• Title/Summary/Keyword: gamma test

Search Result 1,070, Processing Time 0.023 seconds

The Development of Beam Profiling System for the Analysis of Pulsed Gamma-ray Using the Electron Accelerator (전자빔가속기를 이용한 펄스감마선 출력특성 분석용 빔프로파일링 장치개발)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2410-2416
    • /
    • 2016
  • Recently, most countries in the world have pursued a denuclearization. So it has been of interest to increase to Nuclear weapon in such as North Korea's continued nuclear test. Pulsed gamma rays produced in the nuclear explosion and the space environment can give the big damage to the electronic device in a very short period of time. To confirm the extent of damage of these electronic devices, pulsed gamma irradiation facility that can occur in nuclear weapon or space environment are required. In this paper, we implemented the pulsed gamma-ray detection module and analyzed output of the irradiation test. We have experimented using an electron beam accelerator research facilities in Pohang Accelerator similar conditions to equip and Nuclear weapon. As a result, we confirmed that the pulsed gamma rays emitted by the gamma radiation and electron beam conversion device. The results of this paper will contribute to improve the reliability and accuracy of studies for utilizing pulsed gamma rays.

Safety Evaluation on Mutagenicity of White Layer Cake Containing Gamma-Irradiated Egg White (감마선 조사된 난백 함유 White Layer Cake의 돌연변이원성 평가)

  • 김미정;이주운;서지현;송현파;육홍선;최정미;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.7
    • /
    • pp.1172-1175
    • /
    • 2003
  • Mutagenicity of white layer cake including 20 kGy-gamma irradiated egg white manufactured as a research on the practical approaches of gamma irradiation for the reduction of egg allergy was evaluated by Salmonella typhimurium reversion assay (Ames test). The water-soluble and organic solvents mixture of methanol: chloroform (2 : 1)-soluble fractions of the white layer cake including 20 kGy-gamma irradiated egg white were examined in S. typhimurium TA98 and TA100. Both with and without metabolic activation, the number of revertant colonies were not increased in each extract compared with negative controls. No significant difference in the formation of the colonies was observed at the non-irradiated and 20 kGy-irradiated samples. The results indicate that there is no evidence of mutagenicity in white layer cake including 20 kGy-gamma irradiated egg white.

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.

Impact of gamma radiation on 8051 microcontroller performance

  • Charu Sharma;Puspalata Rajesh;R.P. Behera;S. Amirthapandian
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4422-4430
    • /
    • 2022
  • Studying the effects of gamma radiation on the instrumentation and control (I&C) system of a nuclear power plant is critical to the successful and reliable operation of the plant. In the accidental scenario, the adverse environment of ionizing radiation affects the performance of the I&C system and it leads to inaccurate and incomprehensible results. This paper reports the effects of gamma radiation on the AT89C51RD2, a commercial-off-the-shelf 8-bit high-performance flash microcontroller. The microcontroller, selected for the device under test for this study is used in the remote terminal unit for a nuclear power plant. The custom circuits were made to test the microcontroller under different gamma doses using a 60Co gamma source in both ex-situ and in-situ modes. The device was exposed to a maximum dose of 1.5 kGy. Under this hostile environment, the performance of the microcontroller was studied in terms of device current and voltage changes. It was observed that the microcontroller device can operate up to a total absorbed dose of approximately 0.6 kGy without any failure or degradation in its performance.

The Usefulness of Pleural IFN-$\gamma$ Level in Differential Diagnosis of Tuberculous Pleural Effusion and Malignant Pleural Effusion (결핵성 흉막염과 악성 흉수의 감별진단에 있어서 흉수 IFN-$\gamma$ 측정의 유용성)

