• Title/Summary/Keyword: gamma tool

Search Result 170, Processing Time 0.029 seconds

Influence of Void on Performance of Industrial SPECT System (공정 내 기포가 산업용 SPECT의 성능에 미치는 영향)

  • Park, Jang Guen;Jung, Sung-Hee;Kim, Jong Bum;Moon, Jinho;Kim, Chan Hyeong
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Industrial single photon emission computed tomography (SPECT) is an useful technique to investigate the dynamic behavior of process flow. In the present study, to evaluate the influence of a void on the performance of industrial SPECT, industrial SPECT with various radioisotope sources and gas holdups was modeled by the Monte Carlo simulation. The results are very encouraging; that is, the void little influences the performance of industrial SPECT, which means that industrial SPECT could be a suitable tool to investigate the dynamic characteristics of the flow in a water-air phase process.

True coincidence summing correction factor for point source geometry with PHITS

  • Esra Uyar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4472-4476
    • /
    • 2023
  • In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/calculated in gamma-ray spectrometric studies.

Effect of gamma irradiation on the color values and physiological properties of spent coffee ground extraction (감마선 조사가 커피박 추출물의 색도 및 생리활성에 미치는 영향)

  • Song, Ha-Yeon;Kim, Hye-Min;Kim, Woo Sik;Yang, Mi-So;Byun, Eui-Hong;Jang, Beom-Su;Choi, Dae Seong;Byun, Eui-Baek
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.544-549
    • /
    • 2017
  • The spent coffee grounds (SCG) are considered valuable by-products because they contain various bioactive compounds. The SCG extraction (SCGE) was irradiated at doses ranging between 30 and 50 kGy. The deep dark-brown color of SCGE was changed to a bright yellow color by gamma irradiation. The content of the bioactive compounds of gamma-irradiated SCGE was analyzed by high-performance liquid chromatography. Interestingly, the content of quinic acid was increased by gamma irradiation, whereas other compounds were decreased. Although the contents of bioactive compounds were changed by gamma irradiation, the biological activities (radical scavenging activity and whitening effects) of SCGE were unaffected. Our findings suggest that gamma irradiation can effectively improve the color values of SCGE without the loss of biological activities. Consequently, gamma irradiation can be a useful tool for improving the utilization of SCGE in the cosmetic industry.

Current Issues for the Material Balance Evaluation in NFFP

  • Na, Won-Woo;Park, Wan-Sou;Ahn, Seung-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.1447-1448
    • /
    • 2004
  • As the plants are classified as a bulk facility by the Agency's safeguards criteria, the Material Balance Evaluation is a good tool to timely detect diversion that will be accomplished through the creation of defects as small as bias defects. Through all evaluations made by the Agency, it Is strongly recommended to report SRD based on both weight and enrichment, maintain the reliable MUF declaration and improve the gamma spectrometry measurement procedure. These recommendations have been now applied and are going on.

  • PDF

Clinical Application of Gamma Knife Dose Verification Method in Multiple Brain Tumors : Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Lee, Jae Min;Cho, Won Ho;Kang, Dong Wan;Kim, Choong Rak;Choi, Byung Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.102-107
    • /
    • 2013
  • Objective : The Leksell Gamma Knife$^{(R)}$ (LGK) is based on a single-fraction high dose treatment strategy. Therefore, independent verification of the Leksell GammaPlan$^{(R)}$ (LGP) is important for ensuring patient safety and minimizing the risk of treatment errors. Although several verification techniques have been previously developed and reported, no method has ever been tested statistically on multiple LGK target treatments. The purpose of this study was to perform and to evaluate the accuracy of a verification method (modified variable ellipsoid modeling technique, MVEMT) for multiple target treatments. Methods : A total of 500 locations in 10 consecutive patients with multiple brain tumor targets were included in this study. We compared the data from an LGP planning system and MVEMT in terms of dose at random points, maximal dose points, and target volumes. All data was analyzed by t-test and the Bland-Altman plot, which are statistical methods used to compare two different measurement techniques. Results : No statistical difference in dose at the 500 random points was observed between LGP and MVEMT. Differences in maximal dose ranged from -2.4% to 6.1%. An average distance of 1.6 mm between the maximal dose points was observed when comparing the two methods. Conclusion : Statistical analyses demonstrated that MVEMT was in excellent agreement with LGP when planning for radiosurgery involving multiple target treatments. MVEMT is a useful, independent tool for planning multiple target treatment that provides statistically identical data to that produced by LGP. Findings from the present study indicate that MVEMT can be used as a reference dose verification system for multiple tumors.

Development of radioactive prospecting as tool for evaluating degree of granitic rocks weathering

  • Ishida Satoshi;Tsuchihara Takeo;Imaizumi Masayuki;Ohnishi Ryouichi
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.416-421
    • /
    • 2003
  • To develop an easy, low-cost method for evaluating the degree of weathering by radioactive prospecting, radioactive prospecting and the investigation of the degree of weathering were carried out in the southern Kitakami massif of Iwate Prefecture, Japan, in which weathering granitic rocks was distributed. Fifty outcrops in the study area were selected, and strength of the gamma-rays emitted from the weathering bedrock of $^{40}K,\;^{214}Bi,\;and\;^{208}Tl$ was measured for 15 minutes at each point. At the same points, soil hardness was measured on the surface of the outcrop with a Yamanaka soil penetration tester. In addition, 100cc samples of each outcrop were taken with the sampler. The samples were analyzed by XRD, and the kind of the rock-forming minerals containing K was identified. We then compared the degree of weathering and the radioactive prospecting results by using K as an indicator. The relation between $^{40}K/^{208}Tl$ gamma rays counting rate by the radioactive prospecting and the hardness index showed a positive correlation as a result of the investigation, and the correlation coefficient ($R^2$) was 0.67.Moreover, when $^{40}K/^{208}Tl$ gamma rays counting rate emitted from the bedrock was low, the number of rock-forming mineral species containing K was also low. Thus, it was found that $^{40}K/^{208}Tl$ gamma rays counting rate measured by the radioactive prospecting could be used as an indicator of the degree of weathering.

