR) spectroscopy was used to detect radiation-induced signals from irradiated spices and ESR parameters were analyzed to define specific signals. Four powdered spices (red pepper, garlic, onion, and black pepper) were irradiated with 0, 1, 5, or 10 kGy at room temperature using a [60Co] gamma-ray irradiator prior to ESR analysis. Radiation-induced triplet signals, including those from the cellulose radical, which are center signals ($g_2=2.00673$) within the range of 3.0455 mT, were observed in all irradiated spice samples. The parameters g-value, center field, and signal range of hyperfine triplet ESR signals were constant in all irradiated samples, being specific for cellulose radicals and thereby distinguishing these signals from those of nonirradiated control samples. High positive correlation coefficients ($R^2=0.8452-0.9854$) were obtained between irradiation doses and corresponding ESR signal intensities. Thus, reliable detection of irradiated dried spices by measurement of ESR cellulose signals was confirmed by parameter analysis for the cellulose radical.

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Evaluation of Radiation effective dose by Naturally Radionuclides in the Soil of Busan (부산지역 토양 내 천연방사성핵종 분석 및 유효선량율 평가)

  • Kim, Jung-Hoon;Kim, Chang-Soo;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3658-3666
    • /
    • 2014
  • The presence of $^{238}U$, $^{232}Th$ and $^{40}K$, which are naturally residing radionuclides, in the ordinary soil of Busan, the 2nd largest city in Korea, was anlayzed and the residents' radiation exposure to ordinary soil was evaluated. Regarding the measurement methods, to conduct a detailed analysis of the naturally residing radionuclides in the soil of Busan, this study divided the 16 administrative districts into a lattice structure with 3 spots, and collected a total of 48 soil samples (July 2012 and April 2013). ICP-MS was used to analyze the concentration of the radioactivity of $^{238}U$ and $^{232}Th$ in the soil, and a HpGe detector, a gamma ray detector, was used to analyze the radioactivity of $^{40}K$. The measurement values of this study were compared with the concentration of radioactivity of East Asian regions. The concentration of $^{238}U$ nuclides in Korea was lower than the mean, whereas the concentration of $^{232}Th$ and $^{40}K$ nuclides was higher than the mean. The higher mean concentrations of $^{232}Th$ and $^{40}K$ than the mean were attributed to the many granite areas that contain a great deal of naturally occurring radionuclides.

Detection Characteristics of PSL and TL Methods in Spices Irradiated with Different Radiation Sources (조사선원에 따른 향신료의 PSL과 TL 검지 특성)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Kim, Jung-Ki;Hwang, Cho-Rong;Lee, Jae-Hwang;Park, Yong-Chjun;Kim, Jae-I;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The detection characteristics of irradiated spices were investigated depending on radiation sources and doses by photostimulated luminescence (PSL) and Thermoluminescence (TL). 6 kinds of spices (turmeric, onion powder, red pepper, basil, parsley, black pepper) were irradiated at 0 to 10 kGy under ambient conditions by both a $^{60}Co$ gamma irradiator and an electron beam (EB) accelerator, respectively. The PSL analysis showed negative results for non-irradiated spices, while irradiated spices gave intermediate and positive value, which presented the limited potential of PSL technique. In TL measurement, TL glow curves on non-irradiated samples appeared at about $300^{\circ}C$ with low intensity. All irradiated samples were easily distinguishable through radiation-specific strong TL glow curves with maximum peak in range of $150{\sim}200^{\circ}C$. TL ratio ($TL_1/TL_2$) obtained by a re-irradiation step could verify the detection result of $TL_1$ glow curves, showing ratios lower than 0.1 in the non-irradiated sample and higher than 0.1 in irradiated ones. Therefore, in PSL measurement, the identification of irradiated spices showed more clear results in electron beam irradiated samples. TL analysis showed obvious difference between non-irradiated and irradiated samples in gamma ray and electron beam irradiated samples.

Usefulness of Interferon-$\gamma$ Measurement Following Stimulation of Tuberculosis-specific Antigens for Diagnosis of Latent Tuberculosis Infection in Children Exposed to Pulmonary Tuberculosis (폐결핵 접촉력을 가진 소아에서 잠복 결핵 감염의 진단을 위한 결핵 특이항원 자극 인터페론-감마 측정의 유용성)

  • Sung, Ji Yeon;Ki, Joo Hwa;Yang, Mi Ae;Kim, So Hee;Eun, Byung Wook;Kim, Nam Hee;Park, Kyoung Un;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.1
    • /
    • pp.52-58
    • /
    • 2008
  • Purpose : Whole blood interferon-$\gamma$ assay was developed and many studies showed its usefulness in diagnosing tuberculosis (TB) including latent tuberculosis infection (LTBI). However, assessment in children has been limited. This study was undertaken to evaluate the usefulness of QuantiFERON-TB Gold for the diagnosis of LTBI in children exposed to pulmonary TB. Methods : Children who visited Seoul National University Bundang Hospital with a history of TB exposure were enrolled from January 2006 to December 2007. They were evaluated with chest x-rays, tuberculin skin test (TST) and QuantiFERON-TB Gold test. TST was retested 3 months later for those with initial negative reactivity. Definition of LTBI was made on the basis of the TST reactivity. Results : Among the 103 children with a history of TB exposure, 49 children were tested with chest x-ray, TST, and QuantiFERON-TB Gold. Twenty-two were males. Median age was 7.5 years (range; 3 months to 14.7 years). According to TST reactivity, LTBI was in 8 (19%), no infection was in 21 (50%), possible LTBI was in 13 (31%). QuantiFERON-TB Gold test was positive in 5 of the 49 subjects (10%); 3 of the 13 subjects (23.1%) in unknown status, 1 of the 8 subjects (13%) in LTBI, and 1 of the 21 subjects (5%) without infection. The agreement between the QuantiFERON-TB Gold and the TST was poor (${\kappa}=0.101$). Conclusion : QuantiFERON-TB Gold showed poor sensitivity for the diagnosis of LTBI in children with exposure to TB. QuantiFERON-TB Gold alone does not seem to be useful in the diagnosis of LTBI in children.

  • PDF