  • Kim, Myung-Sun;Yang, Sung-Eun;Chi, Hyun-Sook;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.280-289
    • /
    • 1998
  • Background: It is sometimes difficult to differentiate tuberculous pleural effusion from malignant pleural effusion by clinical symptoms, signs, by routine tests of pleural fluid, and by pathologic studies. And recently, it was discovered that cytokines such as IL-2, IFN-$\gamma$, TNF-$\alpha$ are elevated in tuberculous pleural fluid, and there have been several attempts to diagnose tuberculous pleural effusion by using these immunological mediators. There are several studies regarding the diagnostic value of IFN-$\gamma$, and there are two studies in Korea. But the diagnostic values of IFN-$\gamma$ in these studies were slightly lower than those in other countries. To compare the diagnostic value of IFN-$\gamma$ with those of CEA and ADA, and to determine the sensitivity and specificity of IFN-$\gamma$ in Korean, we mesured IFN-$\gamma$, CEA level and ADA activity in pleural effusions. Methods: ADA activity, IFN-$\gamma$ level and CEA level as well as cell count, differential count, and biochemical assays such as protein content and lactate dehydrogenase were measured in 40 cases of tuberculous pleuritis and 42 cases of malignant pleural effusion. Results: Tuberculous pleural fluid showed higher levels of IFN-$\gamma$ and ADA ($832.6{\pm}357.2$ pg/ml and $82.5{\pm}25.9$ U/L, respectively) than those of malignant pleural effusion ($2.6{\pm}8.0$ pg/ml and $19.2{\pm}10.9$ U/L, respectively) (p<0.01). Malignant pleural effusions showed higher median value (102.2 ng/ml) than tubercalous pleural effusions (1.8 ng/ml) (p<0.01). The sensitivities of IFN-$\gamma$, ADA, CEA were 0.97, 0.87, 0.67 and the specificities of IFN-$\gamma$, ADA, CEA were 1.0, 0.97, 1.0, respectively. There was no significant correlation between ADA activity and IFN-$\gamma$ level. Conclusion: This study showed that IFN-$\gamma$ test would be a very useful clinical test for differential diagnosis of tuberculous pleuritis and malignant pleural effusion because it is very sensitive and specific, although it is an expensive test.

  • PDF

Development of Automatic Gamma Optimization System for Mobile TFT-LCD (DSP를 이용한 모바일 TFT-LCD의 자동 감마 최적화 시스템 개발)

  • Cho, Nae-Soo;Ryu, Jee-Youl;Park, Chul-Woo;Kwon, Woo-Hyen
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.323-329
    • /
    • 2009
  • This paper presents an automatic LCD gamma control system using gamma curve optimization. It controls automatically gamma adjustment registers in mobile LCD driver IC to reduce gamma correction error and adjusting time. The proposed gamma system contains Module-Under-Test (MUT, LCD module), PC installed with program, multimedia display tester for measuring luminance, and control board for interface between PC and LCD module. Proposed algorithm and program are applicable for most of the LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic gamma control system showed significantly reduced gamma adjusting time of 240 sec. and much less average gamma error of 11% than 42h and 27% with conventional manual method. We believe that the proposed system is very useful to provide high-quality LCD and to improve production process.

The Meaning of P50 Suppression : Interaction of Gamma and Alpha Waves

  • Lee, Kyungjun;Kang, Ung Gu
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.4
    • /
    • pp.168-174
    • /
    • 2014
  • Objectives Sensory gating dysfunctions in patients with schizophrenia and bipolar disorder have been investigated through two similar methods ; P50 suppression and prepulse inhibition paradigms. However, recent studies have demonstrated that the two measures are not correlated but rather constitute as distinct neural processes. Recent studies adopting spectral frequency analysis suggest that P50 suppression reflects the interaction between gamma and other frequency bands. The aim of the present study is to investigate which frequency component shows more significant interaction with gamma band. Methods A total of 108 mood disorder patients and 36 normal subjects were included in the study. The P50 responses to conditioning and test stimuli with an intra-pair interval of 500 msec were measured in the study population. According to P50 ratio (amplitude to the test stimulus/amplitude to the conditioning stimulus), the subjects with P50 ratio less than 0.2 were defined as suppressed group (SG) ; non-suppressed group (NSG) consisted of P50 ratio more than 0.8. Thirty-five and 25 subjects were included in SG and NSG, respectively. Point-to-point correlation coefficients (PPCCs) of both groups were calculated between two time-windows : the first window (S1) was defined as the time-window of one hundred millisecond after the conditioning auditory stimulus and the second window (S2) was defined as the time-window of 100 msec after the test auditory stimulus. Spectral frequency analysis was performed to investigate which frequency band results in the difference of PPCC between SG and NSG. Results Significant reduction of PPCC between S1 and S2 was observed in the SG (Pearson's r = 0.24), compared to PPCC of the NSG (r = 0.58, p < 0.05). In spectral frequency analysis, gamma band showed "phase-reset" and similar responses after the two auditory stimuli in suppressed and non-suppressed group. However in the case of alpha band, comparison showed significantly low PPCC in SG (r = -0.14) compared to NSG (r = 0.36, p < 0.05). This may be reflecting "phase-out" of alpha band against gamma band at approximately 50 msecs after the test stimulus in the SG. Conclusions Our study suggests that normal P50 suppression is caused by phase-out of alpha band against gamma band after the second auditory stimulus. Thus it is demonstrated that normal sensory gating process is constituted with attenuated alpha power, superimposed on consistent gamma response. Implications of preserved gamma and decreased alpha band in sensory gating function are discussed.