  • PDF

Desensitization of $A_1$ Adenosine Receptors in Rat Cerebral Cortex (흰쥐 대뇌피질에서 $A_1$ 아데노신 수용체의 탈감작)

  • Park, Kyung-Sun;Yang, Wan-Suk;Kim, Kyung-Hwan
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.2
    • /
    • pp.151-158
    • /
    • 1996
  • Following the subcutaneous administration of $R(-)N^6-(2-phenylisopropyl)adenosine(600\;nmol/kg/hr)$ to rats for 1 week using t$Alzet^{\circledR}$ mini-osmotic pumps, $A_1$ adenosine receptor functions were determined using $[^3H]DPCPX$ binding, $[^{35}S]GTP_{\gamma}S$ binding, and adenylyl cyclase assays. $A_1$ adenosine receptor binding and the inhibition of adenylyl cyclase activity by PIA was not altered in cerebrocortical membranes prepared from PIA-treated rats. However, there was a significant decrease in the $A_1$ adenosine receptor-mediated stimulation of $[^{35}S]GTP_{\gamma}S$ binding to cerebrocortical membranes prepared from PIA-treated rats(22.0% decrease in basal activity; 19.7% decrease in maximal activity). These results suggest that the desensitization of $A_1$ adenosine receptors following chronic administration involves agonist-induced uncoupling of the receptors from G proteins rather than alteration of $A_1$ adenosine receptor molecules. It is also suggested that the determination of stimulation of $[^{35}S]GTP_{\gamma}S$ binding to G proteins is a suitable tool in studying the receptor regulation including desensitization

  • PDF

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

Effect of Surface Modification by Friction Stir Process on Overlap Welded Inconel 718 Alloy (육성용접된 Inconel 718 합금의 마찰교반을 이용한 개질처리 효과)

  • Song, Kuk Hyun;Hong, Do Hyeong;Yang, Byung Mo
    • Korean Journal of Materials Research
    • /
    • v.23 no.9
    • /
    • pp.501-509
    • /
    • 2013
  • To evaluate the development of the microstructure and mechanical properties on surface modified and post-heattreated Inconel 718 alloy, this study was carried out. A friction stir process as a surface modification method was employed, and overlap welded Inconel 718 alloy as an experimental material was selected. The friction stir process was carried out at a tool rotation speed of 200 rpm and tool down force of 19.6-39.2 kN; post-heat-treatment with two steps was carried out at $720^{\circ}C$ for 8 h and $620^{\circ}C$ for 6 h in vacuum. To prevent the surface oxidation of the specimen, the method of using argon gas as shielding was utilized during the friction stir process. As a result, applying the friction stir process was effective to develop the grain refinement accompanied by dynamic recrystallization, which resulted in enhanced mechanical properties as compared to the overlap welded material. Furthermore, the post-heat-treatment after the friction stir process accelerated the formation of precipitates, such as gamma prime (${\gamma}^{\prime}$) and MC carbides, which led to the significant improvement of mechanical properties. Consequently, the microhardness, yield, and tensile strengths of the post-heat-treated material were increased more than 110%, 124% and 85 %, respectively, relative to the overlap welded material. This study systematically examined the relationship between precipitates and mechanical properties.

Effects of Gas Flow Ratio on the Properties of Tool Steel Treated by a Direct Current Flasma Nitriding Process

  • Jang H. K.;Whang C. N.;Kim S. G.;Yu B. G.
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.5
    • /
    • pp.202-206
    • /
    • 2005
  • Nitriding treatments were conducted on tool steel (SKD 61) at a temperature of $500^{\circ}C$ for 5 hr using high vacuum direct current (DC) plasma, with ammonia and argon as source gases. The structural and compositional changes produced in the nitrided layers by applying different ratios of Ar to $NH_{3}\;(n_{Ar}/n_{NH3}) were investigated using glancing x-ray diffraction (GXRD), optical microscopy, atomic force microscopy (AFM), micro-Vickers hardness testing, and pin-on-disc type tribometer. Nitriding case depths of around of $50{\mu}m$ were produced, varying slightly with different ratios of $n_{Ar}/n_{NH3}. It was found that the specimen surface hardness was 1150 Hv with $n_{Ar}/n_{NH3}=1, increasing to a maximum value of 1500 Hv with $n_{Ar}/n_{NH3}=5. With a further increase in ratio to $n_{Ar}/n_{NH3}=10, the surface hardness of the specimen reduced slightly to a value of 1370 Hv. These phenomena were caused by changes of the crystallographic structure of the nitride layers, i.e the $\gamma'-Fe_{4}N$ phase only was observed in the sample treated with $n_{Ar}/n_{NH3}$=1, and the intensity of the $\gamma'-Fe_{4}N$ phase were reduced but new phase of $\varepsilon'-Fe_{3}N$, which was known as a high hardness, with increasing $n_{Ar}/n_{NH3}. Also, the relative weight loss of counterface of the pin-on-disc with unnitrided steel was 0.2. And that of nitrided steel at a gas mixture ($n_{Ar}/n_{NH3}) of 1, 5, 7, and 10 was 0.4, 0.7, 0.6, and 0.5 mg, respectively. This means that the wear resistance of the nitrided samples could be increased by a factor of 2 at least than that of unnitrided steel.