Genotoxicological Safety of the Gamma Irradiated Medicinal Herbs in the salmonella typhimurium Reversion Assay (복귀돌연변이시험을 이용한 감마선조사 생약재의 안전성에 관한 유전독성학적 평가)

  • 조성기;육홍선;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.5
    • /
    • pp.958-964
    • /
    • 1997
  • The three medicinal herbs-Curcuma longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays have been tested for their possible genotoxicity. The methanol-soluble and water-soluble fractions of the 10kGy gamma-iradiated herbs were examined in the Salmonella typhimurium histidine reversion assy(Ames test) using S. typhimurium TA98, TA100 and TA102 as tester strains. No mutabenicity was detected in this assay with or without metabolic activation. The safety of the herbs irradiated with gamma rays at practical doses needs to be evaluated in further tests of genotoxicity in vivo and chronic and reproductive toxicity.

  • PDF

Corrsion of Ni-Ze Electrodeposited Alloy (아연-니켈합금 전기도금층의 부식특성)

  • 예길촌;신현준
    • Journal of the Korean institute of surface engineering
    • /
    • v.21 no.2
    • /
    • pp.39-46
    • /
    • 1988
  • Corrosion behavior of 5-26wt% Ni-Zn electrodeposited alloys was investigated by means of dipping electrochmical polarization measurement and galvanic coupling test. The weight loss and anodic polarization curve of coatings were measured by means of dipping and polarization measurement respectively. The galvanic protection effect of alloy coatings was measured by galvanic coupling test and the surface morpholgy of coatings was observed after corrosion testing. Our findings support thous of previous investigations showing that ${\gamma}$single phase coatings, while galvanic pprotection effect of dual phase coatings improved in comparison with ${\gamma}$single phase coating. The formation of colony in coating of ${\gamma}$and η+${\gamma}$ dual phsae caused the localized corrsion and increased the corrosion rate of the Ni-Zn coating.

  • PDF

Rao-Wald Test for Variance Ratios of a General Linear Model

  • Li, Seung-Chun;Huh, Moon-Yul
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.1
    • /
    • pp.11-24
    • /
    • 1999
  • In this paper we propose a method to test $\textit{H}$:$\rho_i$=$\gamma_i$ for 1$\leq$$\textit{i}$$\leq$$\ell$ against $\textit{K}$:$\rho_i$$\neq$$\gamma_i$ for some iin k-variance component random or mixed linear model where $\rho$i denotes the ratio of the i-th variance component to the error variance and $\ell$$\leq$K. The test which we call Rao-Wald test is exact and does not depend upon nuisance parameters. From a numerical study of the power performance of the test of the interaction effect for the case of a two-way random model Rao-Wald test was seen to be quite comparable to the locally best invariant (LBI) test when the nuisance parameters of the LBI test are assumed known. When the nuisance parameters of the LBI test are replaced by maximum likelihood estimators Rao-Wald test outperformed the LBI test.

  • PDF